133 related articles for article (PubMed ID: 3378021)
1. Comparative evaluation of oculokinetic perimetry and conventional perimetry in glaucoma.
Alvarez E; Damato BE; Jay JL; McClure E
Br J Ophthalmol; 1988 Apr; 72(4):258-62. PubMed ID: 3378021
[TBL] [Abstract][Full Text] [Related]
2. Oculokinetic perimetry: a simple visual field test for use in the community.
Damato BE
Br J Ophthalmol; 1985 Dec; 69(12):927-31. PubMed ID: 4084485
[TBL] [Abstract][Full Text] [Related]
3. A new chart to improve the efficiency of glaucoma detection by oculokinetic perimetry.
Stirling RJ; MacLeod JD; Vernon SA
Eye (Lond); 1994; 8 ( Pt 1)():121-4. PubMed ID: 8013705
[TBL] [Abstract][Full Text] [Related]
4. Clinical evaluation of a multi-fixation campimeter for the detection of glaucomatous visual field loss.
Mutlukan E; Damato BE; Jay JL
Br J Ophthalmol; 1993 Jun; 77(6):332-8. PubMed ID: 8318478
[TBL] [Abstract][Full Text] [Related]
5. [Application of oculokinetic perimetry in examination of the eye].
Wakakura M; Kageyama M; Hamanaka T; Shimizu K; Joshita H; Shimizu T; Baba H; Kisara M; Miyata M
Nippon Ganka Gakkai Zasshi; 1996 Jul; 100(7):551-7. PubMed ID: 8741340
[TBL] [Abstract][Full Text] [Related]
6. Octopus 900 Automated Kinetic Perimetry versus Standard Automated Static Perimetry in Glaucoma Practice.
Rowe FJ; Czanner G; Somerville T; Sood I; Sood D
Curr Eye Res; 2021 Jan; 46(1):83-95. PubMed ID: 32564629
[No Abstract] [Full Text] [Related]
7. Eye Movement Perimetry and Frequency Doubling Perimetry: clinical performance and patient preference during glaucoma screening.
Meethal NSK; Pel JJM; Mazumdar D; Asokan R; Panday M; van der Steen J; George R
Graefes Arch Clin Exp Ophthalmol; 2019 Jun; 257(6):1277-1287. PubMed ID: 30944987
[TBL] [Abstract][Full Text] [Related]
8. Oculokinetic perimetry compared with Humphrey visual field analysis in the detection of glaucomatous visual field loss.
Wishart PK
Eye (Lond); 1993; 7 ( Pt 1)():113-21. PubMed ID: 8325400
[TBL] [Abstract][Full Text] [Related]
9. Development of a test grid using Eye Movement Perimetry for screening glaucomatous visual field defects.
Kadavath Meethal NS; Mazumdar D; Asokan R; Panday M; van der Steen J; Vermeer KA; Lemij HG; George RJ; Pel JJM
Graefes Arch Clin Exp Ophthalmol; 2018 Feb; 256(2):371-379. PubMed ID: 29282563
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of oculokinetic perimetry.
Chia WL; Goldberg I; Bauman A
Aust N Z J Ophthalmol; 1999 Oct; 27(5):306-11. PubMed ID: 10571390
[TBL] [Abstract][Full Text] [Related]
11. The detection of glaucomatous visual field defects by oculo-kinetic perimetry: which points are best for screening?
Damato BE; Ahmed J; Allan D; McClure E; Jay JL
Eye (Lond); 1989; 3 ( Pt 6)():727-31. PubMed ID: 2630353
[TBL] [Abstract][Full Text] [Related]
12. Comparison of the oculokinetic perimetry glaucoma screener with two types of visual field analyser.
Greve M; Chisholm IA
Can J Ophthalmol; 1993 Aug; 28(5):201-6. PubMed ID: 8221366
[TBL] [Abstract][Full Text] [Related]
13. Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.
Pineles SL; Volpe NJ; Miller-Ellis E; Galetta SL; Sankar PS; Shindler KS; Maguire MG
Arch Ophthalmol; 2006 Mar; 124(3):363-9. PubMed ID: 16534056
[TBL] [Abstract][Full Text] [Related]
14. Oculokinetic perimetry for the assessment of visual fields.
Clark BJ; Timms C; Franks WA
Arch Dis Child; 1990 Apr; 65(4):432-4. PubMed ID: 2346336
[TBL] [Abstract][Full Text] [Related]
15. A hand-held OKP chart for the screening of glaucoma: preliminary evaluation.
Damato BE; Chyla J; McClure E; Jay JL; Allan D
Eye (Lond); 1990; 4 ( Pt 4)():632-7. PubMed ID: 2226995
[TBL] [Abstract][Full Text] [Related]
16. Is oculokinetic perimetry useful?
Abreu Reyes JA; Gonzalez de la Rosa M; Sanchez Mendez M; Mesa Moreno CG; Santos Barrera R
Int Ophthalmol; 1992 Sep; 16(4-5):215-9. PubMed ID: 1428546
[TBL] [Abstract][Full Text] [Related]
17. Eye movement perimetry in glaucoma.
Trope GE; Eizenman M; Coyle E
Can J Ophthalmol; 1989 Aug; 24(5):197-9. PubMed ID: 2766083
[TBL] [Abstract][Full Text] [Related]
18. Oculokinetic perimetry compared with standard perimetric threshold testing.
Felius J; Langerhorst CT; van den Berg TJ; Greve EL
Int Ophthalmol; 1992 Sep; 16(4-5):221-6. PubMed ID: 1428547
[TBL] [Abstract][Full Text] [Related]
19. Peripheral visual field testing by automated kinetic perimetry in glaucoma.
Stewart WC; Shields MB; Ollie AR
Arch Ophthalmol; 1988 Feb; 106(2):202-6. PubMed ID: 3341975
[TBL] [Abstract][Full Text] [Related]
20. Reclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.
Mönter VM; Crabb DP; Artes PH
Invest Ophthalmol Vis Sci; 2017 Feb; 58(2):868-875. PubMed ID: 28159974
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]