These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 33807358)

  • 1. Shear Wave Elastography and Shear Wave Dispersion Imaging in the Assessment of Liver Disease in Alpha1-Antitrypsin Deficiency.
    Schulz M; Kleinjans M; Strnad P; Demir M; Holtmann TM; Tacke F; Wree A
    Diagnostics (Basel); 2021 Mar; 11(4):. PubMed ID: 33807358
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shear wave elastography and shear wave dispersion imaging in primary biliary cholangitis-a pilot study.
    Schulz M; Wilde AB; Demir M; Müller T; Tacke F; Wree A
    Quant Imaging Med Surg; 2022 Feb; 12(2):1235-1242. PubMed ID: 35111619
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of non-invasive assessment of liver fibrosis in patients with alpha1-antitrypsin deficiency using magnetic resonance elastography (MRE), acoustic radiation force impulse (ARFI) Quantification, and 2D-shear wave elastography (2D-SWE).
    Reiter R; Wetzel M; Hamesch K; Strnad P; Asbach P; Haas M; Siegmund B; Trautwein C; Hamm B; Klatt D; Braun J; Sack I; Tzschätzsch H
    PLoS One; 2018; 13(4):e0196486. PubMed ID: 29698472
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic performance of two-dimensional shear wave elastography and attenuation imaging for fibrosis and steatosis assessment in chronic liver disease.
    Kobayashi T; Nakatsuka T; Sato M; Soroida Y; Hikita H; Gotoh H; Iwai T; Tateishi R; Kurano M; Fujishiro M
    J Med Ultrason (2001); 2024 Jun; ():. PubMed ID: 38951430
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Different Ultrasound Shear Wave Elastography Techniques as Novel Imaging-Based Approaches for Quantitative Evaluation of Hepatic Steatosis-Preliminary Findings.
    Platz Batista da Silva N; Scharf G; Lürken L; Verloh N; Schleder S; Stroszczynski C; Jung EM; Haimerl M
    Tomography; 2023 Mar; 9(2):681-692. PubMed ID: 36961013
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reduction of Shear Wave Elastography but Not Shear Wave Dispersion After Successful Hepatitis C Treatment With Direct-Acting Antiviral Agents.
    Su PY; Su WW; Wu LS; Hsu PK; Huang SP; Hsu YC
    J Ultrasound Med; 2021 Sep; 40(9):1919-1926. PubMed ID: 33400288
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantification of Steatosis and Fibrosis using a new system implemented in an ultrasound machine.
    Sporea I; Bâldea V; Lupușoru R; Bende F; Mare R; Lazăr A; Popescu A; Șirli R
    Med Ultrason; 2020 Sep; 22(3):265-271. PubMed ID: 32399537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnostic Performance of 2-D Shear-Wave Elastography with Propagation Maps and Attenuation Imaging in Patients with Non-Alcoholic Fatty Liver Disease.
    Podrug K; Sporea I; Lupusoru R; Pastrovic F; Mustapic S; Bâldea V; Bozin T; Bokun T; Salkic N; Șirli R; Popescu A; Puljiz Z; Grgurevic I
    Ultrasound Med Biol; 2021 Aug; 47(8):2128-2137. PubMed ID: 33985827
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Shear wave elastography and shear wave dispersion correlated to biopsy at the scheduled follow-up of pediatric liver grafts.
    Cetinic I; de Lange C; Boström H; Ekvall N; Bennet W; Lagerstrand K; Hebelka H
    Pediatr Transplant; 2023 Nov; 27(7):e14591. PubMed ID: 37583096
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the diagnostic performance of shear wave elastography with shear wave dispersion for pre-operative staging of hepatic fibrosis in patients with hepatocellular carcinoma.
    Wang K; Yu D; Li G; Wen L; Zhang S
    Eur J Radiol; 2022 Sep; 154():110459. PubMed ID: 35926355
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical Application of Shear Wave Elastography With Shear Wave Dispersion Imaging in the Preoperative Evaluation of Hepatic Parenchyma in Patients With Liver Tumors.
    Wang K; Zhang S; Zhou W; Wen L; Zhang S; Yu D
    J Ultrasound Med; 2023 Apr; 42(4):797-807. PubMed ID: 35730210
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasound Shear Wave Elastography, Shear Wave Dispersion and Attenuation Imaging of Pediatric Liver Disease with Histological Correlation.
    Cetinic I; de Lange C; Simrén Y; Ekvall N; Östling M; Stén L; Boström H; Lagerstrand K; Hebelka H
    Children (Basel); 2022 May; 9(5):. PubMed ID: 35626865
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
    Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
    Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children.
    Cetiner M; Schiepek F; Finkelberg I; Hirtz R; Büscher AK
    Front Pediatr; 2023; 11():1020690. PubMed ID: 37138563
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Which are the cut-off values of 2D-Shear Wave Elastography (2D-SWE) liver stiffness measurements predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method?
    Sporea I; Bota S; Gradinaru-Taşcău O; Sirli R; Popescu A; Jurchiş A
    Eur J Radiol; 2014 Mar; 83(3):e118-22. PubMed ID: 24380640
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of liver stiffness measurements by a 2D-shear wave technique and transient elastography: results from a European prospective multi-centre study.
    Ronot M; Ferraioli G; Müller HP; Friedrich-Rust M; Filice C; Vilgrain V; Cosgrove D; Lim AK
    Eur Radiol; 2021 Mar; 31(3):1578-1587. PubMed ID: 32902745
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Fibroscan, Shear Wave Elastography, and Shear Wave Dispersion Measurements in Evaluating Fibrosis and Necroinflammation in Patients Who Underwent Liver Biopsy.
    Seyrek S; Ayyildiz H; Bulakci M; Salmaslioglu A; Seyrek F; Gultekin B; Cavus B; Berker N; Buyuk M; Yuce S
    Ultrasound Q; 2024 Mar; 40(1):74-81. PubMed ID: 38345402
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Poor correlation of 2D shear wave elastography and transient elastography in Fontan-associated liver disease: A head-to-head comparison.
    Gill M; Mudaliar S; Prince D; Than NN; Cordina R; Majumdar A
    JGH Open; 2023 Oct; 7(10):690-697. PubMed ID: 37908293
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study between pSWE and 2D-SWE techniques integrated in the same ultrasound machine, with Transient Elastography as the reference method.
    Foncea CG; Popescu A; Lupusoru R; Fofiu R; Sirli R; Danila M; Sporea I
    Med Ultrason; 2020 Mar; 22(1):13-19. PubMed ID: 32096782
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of liver fibrosis in chronic hepatitis: comparison of shear wave elastography and transient elastography.
    Paul SB; Das P; Mahanta M; Sreenivas V; Kedia S; Kalra N; Kaur H; Vijayvargiya M; Ghosh S; Gamanagatti SR; Shalimar ; Gupta SD; Acharya SK
    Abdom Radiol (NY); 2017 Dec; 42(12):2864-2873. PubMed ID: 28643136
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.