These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 33780622)

  • 1. Overestimation of 3α- over 3β
    Schorr P; Kovačević B; Volmer DA
    J Am Soc Mass Spectrom; 2021 Apr; 32(4):1116-1125. PubMed ID: 33780622
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification of the 3α and 3β epimers of 25-hydroxyvitamin D
    Müller MJ; Stokes CS; Volmer DA
    Talanta; 2017 Apr; 165():398-404. PubMed ID: 28153274
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved quantitative LC-MS/MS analysis of vitamin D metabolites in serum after one-pot double derivatization.
    Schorr P; Stokes CS; Volmer DA
    J Pharm Biomed Anal; 2023 Sep; 234():115522. PubMed ID: 37329649
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing derivatization reagents for quantitative LC-MS/MS analysis of a variety of vitamin D metabolites.
    Alexandridou A; Schorr P; Volmer DA
    Anal Bioanal Chem; 2023 Aug; 415(19):4689-4701. PubMed ID: 37219579
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum.
    van den Ouweland JM; Beijers AM; van Daal H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():195-202. PubMed ID: 25125396
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Misleading measures in Vitamin D analysis: a novel LC-MS/MS assay to account for epimers and isobars.
    Shah I; James R; Barker J; Petroczi A; Naughton DP
    Nutr J; 2011 May; 10():46. PubMed ID: 21569549
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two-dimensional liquid chromatography coupled to tandem mass spectrometry for vitamin D metabolite profiling including the C3-epimer-25-monohydroxyvitamin D3.
    Mena-Bravo A; Priego-Capote F; Luque de Castro MD
    J Chromatogr A; 2016 Jun; 1451():50-57. PubMed ID: 27180887
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.
    Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F
    Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel Cookson-type reagent for enhancing sensitivity and specificity in assessment of infant vitamin D status using liquid chromatography/tandem mass spectrometry.
    Ogawa S; Ooki S; Morohashi M; Yamagata K; Higashi T
    Rapid Commun Mass Spectrom; 2013 Nov; 27(21):2453-60. PubMed ID: 24097402
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Enhancing analysis throughput, sensitivity and specificity in LC/ESI-MS/MS assay of plasma 25-hydroxyvitamin D
    Ogawa S; Kittaka H; Nakata A; Komatsu K; Sugiura T; Satoh M; Nomura F; Higashi T
    J Pharm Biomed Anal; 2017 Mar; 136():126-133. PubMed ID: 28081498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3.
    Netzel BC; Cradic KW; Bro ET; Girtman AB; Cyr RC; Singh RJ; Grebe SK
    Clin Chem; 2011 Mar; 57(3):431-40. PubMed ID: 21245371
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
    Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
    Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.
    Tai SS; Bedner M; Phinney KW
    Anal Chem; 2010 Mar; 82(5):1942-8. PubMed ID: 20136128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The C-3 epimer of 25-hydroxyvitamin D(3) is present in adult serum.
    Lensmeyer G; Poquette M; Wiebe D; Binkley N
    J Clin Endocrinol Metab; 2012 Jan; 97(1):163-8. PubMed ID: 22013102
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 2-fluoro-1-methylpyridinium p-toluene sulfonate: a new LC-MS/MS derivatization reagent for vitamin D metabolites.
    Alexandridou A; Volmer DA
    J Lipid Res; 2023 Aug; 64(8):100409. PubMed ID: 37406930
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Measurement of 25-hydroxyvitamin D3 in human serum by liquid chromatography-tandem mass spectrometry and the control for analytical conditions].
    Zheng X; Ma A; Zhang H; Wang Z; Wang Q; Liang H
    Wei Sheng Yan Jiu; 2012 May; 41(3):485-8, 492. PubMed ID: 23050454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development and validation of a method for determination of plasma 25-hydroxyvitamin D3 3-sulfate using liquid chromatography/tandem mass spectrometry.
    Higashi T; Goto A; Morohashi M; Ogawa S; Komatsu K; Sugiura T; Fukuoka T; Mitamura K
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Oct; 969():230-4. PubMed ID: 25195024
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative evaluation of new Cookson-type reagents for LC/ESI-MS/MS assay of 25-hydroxyvitamin D3 in neonatal blood samples.
    Ogawa S; Kittaka H; Shinoda K; Ooki S; Nakata A; Higashi T
    Biomed Chromatogr; 2016 Jun; 30(6):938-45. PubMed ID: 26451531
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2 μm particle columns: a comparative study.
    Bogusz MJ; Al Enazi E; Tahtamoni M; Jawaad JA; Al Tufail M
    Clin Biochem; 2011 Nov; 44(16):1329-37. PubMed ID: 21907190
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigating Differences in Gas-Phase Conformations of 25-Hydroxyvitamin D3 Sodiated Epimers using Ion Mobility-Mass Spectrometry and Theoretical Modeling.
    Chouinard CD; Cruzeiro VWD; Beekman CR; Roitberg AE; Yost RA
    J Am Soc Mass Spectrom; 2017 Aug; 28(8):1497-1505. PubMed ID: 28417307
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.