These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 33732834)

  • 41. Oxidized Zirconium Bearing Surfaces in Total Knee Arthroplasty: Lessons Learned.
    Schüttler KF; Efe T; Heyse TJ; Haas SB
    J Knee Surg; 2015 Oct; 28(5):376-81. PubMed ID: 26216647
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Revision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy. A case report.
    Van Opstal N; Verheyden F
    Acta Orthop Belg; 2011 Oct; 77(5):691-5. PubMed ID: 22187849
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study.
    Koff MF; Gao MA; Neri JP; Chiu YF; Lin BQ; Burge AJ; Su E; Padgett DE; Potter HG
    Clin Orthop Relat Res; 2021 Dec; 479(12):2633-2650. PubMed ID: 34232144
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Oxidized zirconium femoral component for TKA: a follow-up note of a previous report at a minimum of 10 years.
    Innocenti M; Matassi F; Carulli C; Nistri L; Civinini R
    Knee; 2014 Aug; 21(4):858-61. PubMed ID: 24835580
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.
    Zaoui A; Hage SE; Langlois J; Scemama C; Courpied JP; Hamadouche M
    Clin Orthop Relat Res; 2015 Dec; 473(12):3822-8. PubMed ID: 26113111
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Five-year comparison of oxidized zirconium and cobalt-chromium femoral components in total knee arthroplasty: a randomized controlled trial.
    Hui C; Salmon L; Maeno S; Roe J; Walsh W; Pinczewski L
    J Bone Joint Surg Am; 2011 Apr; 93(7):624-30. PubMed ID: 21471415
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.
    Kim YH; Kim JS; Huh W; Lee KH
    Clin Orthop Relat Res; 2010 May; 468(5):1296-304. PubMed ID: 19949906
    [TBL] [Abstract][Full Text] [Related]  

  • 49. An Interesting Case of Osteolysis With Accompanying Metallosis in a Primary Total Knee Arthroplasty.
    Lamba C; Denning K; Ouellette E; Kurtz S; Bullock M
    Arthroplast Today; 2021 Oct; 11():81-87. PubMed ID: 34485655
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Similarly low blood metal ion levels at 10-years follow-up of total hip arthroplasties with Oxinium, CoCrMo, and stainless steel femoral heads. Data from a randomized clinical trial.
    Høl PJ; Hallan G; Furnes O; Fenstad AM; Indrekvam K; Kadar T
    J Biomed Mater Res B Appl Biomater; 2023 Apr; 111(4):821-828. PubMed ID: 36356214
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Ceramic-on-Ceramic or Metal-on-Polyethylene: The Bearing of Choice after Ceramic Component Fracture in Total Hip Arthroplasty along with Concise Follow-Up of the Previous Cohort.
    Kim HS; Lee HJ; Lee SJ; Yoo JJ
    Orthop Surg; 2023 Nov; 15(11):2864-2871. PubMed ID: 37749775
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Arthroplasty options for the young patient: Oxinium on cross-linked polyethylene.
    Bourne RB; Barrack R; Rorabeck CH; Salehi A; Good V
    Clin Orthop Relat Res; 2005 Dec; 441():159-67. PubMed ID: 16330999
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components.
    White SE; Whiteside LA; McCarthy DS; Anthony M; Poggie RA
    Clin Orthop Relat Res; 1994 Dec; (309):176-84. PubMed ID: 7994957
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Early to mid-term outcome of Oxinium on Verilast highly cross-linked polyethylene bearing surface in uncemented total hip arthroplasty.
    Sobti AS; Busch CA; Afolayan JO; Michael D; Chana R
    Hip Int; 2019 Nov; 29(6):660-664. PubMed ID: 30630363
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Tribocorrosion: Ceramic and Oxidized Zirconium vs Cobalt-Chromium Heads in Total Hip Arthroplasty.
    Tan SC; Lau AC; Del Balso C; Howard JL; Lanting BA; Teeter MG
    J Arthroplasty; 2016 Sep; 31(9):2064-71. PubMed ID: 27067752
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty.
    Buckner BC; Urban ND; Cahoy KM; Lyden ER; Deans CF; Garvin KL
    Bone Joint J; 2024 Mar; 106-B(3 Supple A):38-43. PubMed ID: 38423114
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Protrusion of a ceramic femoral head through the acetabular metallic cup in total-hip arthroplasty: A case report.
    Zhao D; Zhang DB; Han DF; Gu GS
    Medicine (Baltimore); 2020 Jun; 99(24):e20469. PubMed ID: 32541468
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review.
    Kovochich M; Finley BL; Novick R; Monnot AD; Donovan E; Unice KM; Fung ES; Fung D; Paustenbach DJ
    Crit Rev Toxicol; 2018 Nov; 48(10):853-901. PubMed ID: 30912993
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants.
    Skjöldebrand C; Tipper JL; Hatto P; Bryant M; Hall RM; Persson C
    Mater Today Bio; 2022 Jun; 15():100270. PubMed ID: 35601891
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Wear of polyethylene against oxidized zirconium femoral components effect of aggressive kinematic conditions and malalignment in total knee arthroplasty.
    Ezzet KA; Hermida JC; Steklov N; D'Lima DD
    J Arthroplasty; 2012 Jan; 27(1):116-21. PubMed ID: 21908170
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.