These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 33821351)

  • 1. Vacuum plasma sprayed porous titanium coating on polyetheretherketone for ACDF improves the osteogenic ability: An in vitro and in vivo study.
    Liu C; Zhang Y; Xiao L; Ge X; Öner FC; Xu H
    Biomed Microdevices; 2021 Apr; 23(2):21. PubMed ID: 33821351
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Additive-manufactured Ti-6Al-4 V/Polyetheretherketone composite porous cage for Interbody fusion: bone growth and biocompatibility evaluation in a porcine model.
    Tsai PI; Wu MH; Li YY; Lin TH; Tsai JSC; Huang HI; Lai HJ; Lee MH; Chen CY
    BMC Musculoskelet Disord; 2021 Feb; 22(1):171. PubMed ID: 33573634
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK.
    Torstrick FB; Lin ASP; Potter D; Safranski DL; Sulchek TA; Gall K; Guldberg RE
    Biomaterials; 2018 Dec; 185():106-116. PubMed ID: 30236838
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Superior Osteo-Inductive and Osteo-Conductive Properties of Trabecular Titanium vs. PEEK Scaffolds on Human Mesenchymal Stem Cells: A Proof of Concept for the Use of Fusion Cages.
    Ragni E; Perucca Orfei C; Bidossi A; De Vecchi E; Francaviglia N; Romano A; Maestretti G; Tartara F; de Girolamo L
    Int J Mol Sci; 2021 Feb; 22(5):. PubMed ID: 33673509
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Titanium-interlayer mediated hydroxyapatite coating on polyetheretherketone: a prospective study in patients with single-level cervical degenerative disc disease.
    Zhu C; He M; Mao L; Li T; Zhang L; Liu L; Feng G; Song Y
    J Transl Med; 2021 Jan; 19(1):14. PubMed ID: 33407627
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Porous titanium-coated polyetheretherketone implants exhibit an improved bone-implant interface: an in vitro and in vivo biochemical, biomechanical, and histological study.
    Cheng BC; Koduri S; Wing CA; Woolery N; Cook DJ; Spiro RC
    Med Devices (Auckl); 2018; 11():391-402. PubMed ID: 30464653
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison in the same intervertebral space between titanium-coated and uncoated PEEK cages in lumbar interbody fusion surgery.
    Kashii M; Kitaguchi K; Makino T; Kaito T
    J Orthop Sci; 2020 Jul; 25(4):565-570. PubMed ID: 31375363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Porous titanium-6 aluminum-4 vanadium cage has better osseointegration and less micromotion than a poly-ether-ether-ketone cage in sheep vertebral fusion.
    Wu SH; Li Y; Zhang YQ; Li XK; Yuan CF; Hao YL; Zhang ZY; Guo Z
    Artif Organs; 2013 Dec; 37(12):E191-201. PubMed ID: 24147953
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage.
    Adl Amini D; Okano I; Oezel L; Zhu J; Chiapparelli E; Shue J; Sama AA; Cammisa FP; Girardi FP; Hughes AP
    Eur Spine J; 2021 Aug; 30(8):2377-2384. PubMed ID: 34215921
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties.
    Han CM; Lee EJ; Kim HE; Koh YH; Kim KN; Ha Y; Kuh SU
    Biomaterials; 2010 May; 31(13):3465-70. PubMed ID: 20153890
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Titanium/Polyetheretherketone Cages for Cervical Arthrodesis with Degenerative and Traumatic Pathologies: Early Clinical Outcomes and Fusion Rates.
    Chong E; Mobbs RJ; Pelletier MH; Walsh WR
    Orthop Surg; 2016 Feb; 8(1):19-26. PubMed ID: 27028377
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outcomes of interbody fusion cages used in 1 and 2-levels anterior cervical discectomy and fusion: titanium cages versus polyetheretherketone (PEEK) cages.
    Niu CC; Liao JC; Chen WJ; Chen LH
    J Spinal Disord Tech; 2010 Jul; 23(5):310-6. PubMed ID: 20124907
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Titanium (Ti) cages may be superior to polyetheretherketone (PEEK) cages in lumbar interbody fusion: a systematic review and meta-analysis of clinical and radiological outcomes of spinal interbody fusions using Ti versus PEEK cages.
    Tan JH; Cheong CK; Hey HWD
    Eur Spine J; 2021 May; 30(5):1285-1295. PubMed ID: 33555365
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Titanium vs. polyetheretherketone (PEEK) interbody fusion: Meta-analysis and review of the literature.
    Seaman S; Kerezoudis P; Bydon M; Torner JC; Hitchon PW
    J Clin Neurosci; 2017 Oct; 44():23-29. PubMed ID: 28736113
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Titanium interlayer-mediated hydroxyapatite-coated polyetheretherketone cage in transforaminal lumbar interbody fusion surgery.
    Zhu C; He M; Mao L; Yang H; Hu B; Zhang L; Feng G; Liu L; Song Y
    BMC Musculoskelet Disord; 2021 Nov; 22(1):918. PubMed ID: 34724952
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model.
    McGilvray KC; Easley J; Seim HB; Regan D; Berven SH; Hsu WK; Mroz TE; Puttlitz CM
    Spine J; 2018 Jul; 18(7):1250-1260. PubMed ID: 29496624
    [TBL] [Abstract][Full Text] [Related]  

  • 17. PEEK Versus Ti Interbody Fusion Devices: Resultant Fusion, Bone Apposition, Initial and 26-Week Biomechanics.
    Pelletier MH; Cordaro N; Punjabi VM; Waites M; Lau A; Walsh WR
    Clin Spine Surg; 2016 May; 29(4):E208-14. PubMed ID: 22801456
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The in vivo response to a novel Ti coating compared with polyether ether ketone: evaluation of the periphery and inner surfaces of an implant.
    Walsh WR; Pelletier MH; Christou C; He J; Vizesi F; Boden SD
    Spine J; 2018 Jul; 18(7):1231-1240. PubMed ID: 29496625
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of porous orthopaedic implant material and structure on load sharing with simulated bone ingrowth: A finite element analysis comparing titanium and PEEK.
    Carpenter RD; Klosterhoff BS; Torstrick FB; Foley KT; Burkus JK; Lee CSD; Gall K; Guldberg RE; Safranski DL
    J Mech Behav Biomed Mater; 2018 Apr; 80():68-76. PubMed ID: 29414477
    [TBL] [Abstract][Full Text] [Related]  

  • 20. PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence.
    Campbell PG; Cavanaugh DA; Nunley P; Utter PA; Kerr E; Wadhwa R; Stone M
    Neurosurg Focus; 2020 Sep; 49(3):E10. PubMed ID: 32871573
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.