These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 33775930)

  • 41. A randomised comparison of Conventional versus Intentional straTegy in patients with high Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion: rationale and design of the CIT-RESOLVE trial.
    Zhang D; Yin D; Song C; Zhu C; Kirtane AJ; Xu B; Dou K
    BMJ Open; 2017 Jun; 7(6):e016044. PubMed ID: 28606906
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Sequential vs. kissing balloon angioplasty for stenting of bifurcation coronary lesions.
    Brueck M; Scheinert D; Flachskampf FA; Daniel WG; Ludwig J
    Catheter Cardiovasc Interv; 2002 Apr; 55(4):461-6. PubMed ID: 11948892
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions.
    Hakim D; Chatterjee A; Alli O; Turner J; Sattar A; Foin N; Leesar MA
    Circ Cardiovasc Interv; 2017 Oct; 10(10):. PubMed ID: 29038225
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A modified balloon crush approach improves side branch access and side branch stent apposition during crush stenting of coronary bifurcation lesions.
    Collins N; Dzavik V
    Catheter Cardiovasc Interv; 2006 Sep; 68(3):365-71. PubMed ID: 16892432
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Double kissing inflation outside the stent secures the patency of small side branch without rewiring.
    Yang H; Song Y; Cao J; Weng X; Zhang F; Dai Y; Lu H; Li C; Huang Z; Qian J; Ge J
    BMC Cardiovasc Disord; 2021 May; 21(1):232. PubMed ID: 33962571
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Effectiveness of the proximal optimization technique for longitudinal stent elongation caused by post-balloon dilatation.
    Matsuda Y; Ashikaga T; Sasaoka T; Hatano Y; Umemoto T; Yamamoto T; Maejima Y; Hirao K
    J Interv Cardiol; 2018 Oct; 31(5):624-631. PubMed ID: 29989210
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Mini- versus classical kissing balloon inflation in provisional technique for bifurcation intervention.
    Liu J; Chen S; Wei J; Zeng F; Li L
    J Interv Cardiol; 2018 Dec; 31(6):755-764. PubMed ID: 30069984
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Segmental comparison between a dedicated bifurcation stent and balloon angioplasty using intravascular ultrasound and three-dimensional quantitative coronary angiography: A subgroup analysis of the Tryton IDE randomized trial.
    Grundeken MJ; Garcia-Garcia HM; Kumsars I; Lesiak M; Kayaert P; Dens J; Stella PR; de Winter RJ; Laak LL; Généreux P; Kaplan AV; Leon MB; Wykrzykowska JJ; Onuma Y; Serruys PW
    Catheter Cardiovasc Interv; 2017 Feb; 89(2):E53-E63. PubMed ID: 27083384
    [TBL] [Abstract][Full Text] [Related]  

  • 50. The Cone Flare Crush Modified-T (CFCT) stenting technique for coronary artery bifurcation lesions.
    Peverill WT; Incani A; Worthley SG; Singbal Y; Garrahy PJ; McCann AB; Cox SV; Moore PT; Lim RYY; Fetahovic T; Connors GW; Hall C; Sieg C; Camuglia AC
    Int J Cardiol Heart Vasc; 2020 Oct; 30():100643. PubMed ID: 33015315
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Toward a sequential provisional coronary bifurcation stenting technique. From kissing balloon to re-POT sequence.
    Dérimay F; Rioufol G; Aminian A; Maillard L; Finet G
    Arch Cardiovasc Dis; 2020 Mar; 113(3):199-208. PubMed ID: 32008946
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Randomized comparison between provisional and routine kissing-balloon technique after main vessel crossover stenting for coronary bifurcation lesions.
    Yamawaki M; Fujita M; Sasaki S; Tsurugida M; Nanasato M; Araki M; Hirano K; Ito Y; Tsukahara R; Muramatsu T;
    Heart Vessels; 2017 Sep; 32(9):1067-1076. PubMed ID: 28401352
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Modified crush technique with double kissing balloon inflation (sleeve technique): a novel technique for coronary bifurcation lesions.
    Jim MH; Ho HH; Miu R; Chow WH
    Catheter Cardiovasc Interv; 2006 Mar; 67(3):403-9. PubMed ID: 16489571
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Standardized fractal bench test evaluation of coronary stents: Performances in bifurcation lesions treated by the re-proximal optimization technique.
    Piriou PG; Bonin M; Huchet F; Letocart V; Manigold T; Plessis J; Derimay F; Veziers J; Jordana F; Guerin P
    Catheter Cardiovasc Interv; 2021 Jul; 98(1):E9-E17. PubMed ID: 32966675
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Benefits of final proximal optimization technique (POT) in provisional stenting.
    Dérimay F; Rioufol G; Cellier G; Souteyrand G; Finet G
    Int J Cardiol; 2019 Jan; 274():71-73. PubMed ID: 30236500
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Sequential Proximal Optimizing Technique in Provisional Bifurcation Stenting With Everolimus-Eluting Bioresorbable Vascular Scaffold: Fractal Coronary Bifurcation Bench for Comparative Test Between Absorb and XIENCE Xpedition.
    Derimay F; Souteyrand G; Motreff P; Guerin P; Pilet P; Ohayon J; Darremont O; Rioufol G; Finet G
    JACC Cardiovasc Interv; 2016 Jul; 9(13):1397-406. PubMed ID: 27388830
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Bifurcation percutaneous coronary intervention of left main trunk treated using a proximal optimizing technique and proximal balloon edge dilation technique.
    Kume T; Koto S; Sudo Y; Hiroshi O; Yamada R; Imai K; Koyama T; Tamada T; Neishi Y; Uemura S
    J Cardiol Cases; 2022 Jan; 25(1):30-33. PubMed ID: 35024065
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Optical coherence tomography assessment of a new dedicated bifurcation stent.
    Tyczynski P; Ferrante G; Kukreja N; Moreno-Ambroj C; Barlis P; Ramasami N; De Silva R; Beatt K; Di Mario C
    EuroIntervention; 2009 Nov; 5(5):544-51. PubMed ID: 20142174
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Usability of Fantom Encore® scaffold in non-complex bifurcations-Analysis in bench models.
    G Toth G; Ono M; Buschmann E; Wu X; Edl D; Onuma Y; Serruys PW; Wijns W
    Catheter Cardiovasc Interv; 2022 Feb; 99(2):424-432. PubMed ID: 33565719
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Double Kissing Crush Versus Provisional Stenting for Left Main Distal Bifurcation Lesions: DKCRUSH-V Randomized Trial.
    Chen SL; Zhang JJ; Han Y; Kan J; Chen L; Qiu C; Jiang T; Tao L; Zeng H; Li L; Xia Y; Gao C; Santoso T; Paiboon C; Wang Y; Kwan TW; Ye F; Tian N; Liu Z; Lin S; Lu C; Wen S; Hong L; Zhang Q; Sheiban I; Xu Y; Wang L; Rab TS; Li Z; Cheng G; Cui L; Leon MB; Stone GW
    J Am Coll Cardiol; 2017 Nov; 70(21):2605-2617. PubMed ID: 29096915
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.