BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 33812576)

  • 1. Double layer composite membrane for preventing tendon adhesion and promoting tendon healing.
    Yan Z; Meng X; Su Y; Chen Y; Zhang L; Xiao J
    Mater Sci Eng C Mater Biol Appl; 2021 Apr; 123():111941. PubMed ID: 33812576
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tendon healing and anti-adhesion properties of electrospun fibrous membranes containing bFGF loaded nanoparticles.
    Liu S; Qin M; Hu C; Wu F; Cui W; Jin T; Fan C
    Biomaterials; 2013 Jun; 34(19):4690-701. PubMed ID: 23541108
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Experimental study on basic fibroblast growth factor combined slow-releasing degradable membrane to prevent tendon adhesion].
    Sha DF; Xin CT; Yang XX
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2004 Mar; 18(2):148-51. PubMed ID: 15065419
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Uni-directional release of ibuprofen from an asymmetric fibrous membrane enables effective peritendinous anti-adhesion.
    Deng J; Yao Z; Wang S; Zhang X; Zhan L; Wang T; Yu W; Zeng J; Wu J; Fu S; Wu S; Ouyang Y; Huang C
    J Control Release; 2024 Jun; 372():251-264. PubMed ID: 38908755
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Multi-functional electrospun antibacterial core-shell nanofibrous membranes for prolonged prevention of post-surgical tendon adhesion and inflammation.
    Shalumon KT; Sheu C; Chen CH; Chen SH; Jose G; Kuo CY; Chen JP
    Acta Biomater; 2018 May; 72():121-136. PubMed ID: 29626695
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ibuprofen-Loaded Hyaluronic Acid Nanofibrous Membranes for Prevention of Postoperative Tendon Adhesion through Reduction of Inflammation.
    Chen CT; Chen CH; Sheu C; Chen JP
    Int J Mol Sci; 2019 Oct; 20(20):. PubMed ID: 31614502
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Instantaneous self-healing and strongly adhesive self-adaptive hyaluronic acid-based hydrogel for controlled drug release to promote tendon wound healing.
    Ren Z; Duan Z; Zhang Z; Fu R; Zhu C; Fan D
    Int J Biol Macromol; 2023 Jul; 242(Pt 2):125001. PubMed ID: 37224906
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Release of celecoxib from a bi-layer biomimetic tendon sheath to prevent tissue adhesion.
    Li L; Zheng X; Fan D; Yu S; Wu D; Fan C; Cui W; Ruan H
    Mater Sci Eng C Mater Biol Appl; 2016 Apr; 61():220-6. PubMed ID: 26838844
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sustained co-delivery of ibuprofen and basic fibroblast growth factor by thermosensitive nanoparticle hydrogel as early local treatment of peri-implantitis.
    Chen W; Zhi M; Feng Z; Gao P; Yuan Y; Zhang C; Wang Y; Dong A
    Int J Nanomedicine; 2019; 14():1347-1358. PubMed ID: 30863065
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term drug release from electrospun fibers for in vivo inflammation prevention in the prevention of peritendinous adhesions.
    Hu C; Liu S; Zhang Y; Li B; Yang H; Fan C; Cui W
    Acta Biomater; 2013 Jul; 9(7):7381-8. PubMed ID: 23567943
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prevention of peritendinous adhesions with electrospun poly (lactic acid-co-glycolic acid) (PLGA) bioabsorbable nanofiber: An experimental study.
    Uyanik O; Pekkoc-Uyanik KC; Findik S; Avci A; Altuntas Z
    Colloids Surf B Biointerfaces; 2022 Jan; 209(Pt 2):112181. PubMed ID: 34742023
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Controlled release of bFGF loaded into electrospun core-shell fibrous membranes for use in guided tissue regeneration.
    Zhang H; Wang K; Gao T; Zhang R; Cai Z; Liu J; Ma H; Zhang W
    Biomed Mater; 2020 Apr; 15(3):035021. PubMed ID: 32092709
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Regulation of ERK1/2 and SMAD2/3 Pathways by Using Multi-Layered Electrospun PCL-Amnion Nanofibrous Membranes for the Prevention of Post-Surgical Tendon Adhesion.
    Liu C; Tian S; Bai J; Yu K; Liu L; Liu G; Dong R; Tian D
    Int J Nanomedicine; 2020; 15():927-942. PubMed ID: 32103947
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimization of intrinsic and extrinsic tendon healing through controllable water-soluble mitomycin-C release from electrospun fibers by mediating adhesion-related gene expression.
    Zhao X; Jiang S; Liu S; Chen S; Lin ZY; Pan G; He F; Li F; Fan C; Cui W
    Biomaterials; 2015 Aug; 61():61-74. PubMed ID: 25996412
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Effect of local basic fibroblast growth factor and 5-fluorouracil on accelerating healing and preventing tendon adhesion after flexor tendon repair].
    Sheng J; Zeng B; Jiang P; Fan C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jun; 25(6):711-7. PubMed ID: 21735786
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The efficacy of basic fibroblast growth factor-loaded poly(lactic-co-glycolic acid) nanosheet for mouse wound healing.
    Aoki S; Fujii M; Fujie T; Nishiwaki K; Miyazaki H; Saitoh D; Takeoka S; Kiyosawa T; Kinoshita M
    Wound Repair Regen; 2017 Nov; 25(6):1008-1016. PubMed ID: 29315978
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduction of Peritendinous adhesions by hydrogel containing biocompatible phospholipid polymer MPC for tendon repair.
    Ishiyama N; Moro T; Ohe T; Miura T; Ishihara K; Konno T; Ohyama T; Kimura M; Kyomoto M; Saito T; Nakamura K; Kawaguchi H
    J Bone Joint Surg Am; 2011 Jan; 93(2):142-9. PubMed ID: 21248211
    [TBL] [Abstract][Full Text] [Related]  

  • 18. bFGF- and CaPP-Loaded Fibrin Clots Enhance the Bioactivity of the Tendon-Bone Interface to Augment Healing.
    Zhang C; Li Q; Deng S; Fu W; Tang X; Chen G; Qin T; Li J
    Am J Sports Med; 2016 Aug; 44(8):1972-82. PubMed ID: 27159301
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ibuprofen-Loaded Electrospun PCL/PEG Nanofibrous Membranes for Preventing Postoperative Abdominal Adhesion.
    Kheilnezhad B; Hadjizadeh A
    ACS Appl Bio Mater; 2022 Apr; 5(4):1766-1778. PubMed ID: 35389215
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multi-layer electrospun membrane mimicking tendon sheath for prevention of tendon adhesions.
    Jiang S; Yan H; Fan D; Song J; Fan C
    Int J Mol Sci; 2015 Mar; 16(4):6932-44. PubMed ID: 25822877
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.