BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 33746176)

  • 1. [An Evaluation of Radiation Dose for Wide Volume Scan during Chest CT].
    Sako K; Matsubara K; Matsumoto M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2021; 77(3):284-292. PubMed ID: 33746176
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiation dose dependence on subject size in abdominal computed tomography: Water phantom and patient model comparison.
    Li X; Yang K; Liu B
    Med Phys; 2018 May; 45(5):2309-2317. PubMed ID: 29582439
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Novel Method to Extend a Partial-Body CT for the Reconstruction of Dose to Organs beyond the Scan Range.
    Kuzmin GA; Mille MM; Jung JW; Lee C; Pelletier C; Akabani G; Lee C
    Radiat Res; 2018 Jun; 189(6):618-626. PubMed ID: 29617205
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Organ doses evaluation for chest computed tomography procedures with TL dosimeters: Comparison with Monte Carlo simulations.
    Giansante L; Martins JC; Nersissian DY; Kiers KC; Kay FU; Sawamura MVY; Lee C; Gebrim EMMS; Costa PR
    J Appl Clin Med Phys; 2019 Jan; 20(1):308-320. PubMed ID: 30508315
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization and implementation of OSL dosimeters for use in evaluating the efficacy of organ-based tube current modulation for CT scans of the face and orbits.
    Marsh RM; Silosky M
    Med Phys; 2015 Apr; 42(4):1730-8. PubMed ID: 25832062
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Chest CT performed with 3D and z-axis automatic tube current modulation technique: breast and effective doses.
    Matsubara K; Takata T; Koshida K; Noto K; Shimono T; Horii J; Yamamoto T; Matsui O
    Acad Radiol; 2009 Apr; 16(4):450-5. PubMed ID: 19268857
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wide-volume versus helical acquisition in unenhanced chest CT: prospective intra-patient comparison of diagnostic accuracy and radiation dose in an ultra-low-dose setting.
    Meyer E; Labani A; Schaeffer M; Jeung MY; Ludes C; Meyer A; Roy C; Leyendecker P; Ohana M
    Eur Radiol; 2019 Dec; 29(12):6858-6866. PubMed ID: 31175414
    [TBL] [Abstract][Full Text] [Related]  

  • 8. DEVELOPMENT OF A JAPANESE INFANT HEAD-CHEST PHANTOM AND INVESTIGATION OF THE CURRENT STATUS OF INFANT HEAD CT EXAMINATIONS IN JAPAN.
    Yamauchi-Kawaura C; Fujii K; Yamauchi M; Imai K; Ikeda M; Narai K; Shimizu H
    Radiat Prot Dosimetry; 2020 Jun; 188(1):65-72. PubMed ID: 31836891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic exposure control in pediatric and adult computed tomography examinations: can we estimate organ and effective dose from mean MAS reduction?
    Papadakis AE; Perisinakis K; Oikonomou I; Damilakis J
    Invest Radiol; 2011 Oct; 46(10):654-62. PubMed ID: 21673583
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiation exposure dose outside the irradiation field due to differences in pediatric head computed tomography scanning methods.
    Higuchi K; Fujimura T
    Radiol Phys Technol; 2021 Jun; 14(2):173-178. PubMed ID: 33783725
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inaccurate table height setting affects the organ-specific radiation dose in computed tomography.
    Ishita Y; Urikura A; Yoshida T; Takiguchi K; Ikegaya M
    Eur J Radiol; 2022 Jun; 151():110317. PubMed ID: 35468445
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.
    Brisse HJ; Robilliard M; Savignoni A; Pierrat N; Gaboriaud G; De Rycke Y; Neuenschwander S; Aubert B; Rosenwald JC
    Health Phys; 2009 Oct; 97(4):303-14. PubMed ID: 19741359
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of radiation dose estimates and scan performance in pediatric high-resolution thoracic CT for volumetric 320-detector row, helical 64-detector row, and noncontiguous axial scan acquisitions.
    Podberesky DJ; Angel E; Yoshizumi TT; Toncheva G; Salisbury SR; Brody AS; Alsip C; Barelli A; Egelhoff JC; Anderson-Evans C; Nguyen GB; Dow D; Frush DP
    Acad Radiol; 2013 Sep; 20(9):1152-61. PubMed ID: 23931430
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.
    Tzedakis A; Damilakis J; Perisinakis K; Stratakis J; Gourtsoyiannis N
    Med Phys; 2005 Jun; 32(6):1621-9. PubMed ID: 16013721
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of beam collimation of z-overscanning on dose to the lens and thyroid gland in paediatric thoracic computed tomography imaging.
    Masuda T; Kiguchi M; Fujioka C; Oku T; Ishibashi T; Katsunuma Y; Yoshitake T; Abe S; Awai K
    Pediatr Radiol; 2024 May; 54(5):758-763. PubMed ID: 38308740
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effectiveness of bismuth breast shielding with protocol optimization in CT Thorax examination.
    Karim MKA; Rahim NA; Matsubara K; Hashim S; Mhareb MHA; Musa Y
    J Xray Sci Technol; 2019; 27(1):139-147. PubMed ID: 30584178
    [TBL] [Abstract][Full Text] [Related]  

  • 17. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm.
    Li X; Zhang D; Liu B
    Med Phys; 2015 Jun; 42(6):2882-91. PubMed ID: 26127041
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications.
    Busse N; Erwin W; Pan T
    Med Phys; 2013 Dec; 40(12):122503. PubMed ID: 24320539
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of radiation dose from tube current modulated CT examinations with considerations of both patient size and variable tube current.
    Li X; Yang K; Liu B
    Med Phys; 2017 Oct; 44(10):5413-5422. PubMed ID: 28681439
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current.
    Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
    Med Phys; 2011 Nov; 38(11):6084-92. PubMed ID: 22047373
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.