These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 33845357)

  • 21. Novel Stenotic Microchannels to Study Thrombus Formation in Shear Gradients: Influence of Shear Forces and Human Platelet-Related Factors.
    Lui M; Gardiner EE; Arthur JF; Pinar I; Lee WM; Ryan K; Carberry J; Andrews RK
    Int J Mol Sci; 2019 Jun; 20(12):. PubMed ID: 31216638
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD.
    Chiu WC; Girdhar G; Xenos M; Alemu Y; Soares JS; Einav S; Slepian M; Bluestein D
    J Biomech Eng; 2014 Feb; 136(2):021014. PubMed ID: 24337144
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Refining a numerical model for device-induced thrombosis and investigating the effects of non-Newtonian blood models.
    Yang L; Tobin N; Manning KB
    J Biomech; 2021 May; 120():110393. PubMed ID: 33784516
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Prothrombotic activity of cytokine-activated endothelial cells and shear-activated platelets in the setting of ventricular assist device support.
    Apostoli A; Bianchi V; Bono N; Dimasi A; Ammann KR; Moiia YR; Montisci A; Sheriff J; Bluestein D; Fiore GB; Pappalardo F; Candiani G; Redaelli A; Slepian MJ; Consolo F
    J Heart Lung Transplant; 2019 Jun; 38(6):658-667. PubMed ID: 30846234
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Shear-Mediated Platelet Activation Enhances Thrombotic Complications in Patients With LVADs and Is Reversed After Heart Transplantation.
    Consolo F; Sferrazza G; Motolone G; Pieri M; De Bonis M; Zangrillo A; Redaelli A; Slepian MJ; Pappalardo F
    ASAIO J; 2019; 65(4):e33-e35. PubMed ID: 29952802
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Thrombus on the inflow cannula of the HeartWare HVAD: an update.
    Glass CH; Christakis A; Fishbein GA; Watkins JC; Strickland KC; Mitchell RN; Padera RF
    Cardiovasc Pathol; 2019; 38():14-20. PubMed ID: 30399526
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The hemodynamics of thrombus formation in arteries.
    Ouriel K; Donayre C; Shortell CK; Cimino C; Donnelly J; Oxley D; Green RM
    J Vasc Surg; 1991 Dec; 14(6):757-62; discussion 762-3. PubMed ID: 1960805
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of inflow cannula tip design on potential parameters of blood compatibility and thrombosis.
    Wong KC; Büsen M; Benzinger C; Gäng R; Bezema M; Greatrex N; Schmitz-Rode T; Steinseifer U
    Artif Organs; 2014 Sep; 38(9):810-7. PubMed ID: 25234762
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Modeling Clot Formation of Shear-Injured Platelets in Flow by a Dissipative Particle Dynamics Method.
    Wang L; Chen Z; Zhang J; Zhang X; Wu ZJ
    Bull Math Biol; 2020 Jun; 82(7):83. PubMed ID: 32572643
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Shear Stress-Induced Total Blood Trauma in Multiple Species.
    Chan CHH; Pieper IL; Robinson CR; Friedmann Y; Kanamarlapudi V; Thornton CA
    Artif Organs; 2017 Oct; 41(10):934-947. PubMed ID: 28744884
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of rotary blood pump pulsatility on potential parameters of blood compatibility and thrombosis in inflow cannula tips.
    Wong KC; Büsen M; Benzinger C; Gäng R; Bezema M; Greatrex N; Schmitz-Rode T; Steinseifer U
    Int J Artif Organs; 2014 Dec; 37(12):875-87. PubMed ID: 25450321
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Device thrombogenicity emulation: a novel method for optimizing mechanical circulatory support device thromboresistance.
    Girdhar G; Xenos M; Alemu Y; Chiu WC; Lynch BE; Jesty J; Einav S; Slepian MJ; Bluestein D
    PLoS One; 2012; 7(3):e32463. PubMed ID: 22396768
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Computational model of device-induced thrombosis and thromboembolism.
    Goodman PD; Barlow ET; Crapo PM; Mohammad SF; Solen KA
    Ann Biomed Eng; 2005 Jun; 33(6):780-97. PubMed ID: 16078618
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The roles of sub-micron and microscale roughness on shear-driven thrombosis on titanium alloy surfaces.
    Jayaraman A; Kang J; Antaki JF; Kirby BJ
    Artif Organs; 2023 Mar; 47(3):490-501. PubMed ID: 36420933
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Platelet deposition estimation: A novel method for emulating the pump thrombosis potential of blood pumps.
    Liu GM; Zhang Y; Chen HB; Hou JF; Jin DH; Gui XM; Hu SS
    Artif Organs; 2020 May; 44(5):465-472. PubMed ID: 31853998
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A two-phase flow approach for modeling blood stasis and estimating the thrombosis potential of a ventricular assist device.
    Dai WF; Wu P; Liu GM
    Int J Artif Organs; 2021 Jul; 44(7):471-480. PubMed ID: 33258722
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements.
    Nobili M; Sheriff J; Morbiducci U; Redaelli A; Bluestein D
    ASAIO J; 2008; 54(1):64-72. PubMed ID: 18204318
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Thrombus formation patterns in the HeartMate II ventricular assist device: clinical observations can be predicted by numerical simulations.
    Chiu WC; Slepian MJ; Bluestein D
    ASAIO J; 2014; 60(2):237-40. PubMed ID: 24399065
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transient, three-dimensional flow field simulation through a mechanical, trileaflet heart valve prosthesis.
    Kaufmann TA; Linde T; Cuenca-Navalon E; Schmitz C; Hormes M; Schmitz-Rode T; Steinseifer U
    ASAIO J; 2011; 57(4):278-82. PubMed ID: 21642841
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation.
    Chen Z; Zhang J; Li T; Tran D; Griffith BP; Wu ZJ
    Artif Organs; 2020 May; 44(5):E201-E213. PubMed ID: 31849074
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.