These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 33805752)

  • 1. Graphene Coating Obtained in a Cold-Wall CVD Process on the Co-Cr Alloy (L-605) for Medical Applications.
    Wasyluk Ł; Boiko V; Markowska M; Hasiak M; Saladino ML; Hreniak D; Amati M; Gregoratti L; Zeller P; Biały D; Arkowski J; Wawrzyńska M
    Int J Mol Sci; 2021 Mar; 22(6):. PubMed ID: 33805752
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of metal ion release and corrosion resistance of ZrO2 thin coatings on the dental Co-Cr alloys.
    Hsu HC; Yen SK
    Dent Mater; 1998 Sep; 14(5):339-46. PubMed ID: 10379264
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fabrication of chitosan/heparinized graphene oxide multilayer coating to improve corrosion resistance and biocompatibility of magnesium alloys.
    Gao F; Hu Y; Gong Z; Liu T; Gong T; Liu S; Zhang C; Quan L; Kaveendran B; Pan C
    Mater Sci Eng C Mater Biol Appl; 2019 Nov; 104():109947. PubMed ID: 31499970
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of interfacial layer wettability and thickness on the coating morphology and sirolimus release for drug-eluting stent.
    Bedair TM; Yu SJ; Im SG; Park BJ; Joung YK; Han DK
    J Colloid Interface Sci; 2015 Dec; 460():189-99. PubMed ID: 26319336
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anticoagulation and endothelial cell behaviors of heparin-loaded graphene oxide coating on titanium surface.
    Pan CJ; Pang LQ; Gao F; Wang YN; Liu T; Ye W; Hou YH
    Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():333-40. PubMed ID: 27040227
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Biocompatibility of silicon containing micro-arc oxidation coated magnesium alloy ZK60 with osteoblasts cultured in vitro].
    Yang X; Yin Q; Zhang Y; Li M; Lan G; Lin X; Tan L; Yang K
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 May; 27(5):612-8. PubMed ID: 23879103
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corrosive and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy.
    Ristic L; Vucevic D; Radovic L; Djordjevic S; Nikacevic M; Colic M
    J Prosthodont; 2014 Apr; 23(3):221-6. PubMed ID: 24118161
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of a Novel CVD TiN Coating on a Biomedical Co-Cr Alloy: An Evaluation of Coating Layer and Substrate Characteristics.
    Song SH; Min BK; Hong MH; Kwon TY
    Materials (Basel); 2020 Mar; 13(5):. PubMed ID: 32150803
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Functionalized graphene oxide coating on Ti6Al4V alloy for improved biocompatibility and corrosion resistance.
    Asgar H; Deen KM; Rahman ZU; Shah UH; Raza MA; Haider W
    Mater Sci Eng C Mater Biol Appl; 2019 Jan; 94():920-928. PubMed ID: 30423780
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polyvinyl Alcohol/Graphene Oxide Interlayer for Enhancing Adhesive Performance of HA Coating on C/C Composites Prepared by Hydrothermal Electrodeposition/Hydrothermal Treatment.
    Xiong XB; Liu C; Ni XY; Liang CQ; Zeng XR
    ACS Appl Mater Interfaces; 2020 Dec; 12(50):55710-55722. PubMed ID: 33263993
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrochemically reduced graphene oxide on CoCr biomedical alloy: Characterization, macrophage biocompatibility and hemocompatibility in rats with graphene and graphene oxide.
    Escudero ML; Llorente I; Pérez-Maceda BT; José-Pinilla SS; Sánchez-López L; Lozano RM; Aguado-Henche S; de Arriba CC; Alobera-Gracia MA; García-Alonso MC
    Mater Sci Eng C Mater Biol Appl; 2020 Apr; 109():110522. PubMed ID: 32228976
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Paclitaxel delivery from cobalt-chromium alloy surfaces using self-assembled monolayers.
    Mani G; Torres N; Oh S
    Biointerphases; 2011 Jun; 6(2):33-42. PubMed ID: 21721838
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the mechanical properties and porcelain bond strength of cobalt-chromium dental alloy fabricated by selective laser melting.
    Wu L; Zhu H; Gai X; Wang Y
    J Prosthet Dent; 2014 Jan; 111(1):51-5. PubMed ID: 24161258
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cobalt-based alloys for orthopaedic applications studied by electrochemical and XPS analysis.
    Kocijan A; Milosev I; Pihlar B
    J Mater Sci Mater Med; 2004 Jun; 15(6):643-50. PubMed ID: 15346730
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrochemical, biodegradation and cytotoxicity of graphene oxide nanoparticles/polythreonine as a novel nano-coating on AZ91E Mg alloy staple in gastrectomy surgery.
    El-Kamel RS; Ghoneim AA; Fekry AM
    Mater Sci Eng C Mater Biol Appl; 2019 Oct; 103():109780. PubMed ID: 31349436
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microrough cobalt-chromium alloy surfaces for paclitaxel delivery: preparation, characterization, and in vitro drug release studies.
    Lancaster S; Kakade S; Mani G
    Langmuir; 2012 Aug; 28(31):11511-26. PubMed ID: 22720656
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enhanced Hemocompatibility of a Direct Chemical Vapor Deposition-Derived Graphene Film.
    Meng X; Cheng Y; Wang P; Chen K; Chen Z; Liu X; Fu X; Wang K; Liu K; Liu Z; Duan X
    ACS Appl Mater Interfaces; 2021 Feb; 13(4):4835-4843. PubMed ID: 33474941
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Delivery of paclitaxel from cobalt-chromium alloy surfaces without polymeric carriers.
    Mani G; Macias CE; Feldman MD; Marton D; Oh S; Mauli Agrawal C
    Biomaterials; 2010 Jul; 31(20):5372-84. PubMed ID: 20398928
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of heat treatment on metal-ceramic combination of selective-laser-melted cobalt-chromium alloy.
    Yan X; Xu YX; Wu Y; Lin H
    J Prosthet Dent; 2018 Aug; 120(2):319.e1-319.e6. PubMed ID: 30097265
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrochemical corrosion and surface analyses of a ni-cr alloy in bleaching agents.
    Tamam E; Aydın AK; Bilgiç S
    J Prosthodont; 2014 Oct; 23(7):549-58. PubMed ID: 24750374
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.