These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

414 related articles for article (PubMed ID: 33842972)

  • 21. Diagnostic Performance of a Smart Device With Photoplethysmography Technology for Atrial Fibrillation Detection: Pilot Study (Pre-mAFA II Registry).
    Fan YY; Li YG; Li J; Cheng WK; Shan ZL; Wang YT; Guo YT
    JMIR Mhealth Uhealth; 2019 Mar; 7(3):e11437. PubMed ID: 30835243
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Diagnostic Accuracy of Ambulatory Devices in Detecting Atrial Fibrillation: Systematic Review and Meta-analysis.
    Yang TY; Huang L; Malwade S; Hsu CY; Chen YC
    JMIR Mhealth Uhealth; 2021 Apr; 9(4):e26167. PubMed ID: 33835039
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A new smart wristband equipped with an artificial intelligence algorithm to detect atrial fibrillation.
    Chen E; Jiang J; Su R; Gao M; Zhu S; Zhou J; Huo Y
    Heart Rhythm; 2020 May; 17(5 Pt B):847-853. PubMed ID: 32354449
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Real-world validation of smartphone-based photoplethysmography for rate and rhythm monitoring in atrial fibrillation.
    Gruwez H; Ezzat D; Van Puyvelde T; Dhont S; Meekers E; Bruckers L; Wouters F; Kellens M; Van Herendael H; Rivero-Ayerza M; Nuyens D; Haemers P; Pison L
    Europace; 2024 Mar; 26(4):. PubMed ID: 38630867
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Smartwatch for the Detection of Atrial Fibrillation.
    Tajrishi FZ; Chitsazan M; Chitsazan M; Shojaei F; Gunnam V; Chi G
    Crit Pathw Cardiol; 2019 Dec; 18(4):176-184. PubMed ID: 31725508
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Consumer-led screening for atrial fibrillation using consumer-facing wearables, devices and apps: A survey of health care professionals by AF-SCREEN international collaboration.
    Boriani G; Schnabel RB; Healey JS; Lopes RD; Verbiest-van Gurp N; Lobban T; Camm JA; Freedman B
    Eur J Intern Med; 2020 Dec; 82():97-104. PubMed ID: 32933842
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of a smartwatch based single-lead electrocardiogram device in detection of atrial fibrillation.
    Rajakariar K; Koshy AN; Sajeev JK; Nair S; Roberts L; Teh AW
    Heart; 2020 May; 106(9):665-670. PubMed ID: 31911507
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Implementation and validation of real-time algorithms for atrial fibrillation detection on a wearable ECG device.
    Marsili IA; Biasiolli L; Masè M; Adami A; Andrighetti AO; Ravelli F; Nollo G
    Comput Biol Med; 2020 Jan; 116():103540. PubMed ID: 31751811
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Reimbursement practices for use of digital devices in atrial fibrillation and other arrhythmias: a European Heart Rhythm Association survey.
    Boriani G; Svennberg E; Guerra F; Linz D; Casado-Arroyo R; Malaczynska-Rajpold K; Duncker D; Boveda S; Merino JL; Leclercq C
    Europace; 2022 Nov; 24(11):1834-1843. PubMed ID: 36040858
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of pulsatile photoplethysmography applications or handheld devices vs. 12-lead ECG for atrial fibrillation screening: a systematic review and meta-analysis.
    Sattar Y; Song D; Sarvepalli D; Zaidi SR; Ullah W; Arshad J; Mir T; Zghouzi M; Elgendy IY; Qureshi W; Chalfoun N; Alraies M
    J Interv Card Electrophysiol; 2022 Oct; 65(1):33-44. PubMed ID: 34775555
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Atrial Fibrillation Detection and Atrial Fibrillation Burden Estimation via Wearables.
    Zhu L; Nathan V; Kuang J; Kim J; Avram R; Olgin J; Gao J
    IEEE J Biomed Health Inform; 2022 May; 26(5):2063-2074. PubMed ID: 34855603
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The WATCH AF Trial: SmartWATCHes for Detection of Atrial Fibrillation.
    Dörr M; Nohturfft V; Brasier N; Bosshard E; Djurdjevic A; Gross S; Raichle CJ; Rhinisperger M; Stöckli R; Eckstein J
    JACC Clin Electrophysiol; 2019 Feb; 5(2):199-208. PubMed ID: 30784691
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cost-effectiveness of Screening for Atrial Fibrillation Using Wearable Devices.
    Chen W; Khurshid S; Singer DE; Atlas SJ; Ashburner JM; Ellinor PT; McManus DD; Lubitz SA; Chhatwal J
    JAMA Health Forum; 2022 Aug; 3(8):e222419. PubMed ID: 36003419
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Assessment of a standalone photoplethysmography (PPG) algorithm for detection of atrial fibrillation on wristband-derived data.
    Selder JL; Proesmans T; Breukel L; Dur O; Gielen W; van Rossum AC; Allaart CP
    Comput Methods Programs Biomed; 2020 Dec; 197():105753. PubMed ID: 32998102
    [TBL] [Abstract][Full Text] [Related]  

  • 35. NICE atrial fibrillation guideline snubs wearable technology: a missed opportunity?
    Briosa e Gala A; Pope MT; Leo M; Lobban T; Betts TR
    Clin Med (Lond); 2022 Jan; 22(1):77-82. PubMed ID: 35078798
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Feasibility of digital atrial fibrillation screening in an elderly population : The Ulm heart rhythm weeks.
    Birkemeyer R; Maisch L; Dahme T; Spieß J; Althaus K; Schneider S; Ravens U; Haase D; Schotten U
    Herzschrittmacherther Elektrophysiol; 2021 Sep; 32(3):346-352. PubMed ID: 34241681
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Sensitivity and Specificity of Wearables for Atrial Fibrillation in Elderly Populations: A Systematic Review.
    Babar F; Cheema AM; Ahmad Z; Sarfraz A; Sarfraz Z; Ashraff H; Tayyab H; Bajwa AM; Ali H; Sarfraz M; Shahzad A; Sabzwari SRA
    Curr Cardiol Rep; 2023 Jul; 25(7):761-779. PubMed ID: 37222916
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Survey of current perspectives on consumer-available digital health devices for detecting atrial fibrillation.
    Ding EY; Svennberg E; Wurster C; Duncker D; Manninger M; Lubitz SA; Dickson E; Fitzgibbons TP; Akoum N; Al-Khatib SM; Attia ZI; Ghanbari H; Marrouche NF; Mendenhall GS; Peters NS; Tarakji KG; Turakhia M; Wan EY; McManus DD
    Cardiovasc Digit Health J; 2020; 1(1):21-29. PubMed ID: 32924024
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Mobile Phone-Based Use of the Photoplethysmography Technique to Detect Atrial Fibrillation in Primary Care: Diagnostic Accuracy Study of the FibriCheck App.
    Proesmans T; Mortelmans C; Van Haelst R; Verbrugge F; Vandervoort P; Vaes B
    JMIR Mhealth Uhealth; 2019 Mar; 7(3):e12284. PubMed ID: 30916656
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.
    Vandecasteele K; De Cooman T; Gu Y; Cleeren E; Claes K; Paesschen WV; Huffel SV; Hunyadi B
    Sensors (Basel); 2017 Oct; 17(10):. PubMed ID: 29027928
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.