These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 33813503)

  • 1. OCCLUSAL TRAUMA OF IMPLANT-SUPPORTED METAL-CERAMIC CROWN: A CASE REPORT.
    Fastovets OO; Kotelevskyi RA; Huriev YS; Kobyliak SS
    Wiad Lek; 2021; 74(2):371-374. PubMed ID: 33813503
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: patient-specific and implant-specific predictors of ceramic failure.
    Kinsel RP; Lin D
    J Prosthet Dent; 2009 Jun; 101(6):388-94. PubMed ID: 19463666
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of crown-to-implant ratio, retention system, restorative material, and occlusal loading on stress concentrations in single short implants.
    Sotto-Maior BS; Senna PM; da Silva WJ; Rocha EP; Del Bel Cury AA
    Int J Oral Maxillofac Implants; 2012; 27(3):e13-8. PubMed ID: 22616067
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal-ceramic crowns.
    Torrado E; Ercoli C; Al Mardini M; Graser GN; Tallents RH; Cordaro L
    J Prosthet Dent; 2004 Jun; 91(6):532-7. PubMed ID: 15211294
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retrievable metal ceramic implant-supported fixed prostheses with milled titanium frameworks and all-ceramic crowns: retrospective clinical study with up to 10 years of follow-up.
    Maló P; de Araújo Nobre M; Borges J; Almeida R
    J Prosthodont; 2012 Jun; 21(4):256-64. PubMed ID: 22339902
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of incisal veneering porcelain thickness of two metal ceramic crown systems on failure resistance after cyclic loading.
    Geminiani A; Lee H; Feng C; Ercoli C
    J Prosthet Dent; 2010 May; 103(5):275-82. PubMed ID: 20416410
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic single crowns.
    Pjetursson BE; Valente NA; Strasding M; Zwahlen M; Liu S; Sailer I
    Clin Oral Implants Res; 2018 Oct; 29 Suppl 16():199-214. PubMed ID: 30328190
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An esthetic comparison of a metal ceramic crown and cast metal abutment with an all-ceramic crown and zirconia abutment: a clinical report.
    Tan PL; Dunne JT
    J Prosthet Dent; 2004 Mar; 91(3):215-8. PubMed ID: 15060488
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Changes in the outcome of metal-ceramic tooth-supported single crowns and FDPs following the introduction of osseointegrated implant dentistry into a prosthodontic practice.
    Walton TR
    Int J Prosthodont; 2009; 22(3):260-7. PubMed ID: 19548408
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the fracture strengths of metal-ceramic crowns and three ceromer crowns.
    Ku CW; Park SW; Yang HS
    J Prosthet Dent; 2002 Aug; 88(2):170-5. PubMed ID: 12397244
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Group 2 ITI Consensus Report: Prosthodontics and implant dentistry.
    Morton D; Gallucci G; Lin WS; Pjetursson B; Polido W; Roehling S; Sailer I; Aghaloo T; Albera H; Bohner L; Braut V; Buser D; Chen S; Dawson A; Eckert S; Gahlert M; Hamilton A; Jaffin R; Jarry C; Karayazgan B; Laine J; Martin W; Rahman L; Schlegel A; Shiota M; Stilwell C; Vorster C; Zembic A; Zhou W
    Clin Oral Implants Res; 2018 Oct; 29 Suppl 16():215-223. PubMed ID: 30328196
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of the veneer-framework interface on the mechanical behavior of ceramic veneers: a nonlinear finite element analysis.
    Lazari PC; Sotto-Maior BS; Rocha EP; de Villa Camargos G; Del Bel Cury AA
    J Prosthet Dent; 2014 Oct; 112(4):857-63. PubMed ID: 24721502
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.
    Eskitascioglu G; Usumez A; Sevimay M; Soykan E; Unsal E
    J Prosthet Dent; 2004 Feb; 91(2):144-50. PubMed ID: 14970760
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Alternative crown systems. Is the metal-ceramic crown always the restoration of choice?
    Wall JG; Cipra DL
    Dent Clin North Am; 1992 Jul; 36(3):765-82. PubMed ID: 1397433
    [TBL] [Abstract][Full Text] [Related]  

  • 15. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs).
    Sailer I; Makarov NA; Thoma DS; Zwahlen M; Pjetursson BE
    Dent Mater; 2015 Jun; 31(6):603-23. PubMed ID: 25842099
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Veneer fracture in implant-supported metal-ceramic restorations. Part I: Overall success rate and impact of occlusal guidance.
    Linkevicius T; Vladimirovas E; Grybauskas S; Puisys A; Rutkunas V
    Stomatologija; 2008; 10(4):133-9. PubMed ID: 19223713
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retrofitting a tooth-supported crown with an implant and abutment: a clinical report.
    Boff LL; Oderich E; Cardoso AC; Magne P
    J Prosthet Dent; 2010 May; 103(5):262-6. PubMed ID: 20416408
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term follow-up of CeraOne™ single-implant restorations: an 18-year follow-up study based on a prospective patient cohort.
    Bergenblock S; Andersson B; Fürst B; Jemt T
    Clin Implant Dent Relat Res; 2012 Aug; 14(4):471-9. PubMed ID: 20586784
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A 1-year randomised controlled trial comparing zirconia versus metal-ceramic implant supported single-tooth restorations.
    Hosseini M; Worsaae N; Schiodt M; Gotfredsen K
    Eur J Oral Implantol; 2011; 4(4):347-61. PubMed ID: 22282731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. All-ceramic, bi-layered crowns supported by zirconia implants: Three-year results of a prospective multicenter study.
    Spies BC; Balmer M; Jung RE; Sailer I; Vach K; Kohal RJ
    J Dent; 2017 Dec; 67():58-65. PubMed ID: 28939484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.