186 related articles for article (PubMed ID: 33832823)
1. Prostate Cancer Detection Using 3-D Shear Wave Elasticity Imaging.
Morris DC; Chan DY; Palmeri ML; Polascik TJ; Foo WC; Nightingale KR
Ultrasound Med Biol; 2021 Jul; 47(7):1670-1680. PubMed ID: 33832823
[TBL] [Abstract][Full Text] [Related]
2. Characterizing stiffness of human prostates using acoustic radiation force.
Zhai L; Madden J; Foo WC; Mouraviev V; Polascik TJ; Palmeri ML; Nightingale KR
Ultrason Imaging; 2010 Oct; 32(4):201-13. PubMed ID: 21213566
[TBL] [Abstract][Full Text] [Related]
3. Diagnostic Value of Transrectal Shear Wave Elastography for Prostate Cancer Detection in Peripheral Zone: Comparison with Magnetic Resonance Imaging.
Fu S; Tang Y; Tan S; Zhao Y; Cui L
J Endourol; 2020 May; 34(5):558-566. PubMed ID: 32164448
[No Abstract] [Full Text] [Related]
4. Multiparametric Ultrasound for Targeting Prostate Cancer: Combining ARFI, SWEI, QUS and B-Mode.
Morris DC; Chan DY; Lye TH; Chen H; Palmeri ML; Polascik TJ; Foo WC; Huang J; Mamou J; Nightingale KR
Ultrasound Med Biol; 2020 Dec; 46(12):3426-3439. PubMed ID: 32988673
[TBL] [Abstract][Full Text] [Related]
5. Stiffness of prostate gland measured by transrectal real-time shear wave elastography for detection of prostate cancer: a feasibility study.
Ji Y; Ruan L; Ren W; Dun G; Liu J; Zhang Y; Wan Q
Br J Radiol; 2019 May; 92(1097):20180970. PubMed ID: 30875242
[TBL] [Abstract][Full Text] [Related]
6. [Prostate cancer detection by assessing stiffness of different tissues using shear wave ultrasound elastog- raphy].
Glybochko PV; Alyaev YG; Amosov AV; Krupinov GE; Ganzha TM; Vorobev AV; Lumpov IS; Semendyaev RI
Urologiia; 2016 Aug; (3):56-61. PubMed ID: 28247631
[TBL] [Abstract][Full Text] [Related]
7. Automated multiparametric localization of prostate cancer based on B-mode, shear-wave elastography, and contrast-enhanced ultrasound radiomics.
Wildeboer RR; Mannaerts CK; van Sloun RJG; Budäus L; Tilki D; Wijkstra H; Salomon G; Mischi M
Eur Radiol; 2020 Feb; 30(2):806-815. PubMed ID: 31602512
[TBL] [Abstract][Full Text] [Related]
8. Combined ARFI and Shear Wave Imaging of Prostate Cancer: Optimizing Beam Sequences and Parameter Reconstruction Approaches.
Chan DY; Morris DC; Polascik TJ; Palmeri ML; Nightingale KR
Ultrason Imaging; 2023 Jul; 45(4):175-186. PubMed ID: 37129257
[TBL] [Abstract][Full Text] [Related]
9. Correlation of Stiffness of Prostate Cancer Measured by Shear Wave Elastography with Grade Group: A Preliminary Study.
Dai WB; Xu J; Yu B; Chen L; Chen Y; Zhan J
Ultrasound Med Biol; 2021 Feb; 47(2):288-295. PubMed ID: 33234327
[TBL] [Abstract][Full Text] [Related]
10. Multiparametric ultrasound: evaluation of greyscale, shear wave elastography and contrast-enhanced ultrasound for prostate cancer detection and localization in correlation to radical prostatectomy specimens.
Mannaerts CK; Wildeboer RR; Postema AW; Hagemann J; Budäus L; Tilki D; Mischi M; Wijkstra H; Salomon G
BMC Urol; 2018 Nov; 18(1):98. PubMed ID: 30409150
[TBL] [Abstract][Full Text] [Related]
11. Shear wave ultrasound elastography of the prostate: initial results.
Barr RG; Memo R; Schaub CR
Ultrasound Q; 2012 Mar; 28(1):13-20. PubMed ID: 22357224
[TBL] [Abstract][Full Text] [Related]
12. Shear wave elastography for localization of prostate cancer lesions and assessment of elasticity thresholds: implications for targeted biopsies and active surveillance protocols.
Boehm K; Salomon G; Beyer B; Schiffmann J; Simonis K; Graefen M; Budaeus L
J Urol; 2015 Mar; 193(3):794-800. PubMed ID: 25264337
[TBL] [Abstract][Full Text] [Related]
13. Value of Real-Time Shear Wave Elastography Versus Acoustic Radiation Force Impulse Imaging in the Diagnosis of Female Bladder Neck Obstruction.
Qian M; Jiang D; Su C; Wang X; Zhao X; Yang S
J Ultrasound Med; 2019 Sep; 38(9):2427-2435. PubMed ID: 30680774
[TBL] [Abstract][Full Text] [Related]
14. Evaluating the feasibility of acoustic radiation force impulse shear wave elasticity imaging of the uterine cervix with an intracavity array: a simulation study.
Palmeri ML; Feltovich H; Homyk AD; Carlson LC; Hall TJ
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Oct; 60(10):2053-64. PubMed ID: 24081254
[TBL] [Abstract][Full Text] [Related]
15. [Transrectal shear wave elastography combined with transition zone biopsy for detecting prostate cancer].
Zhang M; Wang P; Yin B; Fei X; Xu XW; Song YS
Zhonghua Nan Ke Xue; 2015 Jul; 21(7):610-4. PubMed ID: 26333222
[TBL] [Abstract][Full Text] [Related]
16. Tomoelastography Based on Multifrequency MR Elastography for Prostate Cancer Detection: Comparison with Multiparametric MRI.
Li M; Guo J; Hu P; Jiang H; Chen J; Hu J; Asbach P; Sack I; Li W
Radiology; 2021 May; 299(2):362-370. PubMed ID: 33687285
[TBL] [Abstract][Full Text] [Related]
17. Single- and multiple-track-location shear wave and acoustic radiation force impulse imaging: matched comparison of contrast, contrast-to-noise ratio and resolution.
Hollender PJ; Rosenzweig SJ; Nightingale KR; Trahey GE
Ultrasound Med Biol; 2015 Apr; 41(4):1043-57. PubMed ID: 25701531
[TBL] [Abstract][Full Text] [Related]
18. Repeatability of Rotational 3-D Shear Wave Elasticity Imaging Measurements in Skeletal Muscle.
Paley CT; Knight AE; Jin FQ; Moavenzadeh SR; Pietrosimone LS; Hobson-Webb LD; Rouze NC; Palmeri ML; Nightingale KR
Ultrasound Med Biol; 2023 Mar; 49(3):750-760. PubMed ID: 36543617
[TBL] [Abstract][Full Text] [Related]
19. Shear Wave Elasticity Imaging Using Nondiffractive Bessel Apodized Acoustic Radiation Force.
Feng F; Goswami S; Khan S; McAleavey SA
IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Dec; 68(12):3528-3539. PubMed ID: 34236961
[TBL] [Abstract][Full Text] [Related]
20. Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer.
Ahmad S; Cao R; Varghese T; Bidaut L; Nabi G
Surg Endosc; 2013 Sep; 27(9):3280-7. PubMed ID: 23525883
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]