These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 3383417)

  • 1. Prosthetic ball free in the left ventricle in a patient with an aortic Starr-Edwards prosthesis.
    Schrader DD; Sellanes MA; Laschover NK; Macchi RJ; Eserequis M; Mizraji JI; Nojek CA
    Cleve Clin J Med; 1988; 55(2):175-7. PubMed ID: 3383417
    [No Abstract]   [Full Text] [Related]  

  • 2. Excellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case.
    Tochii M; Takagi Y; Kaneko K; Ishida M; Akita K; Higuchi Y; Ando M
    Ann Thorac Cardiovasc Surg; 2013; 19(1):76-8. PubMed ID: 22785448
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of the Bentall method for replacement of an aortic Starr-Edwards ball valve prosthesis implanted 32 years previously.
    Yotsumoto D; Iguro Y; Ueno T; Matsumoto K; Sakata R
    Gen Thorac Cardiovasc Surg; 2007 Aug; 55(8):331-4. PubMed ID: 17867280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An unusual lethal complication associated with Starr-Edwards prosthetic aortic valve holder.
    Nandi P; Tse TF; Ho FC; Leung JS
    Chest; 1977 Dec; 72(6):787-9. PubMed ID: 923319
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Replacement of the prosthetic aortic valve within a composite graft].
    Tabayashi K; Konnai T; Tohfukuji M; Tsuru Y; Fukujyu T; Mohri H
    Nihon Kyobu Geka Gakkai Zasshi; 1994 Sep; 42(9):1343-5. PubMed ID: 7989794
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Four decades with a Starr-Edwards ball valve in the aortic position.
    Tutarel O; Schaefer A; Fuchs M
    J Heart Valve Dis; 2009 Jul; 18(4):453-4. PubMed ID: 19852151
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.
    Tayama K; Akashi H; Tayama E; Fukunaga S; Kawara T; Kosuga K; Aoyagi S
    Circ J; 2004 May; 68(5):507-8. PubMed ID: 15118298
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Right coronary artery occlusion by cloth from a Starr-Edwards aortic valve prosthesis.
    Angelini GD; Kulatilake EN; Armistead SH
    Thorac Cardiovasc Surg; 1984 Dec; 32(6):379-80. PubMed ID: 6084335
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computer simulated "Virtual TAVR" to guide TAVR in the presence of a previous Starr-Edwards mitral prosthesis.
    Obaid DR; Smith D; Gilbert M; Ashraf S; Chase A
    J Cardiovasc Comput Tomogr; 2019; 13(1):38-40. PubMed ID: 30322774
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective controlled trial of St. Jude versus Starr Edwards aortic and mitral valve prostheses.
    Murday AJ; Hochstitzky A; Mansfield J; Miles J; Taylor B; Whitley E; Treasure T
    Ann Thorac Surg; 2003 Jul; 76(1):66-73; discussion 73-4. PubMed ID: 12842515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fatal degeneration of the silicone rubber ball of the Starr-Edwards prosthetic aortic valve.
    Roberts WC; Morrow AG
    Am J Cardiol; 1968 Nov; 22(5):614-20. PubMed ID: 5683415
    [No Abstract]   [Full Text] [Related]  

  • 12. Patient with a Starr-Edwards prosthesis in the aortic position for 40 years.
    Miranda M; do Nascimento L; Haddad MR; Haddad WT; Haddad WT; Buffolo E
    J Heart Valve Dis; 2013 Sep; 22(5):648-50. PubMed ID: 24383375
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fatal dislodgment of ball from aortic Starr--Edwards valve prosthesis.
    Düren DR; Becker AE; Wellens HJ
    Eur J Cardiol; 1975 Aug; 3(2):129-12. PubMed ID: 1183464
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Double prosthetic aortic valve. Late aortic erosion by Hufnagel valve.
    Popma BH; Goldstein AS; Jacques J; Guenter CA
    Chest; 1976 Nov; 70(5):660-2. PubMed ID: 975986
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reoperation for a Starr-Edwards aortic prosthetic valve 33 years after initial implantation.
    Misumi T; Kudo M; Koizumi K; Kumamaru H
    Jpn J Thorac Cardiovasc Surg; 2005 Mar; 53(3):165-8. PubMed ID: 15828300
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Valve dysfunction of the cloth-covered Starr-Edwards ball valve.
    Shiono M; Sezai A; Hata M; Iida M; Negishi N; Sezai Y
    Circ J; 2005 Jul; 69(7):844-9. PubMed ID: 15988111
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
    Falk RH; Mackinnon J; Wainscoat J; Melikian V; Bignell AH
    Thorax; 1979 Dec; 34(6):746-8. PubMed ID: 542913
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Patient Lives Almost 50 Years after Aortic Valve Replacement with a Starr-Edwards Caged-Ball Valve.
    Abad C; Hernández-Ramírez JM; Caballero E
    Tex Heart Inst J; 2016 Dec; 43(6):562. PubMed ID: 28100985
    [No Abstract]   [Full Text] [Related]  

  • 19. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.
    Bogáts G; Kovács GS; Rudas L
    Circ J; 2004 Nov; 68(11):1093; author reply 1093. PubMed ID: 15523757
    [No Abstract]   [Full Text] [Related]  

  • 20. Performance characteristics of the Starr-Edwards Model 1260 aortic valve prosthesis beyond ten years.
    Miller DC; Oyer PE; Mitchell RS; Stinson EB; Jamieson SW; Baldwin JC; Shumway NE
    J Thorac Cardiovasc Surg; 1984 Aug; 88(2):193-207. PubMed ID: 6748713
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.