169 related articles for article (PubMed ID: 33798053)
21. Underexpansion and ad hoc post-dilation in selected patients undergoing balloon-expandable transcatheter aortic valve replacement.
Barbanti M; Leipsic J; Binder R; Dvir D; Tan J; Freeman M; Norgaard B; Hansson N; Cheung A; Ye J; Yang TH; Maryniak K; Raju R; Thompson A; Blanke P; Lauck S; Wood D; Webb J
J Am Coll Cardiol; 2014 Mar; 63(10):976-81. PubMed ID: 24211502
[TBL] [Abstract][Full Text] [Related]
22. Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series.
Huber C; Praz F; O'Sullivan CJ; Langhammer B; Gloekler S; Stortecky S; von Allmen RS; Meier B; Carrel T; Englberger L; Windecker S; Wenaweser P
Interact Cardiovasc Thorac Surg; 2015 Jun; 20(6):694-700. PubMed ID: 25776924
[TBL] [Abstract][Full Text] [Related]
23. Acute aortic regurgitation underestimated by transesophageal echocardiography after preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for severe aortic stenosis.
Tsujimoto S; Fujii K; Nakai E; Tanaka M; Suwa Y; Shiojima I
Cardiovasc Interv Ther; 2021 Jul; 36(3):395-397. PubMed ID: 33792843
[No Abstract] [Full Text] [Related]
24. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
[TBL] [Abstract][Full Text] [Related]
25. Assessment of Post-Procedural Aortic Regurgitation After TAVR: An Intraprocedural TEE Study.
Mihara H; Shibayama K; Jilaihawi H; Itabashi Y; Berdejo J; Utsunomiya H; Siegel RJ; Makkar RR; Shiota T
JACC Cardiovasc Imaging; 2015 Sep; 8(9):993-1003. PubMed ID: 26319501
[TBL] [Abstract][Full Text] [Related]
26. First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve.
Binder RK; Wood D; Webb JG; Cheung A
Catheter Cardiovasc Interv; 2013 Dec; 82(7):E929-31. PubMed ID: 22821872
[TBL] [Abstract][Full Text] [Related]
27. Aborted sternotomy due to unexpected porcelain aorta: does transcatheter aortic valve replacement offer an alternative choice?
Idrees J; Roselli EE; Raza S; Krishnaswamy A; Mick S; Kapadia S; Pettersson GB; Tuzcu M; Svensson LG
J Thorac Cardiovasc Surg; 2015 Jan; 149(1):131-4. PubMed ID: 25439780
[TBL] [Abstract][Full Text] [Related]
28. Feasibility and safety of transfemoral implantation of Edwards SAPIEN XT prosthesis without balloon valvuloplasty in severe stenosis of native aortic valve.
García E; Martín P; Hernández R; Rodríguez V; Fernández A; Gama V; Almería C; Macaya C
Catheter Cardiovasc Interv; 2014 Apr; 83(5):791-5. PubMed ID: 24285561
[TBL] [Abstract][Full Text] [Related]
29. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
[TBL] [Abstract][Full Text] [Related]
30. Transcatheter Mitral Valve Implantation in a Patient With an Aortic Mechanical Valve.
van Gils L; Rodriguez Olivares R; Ren B; Geleijnse ML; Kappetein AP; De Jaegere PPT; Van Mieghem NM
JACC Cardiovasc Interv; 2016 Feb; 9(4):e31-e33. PubMed ID: 26892092
[No Abstract] [Full Text] [Related]
31. Use of Impella 5.0 Prior to Transcatheter Aortic Valve Replacement in a Patient with Severe Aortic Stenosis and Cardiogenic Shock.
Johnson DW; ErwinIII JP
J Heart Valve Dis; 2017 Jul; 26(4):485-487. PubMed ID: 29302950
[TBL] [Abstract][Full Text] [Related]
32. Transaortic transcatheter aortic valve implantation using the Lotus valve: first-in-man experience.
Bapat V; Asrress KN; Boix R; Lim ZY; Hancock J; Redwood SR
EuroIntervention; 2016 Jun; 12(3):389-93. PubMed ID: 26549373
[TBL] [Abstract][Full Text] [Related]
33. Standardized methodology for transfemoral transcatheter aortic valve replacement with the Edwards Sapien XT valve under fluoroscopy guidance.
Kasel AM; Shivaraju A; Schneider S; Krapf S; Oertel F; Burgdorf C; Ott I; Sumer C; Kastrati A; von Scheidt W; Thilo C
J Invasive Cardiol; 2014 Sep; 26(9):451-61. PubMed ID: 25198489
[TBL] [Abstract][Full Text] [Related]
34. Clinical outcome and paravalvular leakage of the new balloon-expandable Edwards Sapien 3 valve in comparison to its predecessor model (Edwards Sapien XT) in patients undergoing transfemoral aortic valve replacement.
Bocksch W; Grossmann B; Geisler T; Steeg M; Droppa M; Jorbenadze R; Haap M; Gawaz M; Fateh-Moghadam S
Catheter Cardiovasc Interv; 2016 Sep; 88(3):466-75. PubMed ID: 27184353
[TBL] [Abstract][Full Text] [Related]
35. Transcatheter Aortic Valve-in-Valve Replacement Instead of a 4th Sternotomy in a 21-Year-Old Woman with Aortic Homograft Failure.
Díez JG; Schechter M; Dougherty KG; Preventza O; Coselli JS
Tex Heart Inst J; 2016 Aug; 43(4):334-7. PubMed ID: 27547146
[TBL] [Abstract][Full Text] [Related]
36. Bioprosthesis leaflet thrombosis following self-expanding valve-in-valve transcatheter aortic valve replacement in patient taking factor Xa inhibitor and warfarin: A case report.
Buchanan KD; Alraies MC; Weissman G; Ben-Dor I; Satler LF; Waksman R
Cardiovasc Revasc Med; 2018 Jan; 19(1 Pt A):29-32. PubMed ID: 29066342
[TBL] [Abstract][Full Text] [Related]
37. Emergency valve-in-valve transcatheter aortic valve replacement in a patient with degenerated bioprosthetic aortic stenosis and cardiogenic shock on veno-arterial extracorporeal membrane oxygenation.
Summers MR; Mick S; Kapadia SR; Krishnaswamy A
Catheter Cardiovasc Interv; 2018 Sep; 92(3):592-596. PubMed ID: 28296034
[TBL] [Abstract][Full Text] [Related]
38. Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement.
Sinning JM; Vasa-Nicotera M; Chin D; Hammerstingl C; Ghanem A; Bence J; Kovac J; Grube E; Nickenig G; Werner N
J Am Coll Cardiol; 2013 Jul; 62(1):11-20. PubMed ID: 23644081
[TBL] [Abstract][Full Text] [Related]
39. Successful transapical implantation of an Edwards Sapien valve within an insufficient aortic CoreValve prosthesis: an initial experience.
Schleger S; Kasel M; Vogel J; Lieber M; Antoni D; Hoffmann E; Eichinger WB
Ann Thorac Surg; 2013 Mar; 95(3):1070-2. PubMed ID: 23438533
[TBL] [Abstract][Full Text] [Related]
40. Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (placement of aortic transcatheter valve).
Hahn RT; Pibarot P; Webb J; Rodes-Cabau J; Herrmann HC; Williams M; Makkar R; Szeto WY; Main ML; Thourani VH; Tuzcu EM; Kapadia S; Akin J; McAndrew T; Xu K; Leon MB; Kodali SK
JACC Cardiovasc Interv; 2014 Jul; 7(7):781-9. PubMed ID: 25060022
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]