These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 33810187)

  • 1. Towards Precise Interpretation of Oil Transformers via Novel Combined Techniques Based on DGA and Partial Discharge Sensors.
    Ward SA; El-Faraskoury A; Badawi M; Ibrahim SA; Mahmoud K; Lehtonen M; Darwish MMF
    Sensors (Basel); 2021 Mar; 21(6):. PubMed ID: 33810187
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dissolved Gas Analysis Equipment for Online Monitoring of Transformer Oil: A Review.
    Bustamante S; Manana M; Arroyo A; Castro P; Laso A; Martinez R
    Sensors (Basel); 2019 Sep; 19(19):. PubMed ID: 31546981
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Localization for Dual Partial Discharge Sources in Transformer Oil Using Pressure-Balanced Fiber-Optic Ultrasonic Sensor Array.
    Liu F; Shi Y; Zhang S; Wang W
    Sensors (Basel); 2024 Jul; 24(14):. PubMed ID: 39065847
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors.
    Castro B; Clerice G; Ramos C; Andreoli A; Baptista F; Campos F; Ulson J
    Sensors (Basel); 2016 Aug; 16(8):. PubMed ID: 27517931
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fuzzy reinforcement learning based intelligent classifier for power transformer faults.
    Malik H; Sharma R; Mishra S
    ISA Trans; 2020 Jun; 101():390-398. PubMed ID: 31959374
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a spectrofluorimetry-based device for determining the acetylene content in the oils of power transformers.
    Quintella CM; Meira M; Silva WL; Filho RG; Araújo AL; Júnior ET; Sales LJ
    Talanta; 2013 Dec; 117():263-7. PubMed ID: 24209339
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel approach for oil-based transformer fault identification in electrical secondary distribution networks.
    Mbembati H; Bakiri H
    Heliyon; 2024 Mar; 10(5):e26336. PubMed ID: 38434289
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Fault Diagnosis Method for a Power Transformer Based on Multi-Scale Approximate Entropy and Optimized Convolutional Networks.
    Shang H; Liu Z; Wei Y; Zhang S
    Entropy (Basel); 2024 Feb; 26(3):. PubMed ID: 38539698
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel Probabilistic Neural Network Models Combined with Dissolved Gas Analysis for Fault Diagnosis of Oil-Immersed Power Transformers.
    Zhou Y; Tao L; Yang X; Yang L
    ACS Omega; 2021 Jul; 6(28):18084-18098. PubMed ID: 34308042
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Machine learning based multi-method interpretation to enhance dissolved gas analysis for power transformer fault diagnosis.
    Suwarno ; Sutikno H; Prasojo RA; Abu-Siada A
    Heliyon; 2024 Feb; 10(4):e25975. PubMed ID: 38379965
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neural networks and particle swarm for transformer oil diagnosis by dissolved gas analysis.
    Guerbas F; Benmahamed Y; Teguar Y; Dahmani RA; Teguar M; Ali E; Bajaj M; Dost Mohammadi SA; Ghoneim SSM
    Sci Rep; 2024 Apr; 14(1):9271. PubMed ID: 38649709
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of WO
    Wei Z; Xu L; Peng S; Zhou Q
    Front Chem; 2020; 8():188. PubMed ID: 32318538
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of back propagation neural network in complex diagnostics and forecasting loss of life of cellulose paper insulation in oil-immersed transformers.
    Ngwenyama MK; Gitau MN
    Sci Rep; 2024 Mar; 14(1):6080. PubMed ID: 38480776
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transformer Incipient Fault Prediction Using Combined Artificial Neural Network and Various Particle Swarm Optimisation Techniques.
    Illias HA; Chai XR; Abu Bakar AH; Mokhlis H
    PLoS One; 2015; 10(6):e0129363. PubMed ID: 26103634
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical Fiber Sensors for Structural Monitoring in Power Transformers.
    Monteiro CS; Rodrigues AV; Viveiros D; Linhares C; Mendes H; Silva SO; Marques PVS; Tavares SMO; Frazão O
    Sensors (Basel); 2021 Sep; 21(18):. PubMed ID: 34577333
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Novel Fault Diagnosis System on Polymer Insulation of Power Transformers Based on 3-stage GA⁻SA⁻SVM OFC Selection and ABC⁻SVM Classifier.
    Huang X; Zhang Y; Liu J; Zheng H; Wang K
    Polymers (Basel); 2018 Oct; 10(10):. PubMed ID: 30961021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tracing Acetylene Dissolved in Transformer Oil by Tunable Diode Laser Absorption Spectrum.
    Ma GM; Zhao SJ; Jiang J; Song HT; Li CR; Luo YT; Wu H
    Sci Rep; 2017 Nov; 7(1):14961. PubMed ID: 29097719
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Acoustic Sensors for Monitoring and Localizing Partial Discharge Signals in Oil-Immersed Transformers under Array Configuration.
    Wang Y; Zhao D; Jia Y; Wang S; Du Y; Li H; Zhang B
    Sensors (Basel); 2024 Jul; 24(14):. PubMed ID: 39066101
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Discernment of transformer oil stray gassing anomalies using machine learning classification techniques.
    Ngwenyama MK; Gitau MN
    Sci Rep; 2024 Jan; 14(1):376. PubMed ID: 38172563
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accurate Assessment of Moisture Content and Degree of Polymerization in Power Transformers via Dielectric Response Sensing.
    Kunakorn A; Pramualsingha S; Yutthagowith P; Nimsanong P; Kittiratsatcha S
    Sensors (Basel); 2023 Oct; 23(19):. PubMed ID: 37837066
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.