2. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial. Serruys PW; Farooq V; Kalesan B; de Vries T; Buszman P; Linke A; Ischinger T; Klauss V; Eberli F; Wijns W; Morice MC; Di Mario C; Corti R; Antoni D; Sohn HY; Eerdmans P; Rademaker-Havinga T; van Es GA; Meier B; Jüni P; Windecker S JACC Cardiovasc Interv; 2013 Aug; 6(8):777-89. PubMed ID: 23968698 [TBL] [Abstract][Full Text] [Related]
3. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent). Vlachojannis GJ; Smits PC; Hofma SH; Togni M; Vázquez N; Valdés M; Voudris V; Slagboom T; Goy JJ; den Heijer P; van der Ent M JACC Cardiovasc Interv; 2017 Jun; 10(12):1215-1221. PubMed ID: 28579236 [TBL] [Abstract][Full Text] [Related]
4. One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries. Vlieger S; Danzi GB; Kauer F; Oemrawsingh RM; Stojkovic S; IJsselmuiden AJJ; Routledge H; Laanmets P; Roffi M; Fröbert O; Baello P; Wlodarczak A; Puentes A; Polad J; Hildick-Smith D Coron Artery Dis; 2021 Aug; 32(5):391-396. PubMed ID: 33060529 [TBL] [Abstract][Full Text] [Related]
5. Clinical outcomes with bioabsorbable polymer- versus durable polymer-based drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis. Palmerini T; Biondi-Zoccai G; Della Riva D; Mariani A; Sabaté M; Smits PC; Kaiser C; D'Ascenzo F; Frati G; Mancone M; Genereux P; Stone GW J Am Coll Cardiol; 2014 Feb; 63(4):299-307. PubMed ID: 24211507 [TBL] [Abstract][Full Text] [Related]
6. Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: The SORT OUT VII Trial. Jensen LO; Thayssen P; Maeng M; Ravkilde J; Krusell LR; Raungaard B; Junker A; Terkelsen CJ; Veien KT; Villadsen AB; Kaltoft A; Tilsted HH; Hansen KN; Aaroe J; Kristensen SD; Hansen HS; Jensen SE; Madsen M; Bøtker HE; Berencsi K; Lassen JF; Christiansen EH Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27412869 [TBL] [Abstract][Full Text] [Related]
7. Two-year clinical outcomes of zotarolimus- and everolimus-eluting durable-polymer-coated stents versus biolimus-eluting biodegradable-polymer-coated stent in patients with acute myocardial infarction with dyslipidemia after percutaneous coronary intervention: data from the KAMIR. Kim YH; Her AY; Jeong MH; Kim BK; Hong SJ; Shin DH; Kim JS; Ko YG; Choi D; Hong MK; Jang Y Heart Vessels; 2019 Feb; 34(2):237-250. PubMed ID: 30167772 [TBL] [Abstract][Full Text] [Related]
8. Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents. Lee DH; Park TK; Song YB; Chun WJ; Choi RK; Jeong JO; Im ES; Kim SW; Lee JM; Yang JH; Hahn JY; Choi SH; Choi JH; Lee SH; Gwon HC PLoS One; 2017; 12(8):e0183079. PubMed ID: 28797113 [TBL] [Abstract][Full Text] [Related]
9. Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations. Costopoulos C; Latib A; Naganuma T; Sticchi A; Ferrarello S; Regazzoli D; Chieffo A; Figini F; Carlino M; Montorfano M; Naim C; Kawaguchi M; Gerasimou A; Giannini F; Godino C; Colombo A Catheter Cardiovasc Interv; 2014 May; 83(6):889-95. PubMed ID: 23804318 [TBL] [Abstract][Full Text] [Related]
10. The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS). Wykrzykowska J; Serruys P; Buszman P; Linke A; Ischinger T; Klauss V; Eberli F; Corti R; Wijns W; Morice MC; Di Mario C; Van Geuns RJ; Van Es GA; Juni P; Windecker S EuroIntervention; 2011 Nov; 7(7):789-95. PubMed ID: 22027687 [TBL] [Abstract][Full Text] [Related]
11. Polymer-free Biolimus-A9 coated thin strut stents for patients at high bleeding risk 1-year results from the LEADERS FREE III study. Eberli FR; Stoll HP; Urban P; Morice MC; Brunel P; Maillard L; Lipiecki J; Cook S; Berland J; Hovasse T; Carrie D; Schütte D; Slama SS; Garot P Catheter Cardiovasc Interv; 2022 Feb; 99(3):593-600. PubMed ID: 34241947 [TBL] [Abstract][Full Text] [Related]
12. First clinical evidence characterizing safety and efficacy of the new CoCr Biolimus-A9 eluting stent: The Biomatrix Alpha™ registry. Menown IBA; Mamas MA; Cotton JM; Hildick-Smith D; Eberli FR; Leibundgut G; Tresukosol D; Macaya C; Copt S; Sadozai Slama S; Stoll HP Int J Cardiol Heart Vasc; 2020 Feb; 26():100472. PubMed ID: 32140552 [TBL] [Abstract][Full Text] [Related]
13. Nobori-Biolimus-Eluting Stents versus Resolute Zotarolimus-Eluting Stents in Patients Undergoing Coronary Intervention: A Propensity Score Matching. Tantawy A; Ahn CM; Shin DH; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK Yonsei Med J; 2017 Mar; 58(2):290-295. PubMed ID: 28120558 [TBL] [Abstract][Full Text] [Related]
14. Thin, Very Thin, or Ultrathin Strut Biodegradable or Durable Polymer-Coated Drug-Eluting Stents: 3-Year Outcomes of BIO-RESORT. Buiten RA; Ploumen EH; Zocca P; Doggen CJM; Danse PW; Schotborgh CE; Scholte M; van Houwelingen KG; Stoel MG; Hartmann M; Tjon Joe Gin RM; Somi S; Linssen GCM; Kok MM; von Birgelen C JACC Cardiovasc Interv; 2019 Sep; 12(17):1650-1660. PubMed ID: 31422087 [TBL] [Abstract][Full Text] [Related]
15. Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention: A Randomized Noninferiority Trial With 1-Year Follow-Up (SORT OUT VIII Trial). Maeng M; Christiansen EH; Raungaard B; Kahlert J; Terkelsen CJ; Kristensen SD; Carstensen S; Aarøe J; Jensen SE; Villadsen AB; Lassen JF; Thim T; Eftekhari A; Veien KT; Hansen KN; Junker A; Bøtker HE; Jensen LO; JACC Cardiovasc Interv; 2019 Apr; 12(7):624-633. PubMed ID: 30947936 [TBL] [Abstract][Full Text] [Related]
16. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial. Raungaard B; Christiansen EH; Bøtker HE; Hansen HS; Ravkilde J; Thuesen L; Aarøe J; Villadsen AB; Terkelsen CJ; Krusell LR; Maeng M; Kristensen SD; Veien KT; Hansen KN; Junker A; Madsen M; Andersen SL; Jensen SE; Jensen LO; JACC Cardiovasc Interv; 2017 Feb; 10(3):255-264. PubMed ID: 28109874 [TBL] [Abstract][Full Text] [Related]
17. BioMatrix Versus Orsiro Stents for Coronary Artery Disease: A Multicenter, Randomized, Open-Label Study. Yoon CH; Kwun JS; Choi YJ; Park JJ; Kang SH; Kim SH; Suh JW; Youn TJ; Kim MK; Cha KS; Lee SH; Hong BK; Rha SW; Kang WC; Lee JH; Kim SH; Chae IH Circ Cardiovasc Interv; 2023 Jan; 16(1):e012307. PubMed ID: 36475473 [TBL] [Abstract][Full Text] [Related]
18. Safety and efficacy profile of bioresorbable-polylactide-polymer-biolimus-A9-eluting stents versus durable-polymer-everolimus- and zotarolimus-eluting stents in patients with acute coronary syndrome. Jaguszewski M; Dörig M; Frangieh AH; Ghadri JR; Cammann VL; Diekmann J; Napp LC; D'Ascenzo F; Imori Y; Obeid S; Maier W; Lüscher TF; Templin C Catheter Cardiovasc Interv; 2016 Nov; 88(6):E173-E182. PubMed ID: 27377554 [TBL] [Abstract][Full Text] [Related]
19. Clinical outcomes with thin versus thick strut polymer-free biolimus-coated stents at 3 years. Eberli FR; Oldroyd KG; Urban P; Krucoff MW; Morice MC; Tanguay JF; Leon MB; Brunel P; Maillard L; Lipiecki J; Cook S; Berland J; Hovasse T; Carrié D; Schütte D; Sadozai Slama S; Garot P Open Heart; 2024 Jun; 11(1):. PubMed ID: 38890129 [TBL] [Abstract][Full Text] [Related]
20. Outcomes following implantation of the Biolimus A9-eluting BioMatrix coronary stent: Primary analysis of the e-BioMatrix registry. Urban P; Valdés M; Menown I; Eberli F; Alhaddad I; Hildick-Smith D; Iosseliani D; Roffi M; Oldroyd K; Kalloudi E; Eerdmans P; Berland J; Kleber FX; Catheter Cardiovasc Interv; 2015 Dec; 86(7):1151-60. PubMed ID: 25683225 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]