These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 33865620)

  • 1. Extended glaze firings for porcelain-veneered zirconia: Effects on the mechanical and optical behavior.
    Rodrigues CDS; Aurélio IL; Fraga S; Kaizer MDR; Zhang Y; May LG
    Dent Mater; 2021 Jul; 37(7):1096-1106. PubMed ID: 33865620
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extended glaze firing on ceramics for hard machining: Crack healing, residual stresses, optical and microstructural aspects.
    Aurélio IL; Dorneles LS; May LG
    Dent Mater; 2017 Feb; 33(2):226-240. PubMed ID: 28069245
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Do thermal treatments affect the mechanical behavior of porcelain-veneered zirconia? A systematic review and meta-analysis.
    Rodrigues CDS; Aurélio IL; Kaizer MDR; Zhang Y; May LG
    Dent Mater; 2019 May; 35(5):807-817. PubMed ID: 30846374
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Borosilicate glass as a surface finishing alternative for improving the mechanical properties of third-generation zirconia.
    da Silva Rodrigues C; da Silva AC; Sabino CF; de Melo RM; Campos TMB
    Dent Mater; 2024 Mar; 40(3):477-483. PubMed ID: 38145923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns.
    Belli R; Frankenberger R; Appelt A; Schmitt J; Baratieri LN; Greil P; Lohbauer U
    Dent Mater; 2013 Feb; 29(2):181-90. PubMed ID: 23261021
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of Glaze Cooling Rate on Mechanical Properties of Conventional and Pressed Porcelain on Zirconia.
    Longhini D; Rocha CO; Medeiros IS; Fonseca RG; Adabo GL
    Braz Dent J; 2016; 27(5):524-531. PubMed ID: 27982228
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of slow-cooling protocol on biaxial flexural strengths of bilayered porcelain-ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) disks.
    Sawada T; Wagner V; Schille C; Spintzyk S; Schweizer E; Geis-Gerstorfer J
    Dent Mater; 2019 Feb; 35(2):270-282. PubMed ID: 30522698
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of porcelain thickness on the flexural strength and crack propagation in a bilayered zirconia system.
    Figueiredo VMG; Pereira SMB; Bressiani E; Valera MC; Bottino MA; Zhang Y; Melo RM
    J Appl Oral Sci; 2017; 25(5):566-574. PubMed ID: 29069155
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of pre-treatments on flexural strength of zirconia and debonding crack-initiation strength of veneered zirconia.
    Doi M; Yoshida K; Atsuta M; Sawase T
    J Adhes Dent; 2011 Feb; 13(1):79-84. PubMed ID: 21403938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fatigue behavior and colorimetric differences of a porcelain-veneered zirconia: effect of quantity and position of specimens during firing.
    Machado PS; Pereira GKR; Rodrigues CDS; Guilardi LF; Valandro LF; Rippe MP
    J Prosthodont Res; 2021 Jun; 65(2):202-207. PubMed ID: 33028795
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of Zirconia Core Thickness and Veneer Firing Cycle on the Biaxial Flexural Strength of Veneering Ceramic.
    Alayad AS
    J Prosthodont; 2020 Jan; 29(1):26-33. PubMed ID: 29968266
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of repetitive firings on mechanical, optical, and phase formation changes of ceramic materials.
    Ozdogan A; Tosun B
    J Prosthet Dent; 2024 Jul; 132(1):230-240. PubMed ID: 36889999
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of multiple firings on the mechanical properties and microstructure of veneering ceramics for zirconia frameworks.
    Tang X; Nakamura T; Usami H; Wakabayashi K; Yatani H
    J Dent; 2012 May; 40(5):372-80. PubMed ID: 22330322
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization of residual stresses in zirconia veneered bilayers assessed via sharp and blunt indentation.
    Wendler M; Belli R; Petschelt A; Lohbauer U
    Dent Mater; 2015 Aug; 31(8):948-57. PubMed ID: 26037789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Extended glaze firing improves flexural strength of a glass ceramic.
    Aurélio IL; Fraga S; Dorneles LS; Bottino MA; May LG
    Dent Mater; 2015 Dec; 31(12):e316-24. PubMed ID: 26599302
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of extended glaze firing on the flexural fatigue strength of hard-machined ceramics.
    Aurélio IL; Prochnow C; Guilardi LF; Ramos GF; Bottino MA; May LG
    J Prosthet Dent; 2018 Nov; 120(5):755-761. PubMed ID: 29961617
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Leucite and cooling rate effect on porcelain-zirconia mechanical behavior.
    Meirelles PD; Spigolon YO; Borba M; Benetti P
    Dent Mater; 2016 Dec; 32(12):e382-e388. PubMed ID: 27707502
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of different glaze firing protocols on the mechanical properties of CAD-CAM ceramic materials.
    Zaniboni JF; Silva AM; Alencar CM; Porto TS; Jasinevicius RG; Fortulan CA; de Campos EA
    J Prosthet Dent; 2022 Jun; 127(6):925.e1-925.e8. PubMed ID: 35469648
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of cooling protocol on mechanical properties and microstructure of dental veneering ceramics.
    Tanaka CB; Ahmad NHB; Ellakwa A; Kruzic JJ
    Dent Mater; 2019 Oct; 35(10):1498-1505. PubMed ID: 31400983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low-fusing porcelain glaze application does not damage the fatigue strength of Y-TZP.
    Zucuni CP; Pereira GKR; Dapieve KS; Rippe MP; Bottino MC; Valandro LF
    J Mech Behav Biomed Mater; 2019 Nov; 99():198-205. PubMed ID: 31374515
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.