123 related articles for article (PubMed ID: 33777756)
41. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy. Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431 [TBL] [Abstract][Full Text] [Related]
42. Dosimetric characterization of the iBEAM evo carbon fiber couch for radiotherapy. Smith DW; Christophides D; Dean C; Naisbit M; Mason J; Morgan A Med Phys; 2010 Jul; 37(7):3595-606. PubMed ID: 20831067 [TBL] [Abstract][Full Text] [Related]
43. A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy. Saenz DL; Astorga NR; Kirby N; Fakhreddine M; Rasmussen K; Stathakis S; Papanikolaou N J Appl Clin Med Phys; 2018 Sep; 19(5):625-631. PubMed ID: 30085393 [TBL] [Abstract][Full Text] [Related]
44. Assessment of an Elekta Versa HD linear accelerator for stereotactic radiosurgery with circular cone collimators. Zhang M; Fan Q; Lei Y; Thapa B; Padula G J Xray Sci Technol; 2020; 28(1):71-82. PubMed ID: 31904001 [TBL] [Abstract][Full Text] [Related]
45. Dosimetric aspects of inverse-planned modulated-arc total-body irradiation. Held M; Kirby N; Morin O; Pouliot J Med Phys; 2012 Aug; 39(8):5263-71. PubMed ID: 22894451 [TBL] [Abstract][Full Text] [Related]
46. Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Cho Y; Moseley DJ; Siewerdsen JH; Jaffray DA Med Phys; 2005 Apr; 32(4):968-83. PubMed ID: 15895580 [TBL] [Abstract][Full Text] [Related]
47. Stereotactic radiosurgery with MLC-defined arcs: Verification of dosimetry, spatial accuracy, and end-to-end tests. Brezovich IA; Wu X; Popple RA; Covington E; Cardan R; Shen S; Fiveash J; Bredel M; Guthrie B J Appl Clin Med Phys; 2019 May; 20(5):84-98. PubMed ID: 30977297 [TBL] [Abstract][Full Text] [Related]
48. New equations for matching a low neck field to oblique upper neck fields with collimator rotation in a 3-field monoisocentric setup for head-and-neck cancers. Manske MA; Barker JL; Wong PF; Westlake W; Garden AS; Ang KK; Rosenthal DI Med Dosim; 2004; 29(2):86-91. PubMed ID: 15191753 [TBL] [Abstract][Full Text] [Related]
49. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles. Zhang Y; Hsi WC; Chu JC; Bernard DB; Abrams RA J Appl Clin Med Phys; 2005; 6(2):50-61. PubMed ID: 15940212 [TBL] [Abstract][Full Text] [Related]
50. Clinical implementation of intensity-modulated arc therapy. Yu CX; Li XA; Ma L; Chen D; Naqvi S; Shepard D; Sarfaraz M; Holmes TW; Suntharalingam M; Mansfield CM Int J Radiat Oncol Biol Phys; 2002 Jun; 53(2):453-63. PubMed ID: 12023150 [TBL] [Abstract][Full Text] [Related]
51. A virtual simulator designed for collision prevention in proton therapy. Jung H; Kum O; Han Y; Park HC; Kim JS; Choi DH Med Phys; 2015 Oct; 42(10):6021-7. PubMed ID: 26429277 [TBL] [Abstract][Full Text] [Related]
52. Detection of the focal spot motion relative to the collimator axis of a linear accelerator under gantry rotation. Riis HL; Ebert MA; Rowshanfarzad P Phys Med Biol; 2019 Jan; 64(3):03NT02. PubMed ID: 30566917 [TBL] [Abstract][Full Text] [Related]
53. Collision indicator charts for gantry-couch position combinations for Varian linacs. Becker SJ J Appl Clin Med Phys; 2011 Mar; 12(3):3405. PubMed ID: 21844849 [TBL] [Abstract][Full Text] [Related]
54. Collision detection and avoidance during treatment planning. Humm JL; Pizzuto D; Fleischman E; Mohan R Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1101-8. PubMed ID: 7493836 [TBL] [Abstract][Full Text] [Related]
55. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study. Chow JC; Grigorov GN Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563 [TBL] [Abstract][Full Text] [Related]
56. Multibeam tomotherapy: a new treatment unit devised for multileaf collimation, intensity-modulated radiation therapy. Achterberg N; Müller RG Med Phys; 2007 Oct; 34(10):3926-42. PubMed ID: 17985638 [TBL] [Abstract][Full Text] [Related]
57. DeepBeam: a machine learning framework for tuning the primary electron beam of the PRIMO Monte Carlo software. Tabor Z; Kabat D; Waligórski MPR Radiat Oncol; 2021 Jun; 16(1):124. PubMed ID: 34187495 [TBL] [Abstract][Full Text] [Related]
58. A motorized solid-state phantom for patient-specific dose verification in ion beam radiotherapy. Henkner K; Winter M; Echner G; Ackermann B; Brons S; Horn J; Jäkel O; Karger CP Phys Med Biol; 2015 Sep; 60(18):7151-63. PubMed ID: 26334387 [TBL] [Abstract][Full Text] [Related]
59. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy. Létourneau D; Publicover J; Kozelka J; Moseley DJ; Jaffray DA Med Phys; 2009 May; 36(5):1813-21. PubMed ID: 19544800 [TBL] [Abstract][Full Text] [Related]
60. Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA. Olch AJ Med Phys; 2012 Jan; 39(1):81-6. PubMed ID: 22225277 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]