These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 33820009)

  • 1. A scanning tunneling microscope capable of electron spin resonance and pump-probe spectroscopy at mK temperature and in vector magnetic field.
    van Weerdenburg WMJ; Steinbrecher M; van Mullekom NPE; Gerritsen JW; von Allwörden H; Natterer FD; Khajetoorians AA
    Rev Sci Instrum; 2021 Mar; 92(3):033906. PubMed ID: 33820009
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Upgrade of a low-temperature scanning tunneling microscope for electron-spin resonance.
    Natterer FD; Patthey F; Bilgeri T; Forrester PR; Weiss N; Brune H
    Rev Sci Instrum; 2019 Jan; 90(1):013706. PubMed ID: 30709206
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combining electron spin resonance spectroscopy with scanning tunneling microscopy at high magnetic fields.
    Drost R; Uhl M; Kot P; Siebrecht J; Schmid A; Merkt J; Wünsch S; Siegel M; Kieler O; Kleiner R; Ast CR
    Rev Sci Instrum; 2022 Apr; 93(4):043705. PubMed ID: 35489929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Waveform-sequencing for scanning tunneling microscopy based pump-probe spectroscopy and pulsed-ESR.
    Natterer FD
    MethodsX; 2019; 6():1279-1285. PubMed ID: 31198689
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of a scanning tunneling microscope for variable temperature electron spin resonance.
    Hwang J; Krylov D; Elbertse R; Yoon S; Ahn T; Oh J; Fang L; Jang WJ; Cho FH; Heinrich AJ; Bae Y
    Rev Sci Instrum; 2022 Sep; 93(9):093703. PubMed ID: 36182474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and performance of an ultra-high vacuum spin-polarized scanning tunneling microscope operating at 30 mK and in a vector magnetic field.
    von Allwörden H; Eich A; Knol EJ; Hermenau J; Sonntag A; Gerritsen JW; Wegner D; Khajetoorians AA
    Rev Sci Instrum; 2018 Mar; 89(3):033902. PubMed ID: 29604794
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tuning Single-Atom Electron Spin Resonance in a Vector Magnetic Field.
    Willke P; Singha A; Zhang X; Esat T; Lutz CP; Heinrich AJ; Choi T
    Nano Lett; 2019 Nov; 19(11):8201-8206. PubMed ID: 31661282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Invited review article: A 10 mK scanning probe microscopy facility.
    Song YJ; Otte AF; Shvarts V; Zhao Z; Kuk Y; Blankenship SR; Band A; Hess FM; Stroscio JA
    Rev Sci Instrum; 2010 Dec; 81(12):121101. PubMed ID: 21198007
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The design and the performance of an ultrahigh vacuum
    Guan SY; Liao HS; Juang BJ; Chin SC; Chuang TM; Chang CS
    Ultramicroscopy; 2019 Jan; 196():180-185. PubMed ID: 30423505
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anisotropic Hyperfine Interaction of Surface-Adsorbed Single Atoms.
    Kim J; Noh K; Chen Y; Donati F; Heinrich AJ; Wolf C; Bae Y
    Nano Lett; 2022 Dec; 22(23):9766-9772. PubMed ID: 36317830
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An ultra-high vacuum scanning tunneling microscope operating at sub-Kelvin temperatures and high magnetic fields for spin-resolved measurements.
    Salazar C; Baumann D; Hänke T; Scheffler M; Kühne T; Kaiser M; Voigtländer R; Lindackers D; Büchner B; Hess C
    Rev Sci Instrum; 2018 Jun; 89(6):065104. PubMed ID: 29960518
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Double-Resonance Spectroscopy of Coupled Electron Spins on a Surface.
    Phark SH; Chen Y; Bui HT; Wang Y; Haze M; Kim J; Bae Y; Heinrich AJ; Wolf C
    ACS Nano; 2023 Jul; 17(14):14144-14151. PubMed ID: 37406167
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A modular ultra-high vacuum millikelvin scanning tunneling microscope.
    Wong D; Jeon S; Nuckolls KP; Oh M; Kingsley SCJ; Yazdani A
    Rev Sci Instrum; 2020 Feb; 91(2):023703. PubMed ID: 32113373
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A spectroscopic-imaging scanning tunneling microscope in vector magnetic field.
    Zhou L; He Q; Que X; Rost AW; Takagi H
    Rev Sci Instrum; 2023 Mar; 94(3):033704. PubMed ID: 37012779
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips.
    Roychowdhury A; Gubrud MA; Dana R; Anderson JR; Lobb CJ; Wellstood FC; Dreyer M
    Rev Sci Instrum; 2014 Apr; 85(4):043706. PubMed ID: 24784617
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of the Magnetic Tip on Heterodimers in Electron Spin Resonance Combined with Scanning Tunneling Microscopy.
    Zhang X; Reina-Gálvez J; Wolf C; Wang Y; Aubin H; Heinrich AJ; Choi T
    ACS Nano; 2023 Sep; 17(17):16935-16942. PubMed ID: 37643247
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electric control of spin transitions at the atomic scale.
    Kot P; Ismail M; Drost R; Siebrecht J; Huang H; Ast CR
    Nat Commun; 2023 Oct; 14(1):6612. PubMed ID: 37857623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A 10 mK scanning tunneling microscope operating in ultra high vacuum and high magnetic fields.
    Assig M; Etzkorn M; Enders A; Stiepany W; Ast CR; Kern K
    Rev Sci Instrum; 2013 Mar; 84(3):033903. PubMed ID: 23556826
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A millikelvin scanning tunneling microscope in ultra-high vacuum with adiabatic demagnetization refrigeration.
    Esat T; Borgens P; Yang X; Coenen P; Cherepanov V; Raccanelli A; Tautz FS; Temirov R
    Rev Sci Instrum; 2021 Jun; 92(6):063701. PubMed ID: 34243501
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Amplifier for scanning tunneling microscopy at MHz frequencies.
    Bastiaans KM; Benschop T; Chatzopoulos D; Cho D; Dong Q; Jin Y; Allan MP
    Rev Sci Instrum; 2018 Sep; 89(9):093709. PubMed ID: 30278769
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.