BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 33812627)

  • 1. Regulation of endothelial functionality through direct and immunomodulatory effects by Ni-Ti-O nanospindles on NiTi alloy.
    Zhao Y; Wang Z; Bai L; Zhao F; Liu S; Liu Y; Yao X; Hang R
    Mater Sci Eng C Mater Biol Appl; 2021 Apr; 123():112007. PubMed ID: 33812627
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Length-dependent corrosion behavior, Ni
    Hang R; Liu Y; Bai L; Zhang X; Huang X; Jia H; Tang B
    Mater Sci Eng C Mater Biol Appl; 2018 Aug; 89():1-7. PubMed ID: 29752078
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of vascular stent alloys on expression of cellular adhesion molecules by endothelial cells.
    Messer RL; Wataha JC; Lewis JB; Lockwood PE; Caughman GB; Tseng WY
    J Long Term Eff Med Implants; 2005; 15(1):39-47. PubMed ID: 15715515
    [TBL] [Abstract][Full Text] [Related]  

  • 4. (Ti, O)/Ti and (Ti, O, N)/Ti composite coatings fabricated via PIIID for the medical application of NiTi shape memory alloy.
    Sun T; Wang LP; Wang M
    J Biomed Mater Res B Appl Biomater; 2011 Feb; 96(2):249-60. PubMed ID: 21210504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The molecular mechanism for effects of TiN coating on NiTi alloy on endothelial cell function.
    Yang D; Lü X; Hong Y; Xi T; Zhang D
    Biomaterials; 2014 Aug; 35(24):6195-205. PubMed ID: 24818882
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro.
    Wataha JC; Lockwood PE; Marek M; Ghazi M
    J Biomed Mater Res; 1999 Jun; 45(3):251-7. PubMed ID: 10397983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Behaviour of human endothelial cells on surface modified NiTi alloy.
    Plant SD; Grant DM; Leach L
    Biomaterials; 2005 Sep; 26(26):5359-67. PubMed ID: 15814134
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Density functional theory simulation of titanium migration and reaction with oxygen in the early stages of oxidation of equiatomic NiTi alloy.
    Nolan M; Tofail SA
    Biomaterials; 2010 May; 31(13):3439-48. PubMed ID: 20144474
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improved endothelialization of NiTi alloy by VEGF functionalized nanocoating.
    Shen W; Cai K; Yang Z; Yan Y; Yang W; Liu P
    Colloids Surf B Biointerfaces; 2012 Jun; 94():347-53. PubMed ID: 22387019
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Examining the role of nickel and NiTi nanoparticles promoting inflammation and angiogenesis.
    Srivastava AK; Snapper DM; Zheng J; Yildrim BS; Srivastava S; Wood SC
    J Immunotoxicol; 2022 Dec; 19(1):61-73. PubMed ID: 35901199
    [TBL] [Abstract][Full Text] [Related]  

  • 11. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility.
    Michiardi A; Aparicio C; Planell JA; Gil FJ
    J Biomed Mater Res B Appl Biomater; 2006 May; 77(2):249-56. PubMed ID: 16245290
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of modification of oxide layer on NiTi stent corrosion resistance.
    Trépanier C; Tabrizian M; Yahia LH; Bilodeau L; Piron DL
    J Biomed Mater Res; 1998; 43(4):433-40. PubMed ID: 9855202
    [TBL] [Abstract][Full Text] [Related]  

  • 13. PIIID-formed (Ti, O)/Ti, (Ti, N)/Ti and (Ti, O, N)/Ti coatings on NiTi shape memory alloy for medical applications.
    Sun T; Wang LP; Wang M; Tong HW; Lu WW
    Mater Sci Eng C Mater Biol Appl; 2012 Aug; 32(6):1469-79. PubMed ID: 24364947
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Favorable manipulation of macrophage/endothelial cell functionality and their cross-talk on silicon-doped titania nanotube arrays.
    Bai L; Liu Y; Zhang X; Huang X; Yao X; Hang R; Tang B; Xiao Y
    Nanoscale; 2019 Mar; 11(13):5920-5931. PubMed ID: 30693919
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of Ni ion release on the cells in contact with NiTi alloys.
    Veverkova J; Bartkova D; Weiser A; Dlouhy A; Babula P; Stepka P; Pavkova Goldbergova M
    Environ Sci Pollut Res Int; 2020 Mar; 27(8):7934-7942. PubMed ID: 31893362
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparative study of the cytotoxicity and corrosion resistance of nickel-titanium and titanium-niobium shape memory alloys.
    McMahon RE; Ma J; Verkhoturov SV; Munoz-Pinto D; Karaman I; Rubitschek F; Maier HJ; Hahn MS
    Acta Biomater; 2012 Jul; 8(7):2863-70. PubMed ID: 22465573
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduction in nickel content of the surface oxide layer on Ni-Ti alloy by electrolytic treatment.
    Yoneyama T; Hanawa T
    J Oral Sci; 2020 Dec; 63(1):50-53. PubMed ID: 33177275
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Construction of extracellular microenvironment to improve surface endothelialization of NiTi alloy substrate.
    Liu P; Zhao Y; Yan Y; Hu Y; Yang W; Cai K
    Mater Sci Eng C Mater Biol Appl; 2015 Oct; 55():1-7. PubMed ID: 26117732
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Porous TiO₂ surface formed on nickel-titanium alloy by plasma electrolytic oxidation: a prospective polymer-free reservoir for drug eluting stent applications.
    Huan Z; Fratila-Apachitei LE; Apachitei I; Duszczyk J
    J Biomed Mater Res B Appl Biomater; 2013 Jul; 101(5):700-8. PubMed ID: 23359528
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.