106 related articles for article (PubMed ID: 3383417)
1. Prosthetic ball free in the left ventricle in a patient with an aortic Starr-Edwards prosthesis. Schrader DD; Sellanes MA; Laschover NK; Macchi RJ; Eserequis M; Mizraji JI; Nojek CA Cleve Clin J Med; 1988; 55(2):175-7. PubMed ID: 3383417 [No Abstract] [Full Text] [Related]
2. Excellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case. Tochii M; Takagi Y; Kaneko K; Ishida M; Akita K; Higuchi Y; Ando M Ann Thorac Cardiovasc Surg; 2013; 19(1):76-8. PubMed ID: 22785448 [TBL] [Abstract][Full Text] [Related]
3. Use of the Bentall method for replacement of an aortic Starr-Edwards ball valve prosthesis implanted 32 years previously. Yotsumoto D; Iguro Y; Ueno T; Matsumoto K; Sakata R Gen Thorac Cardiovasc Surg; 2007 Aug; 55(8):331-4. PubMed ID: 17867280 [TBL] [Abstract][Full Text] [Related]
5. [Replacement of the prosthetic aortic valve within a composite graft]. Tabayashi K; Konnai T; Tohfukuji M; Tsuru Y; Fukujyu T; Mohri H Nihon Kyobu Geka Gakkai Zasshi; 1994 Sep; 42(9):1343-5. PubMed ID: 7989794 [TBL] [Abstract][Full Text] [Related]
6. Four decades with a Starr-Edwards ball valve in the aortic position. Tutarel O; Schaefer A; Fuchs M J Heart Valve Dis; 2009 Jul; 18(4):453-4. PubMed ID: 19852151 [TBL] [Abstract][Full Text] [Related]
7. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation. Tayama K; Akashi H; Tayama E; Fukunaga S; Kawara T; Kosuga K; Aoyagi S Circ J; 2004 May; 68(5):507-8. PubMed ID: 15118298 [TBL] [Abstract][Full Text] [Related]
8. Right coronary artery occlusion by cloth from a Starr-Edwards aortic valve prosthesis. Angelini GD; Kulatilake EN; Armistead SH Thorac Cardiovasc Surg; 1984 Dec; 32(6):379-80. PubMed ID: 6084335 [TBL] [Abstract][Full Text] [Related]
9. Computer simulated "Virtual TAVR" to guide TAVR in the presence of a previous Starr-Edwards mitral prosthesis. Obaid DR; Smith D; Gilbert M; Ashraf S; Chase A J Cardiovasc Comput Tomogr; 2019; 13(1):38-40. PubMed ID: 30322774 [TBL] [Abstract][Full Text] [Related]
10. A prospective controlled trial of St. Jude versus Starr Edwards aortic and mitral valve prostheses. Murday AJ; Hochstitzky A; Mansfield J; Miles J; Taylor B; Whitley E; Treasure T Ann Thorac Surg; 2003 Jul; 76(1):66-73; discussion 73-4. PubMed ID: 12842515 [TBL] [Abstract][Full Text] [Related]
11. Fatal degeneration of the silicone rubber ball of the Starr-Edwards prosthetic aortic valve. Roberts WC; Morrow AG Am J Cardiol; 1968 Nov; 22(5):614-20. PubMed ID: 5683415 [No Abstract] [Full Text] [Related]
12. Patient with a Starr-Edwards prosthesis in the aortic position for 40 years. Miranda M; do Nascimento L; Haddad MR; Haddad WT; Haddad WT; Buffolo E J Heart Valve Dis; 2013 Sep; 22(5):648-50. PubMed ID: 24383375 [TBL] [Abstract][Full Text] [Related]
14. Double prosthetic aortic valve. Late aortic erosion by Hufnagel valve. Popma BH; Goldstein AS; Jacques J; Guenter CA Chest; 1976 Nov; 70(5):660-2. PubMed ID: 975986 [TBL] [Abstract][Full Text] [Related]
15. Reoperation for a Starr-Edwards aortic prosthetic valve 33 years after initial implantation. Misumi T; Kudo M; Koizumi K; Kumamaru H Jpn J Thorac Cardiovasc Surg; 2005 Mar; 53(3):165-8. PubMed ID: 15828300 [TBL] [Abstract][Full Text] [Related]
16. Valve dysfunction of the cloth-covered Starr-Edwards ball valve. Shiono M; Sezai A; Hata M; Iida M; Negishi N; Sezai Y Circ J; 2005 Jul; 69(7):844-9. PubMed ID: 15988111 [TBL] [Abstract][Full Text] [Related]
17. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis. Falk RH; Mackinnon J; Wainscoat J; Melikian V; Bignell AH Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913 [TBL] [Abstract][Full Text] [Related]
18. Patient Lives Almost 50 Years after Aortic Valve Replacement with a Starr-Edwards Caged-Ball Valve. Abad C; Hernández-Ramírez JM; Caballero E Tex Heart Inst J; 2016 Dec; 43(6):562. PubMed ID: 28100985 [No Abstract] [Full Text] [Related]
19. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation. Bogáts G; Kovács GS; Rudas L Circ J; 2004 Nov; 68(11):1093; author reply 1093. PubMed ID: 15523757 [No Abstract] [Full Text] [Related]
20. Performance characteristics of the Starr-Edwards Model 1260 aortic valve prosthesis beyond ten years. Miller DC; Oyer PE; Mitchell RS; Stinson EB; Jamieson SW; Baldwin JC; Shumway NE J Thorac Cardiovasc Surg; 1984 Aug; 88(2):193-207. PubMed ID: 6748713 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]