These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 33752341)

  • 1. Sensitivity of sum frequency generation experimental conditions to thin film interference effects.
    Cotton DE; Roberts ST
    J Chem Phys; 2021 Mar; 154(11):114704. PubMed ID: 33752341
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nondestructive in situ characterization of molecular structures at the surface and buried interface of silicon-supported low-k dielectric films.
    Myers JN; Zhang X; Bielefeld J; Lin Q; Chen Z
    J Phys Chem B; 2015 Jan; 119(4):1736-46. PubMed ID: 25558913
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Interference effects in the sum frequency generation spectra of thin organic films. I. Theoretical modeling and simulation.
    Tong Y; Zhao Y; Li N; Osawa M; Davies PB; Ye S
    J Chem Phys; 2010 Jul; 133(3):034704. PubMed ID: 20649347
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interference effects in the sum frequency generation spectra of thin organic films. II: Applications to different thin-film systems.
    Tong Y; Zhao Y; Li N; Ma Y; Osawa M; Davies PB; Ye S
    J Chem Phys; 2010 Jul; 133(3):034705. PubMed ID: 20649348
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Demonstrating the feasibility of monitoring the molecular-level structures of moving polymer/silane interfaces during silane diffusion using SFG.
    Chen C; Wang J; Loch CL; Ahn D; Chen Z
    J Am Chem Soc; 2004 Feb; 126(4):1174-9. PubMed ID: 14746487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Molecular Structure and Modeling of Water-Air and Ice-Air Interfaces Monitored by Sum-Frequency Generation.
    Tang F; Ohto T; Sun S; Rouxel JR; Imoto S; Backus EHG; Mukamel S; Bonn M; Nagata Y
    Chem Rev; 2020 Apr; 120(8):3633-3667. PubMed ID: 32141737
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chemical Imaging of Surfaces with Sum Frequency Generation Vibrational Spectroscopy.
    Shah SA; Baldelli S
    Acc Chem Res; 2020 Jun; 53(6):1139-1150. PubMed ID: 32437170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Unified treatment and measurement of the spectral resolution and temporal effects in frequency-resolved sum-frequency generation vibrational spectroscopy (SFG-VS).
    Velarde L; Wang HF
    Phys Chem Chem Phys; 2013 Dec; 15(46):19970-84. PubMed ID: 24076622
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sum-frequency generation at interfaces: A Fresnel story. I. Designing high contrast in two interface systems.
    Busson B
    J Chem Phys; 2023 Jul; 159(3):. PubMed ID: 37462289
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Robust Self-Referencing Method for Chiral Sum Frequency Generation Spectroscopy.
    McDermott ML; Petersen PB
    J Phys Chem B; 2015 Sep; 119(38):12417-23. PubMed ID: 26322867
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diffusion of one or more components of a silane adhesion-promoting mixture into poly(methyl methacrylate).
    Loch CL; Ahn D; Vázquez AV; Chen Z
    J Colloid Interface Sci; 2007 Apr; 308(1):170-5. PubMed ID: 17214999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The structure of oleamide films at the aluminum/oil interface and aluminum/air interface studied by Sum Frequency Generation (SFG) vibrational spectroscopy and Reflection Absorption Infrared Spectroscopy (RAIRS).
    Casford MT; Davies PB
    ACS Appl Mater Interfaces; 2009 Aug; 1(8):1672-81. PubMed ID: 20355782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Consistency in the sum frequency generation intensity and phase vibrational spectra of the air/neat water interface.
    Feng RR; Guo Y; Lü R; Velarde L; Wang HF
    J Phys Chem A; 2011 Jun; 115(23):6015-27. PubMed ID: 21306145
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of single-channel heterodyne-detected sum frequency generation spectroscopy and its application to the water/vapor interface.
    Yamaguchi S
    J Chem Phys; 2015 Jul; 143(3):034202. PubMed ID: 26203020
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative study of direct and phase-specific vibrational sum-frequency generation spectroscopy: advantages and limitations.
    Pool RE; Versluis J; Backus EH; Bonn M
    J Phys Chem B; 2011 Dec; 115(51):15362-9. PubMed ID: 22074616
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sample cells for probing solid/liquid interfaces with broadband sum-frequency-generation spectroscopy.
    Verreault D; Kurz V; Howell C; Koelsch P
    Rev Sci Instrum; 2010 Jun; 81(6):063111. PubMed ID: 20590229
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrafast nonlinear coherent vibrational sum-frequency spectroscopy methods to study thermal conductance of molecules at interfaces.
    Carter JA; Wang Z; Dlott DD
    Acc Chem Res; 2009 Sep; 42(9):1343-51. PubMed ID: 19388671
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigating Bénard-Marangoni migration at the air-water interface in the time domain using sum frequency generation (SFG) spectroscopy of palmitic acid monolayers.
    Fellows AP; Casford MTL; Davies PB
    J Chem Phys; 2022 Apr; 156(16):164701. PubMed ID: 35490017
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lamellar orientation at the surface of isotactic polystyrene thin films analyzed by sum frequency generation spectroscopy.
    de Lima BM; Hayes PL; Wood-Adams PM
    Anal Chim Acta; 2023 Apr; 1248():340904. PubMed ID: 36813456
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simulated vibrational sum frequency generation from a multilayer thin film system with two active interfaces.
    O'Brien DB; Massari AM
    J Chem Phys; 2013 Apr; 138(15):154708. PubMed ID: 23614437
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.