155 related articles for article (PubMed ID: 33832823)
21. [Shear wave elastography for guiding prostate puncture and differential diagnosis of prostatic lesions].
Wei J; Yang X; Wei C; Zhang YB
Zhonghua Nan Ke Xue; 2019 Sep; 25(9):792-796. PubMed ID: 32233205
[TBL] [Abstract][Full Text] [Related]
22. Prostate cancer: diagnostic performance of real-time shear-wave elastography.
Correas JM; Tissier AM; Khairoune A; Vassiliu V; Méjean A; Hélénon O; Memo R; Barr RG
Radiology; 2015 Apr; 275(1):280-9. PubMed ID: 25599156
[TBL] [Abstract][Full Text] [Related]
23. Quantifying the Impact of Imaging Through Body Walls on Shear Wave Elasticity Measurements.
Zhang B; Bottenus N; Jin FQ; Nightingale KR
Ultrasound Med Biol; 2023 Mar; 49(3):734-749. PubMed ID: 36564217
[TBL] [Abstract][Full Text] [Related]
24. Comparison of Strain and Shear Wave Elastography in Prostate Cancer Detection.
Tyloch DJ; Tyloch JF; Adamowicz J; Neska-Długosz I; Grzanka D; Van Breda S; Drewa T
Ultrasound Med Biol; 2023 Mar; 49(3):889-900. PubMed ID: 36572589
[TBL] [Abstract][Full Text] [Related]
25. Multiparametric Ultrasound for Prostate Cancer Detection and Localization: Correlation of B-mode, Shear Wave Elastography and Contrast Enhanced Ultrasound with Radical Prostatectomy Specimens.
Mannaerts CK; Wildeboer RR; Remmers S; van Kollenburg RAA; Kajtazovic A; Hagemann J; Postema AW; van Sloun RJG; J Roobol M; Tilki D; Mischi M; Wijkstra H; Salomon G
J Urol; 2019 Dec; 202(6):1166-1173. PubMed ID: 31246546
[TBL] [Abstract][Full Text] [Related]
26. Performance Characteristics of Transrectal Shear Wave Elastography Imaging in the Evaluation of Clinically Localized Prostate Cancer: A Prospective Study.
Wei C; Li C; Szewczyk-Bieda M; Upreti D; Lang S; Huang Z; Nabi G
J Urol; 2018 Sep; 200(3):549-558. PubMed ID: 29605444
[TBL] [Abstract][Full Text] [Related]
27. Update on Breast Cancer Detection Using Comb-Push Ultrasound Shear Elastography.
Denis M; Bayat M; Mehrmohammadi M; Gregory A; Song P; Whaley DH; Pruthi S; Chen S; Fatemi M; Alizad A
IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Sep; 62(9):1644-50. PubMed ID: 26688871
[TBL] [Abstract][Full Text] [Related]
28. Novel application of three-dimensional shear wave elastography in the detection of clinically significant prostate cancer.
Shoji S; Hashimoto A; Nakamura T; Hiraiwa S; Sato H; Sato Y; Tajiri T; Miyajima A
Biomed Rep; 2018 Apr; 8(4):373-377. PubMed ID: 29541458
[TBL] [Abstract][Full Text] [Related]
29. Thee-Dimensional Single-Track-Location Shear Wave Elasticity Imaging.
Hollender P; Lipman SL; Trahey GE
IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Dec; 64(12):1784-1794. PubMed ID: 28885153
[TBL] [Abstract][Full Text] [Related]
30. Shear-wave elasticity imaging of a liver fibrosis mouse model using high-frequency ultrasound.
Yeh CL; Chen BR; Tseng LY; Jao P; Su TH; Li PC
IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Jul; 62(7):1295-307. PubMed ID: 26168176
[TBL] [Abstract][Full Text] [Related]
31. Comb-push ultrasound shear elastography of breast masses: initial results show promise.
Denis M; Mehrmohammadi M; Song P; Meixner DD; Fazzio RT; Pruthi S; Whaley DH; Chen S; Fatemi M; Alizad A
PLoS One; 2015; 10(3):e0119398. PubMed ID: 25774978
[TBL] [Abstract][Full Text] [Related]
32. Identifying Clinically Significant Prostate Cancers using 3-D In Vivo Acoustic Radiation Force Impulse Imaging with Whole-Mount Histology Validation.
Palmeri ML; Glass TJ; Miller ZA; Rosenzweig SJ; Buck A; Polascik TJ; Gupta RT; Brown AF; Madden J; Nightingale KR
Ultrasound Med Biol; 2016 Jun; 42(6):1251-62. PubMed ID: 26947445
[TBL] [Abstract][Full Text] [Related]
33. Multiparametric MRI in detection and staging of prostate cancer.
Boesen L
Dan Med J; 2017 Feb; 64(2):. PubMed ID: 28157066
[TBL] [Abstract][Full Text] [Related]
34. Shear wave elastography for detection of prostate cancer: a preliminary study.
Woo S; Kim SY; Cho JY; Kim SH
Korean J Radiol; 2014; 15(3):346-55. PubMed ID: 24843239
[TBL] [Abstract][Full Text] [Related]
35. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
[TBL] [Abstract][Full Text] [Related]
36. The diagnostic performance of shear wave speed (SWS) imaging for thyroid nodules with elasticity modulus and SWS measurement.
Wang D; He YP; Zhang YF; Liu BJ; Zhao CK; Fu HJ; Wei Q; Xu HX
Oncotarget; 2017 Feb; 8(8):13387-13399. PubMed ID: 28077785
[TBL] [Abstract][Full Text] [Related]
37. Dual-Phase Transmit Focusing for Multiangle Compound Shear-Wave Elasticity Imaging.
Yoon H; Aglyamov SR; Emelianov SY
IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Oct; 64(10):1439-1449. PubMed ID: 28708552
[TBL] [Abstract][Full Text] [Related]
38. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter.
Au FW; Ghai S; Moshonov H; Kahn H; Brennan C; Dua H; Crystal P
AJR Am J Roentgenol; 2014 Sep; 203(3):W328-36. PubMed ID: 25148191
[TBL] [Abstract][Full Text] [Related]
39. First experience of comparisons between two different shear wave speed imaging systems in differentiating malignant from benign thyroid nodules.
He YP; Xu HX; Wang D; Li XL; Ren WW; Zhao CK; Bo XW; Liu BJ; Yue WW
Clin Hemorheol Microcirc; 2017; 65(4):349-361. PubMed ID: 27983544
[TBL] [Abstract][Full Text] [Related]
40. A Novel Scoring System for Prediction of Prostate Cancer Based on Shear Wave Elastography and Clinical Parameters.
Su R; Xu G; Xiang L; Ding S; Wu R
Urology; 2018 Nov; 121():112-117. PubMed ID: 30171925
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]