These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 33881263)

  • 1. [Intraocular pressure with miniscleral contact lenses].
    Fedotova K; Zhu W; Astakhov SY; Novikov SA; Grabovetskiy VR; Nikolaenko VP
    Vestn Oftalmol; 2021; 137(2):52-58. PubMed ID: 33881263
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypoxic Corneal Changes following Eight Hours of Scleral Contact Lens Wear.
    Vincent SJ; Alonso-Caneiro D; Collins MJ; Beanland A; Lam L; Lim CC; Loke A; Nguyen N
    Optom Vis Sci; 2016 Mar; 93(3):293-9. PubMed ID: 26760584
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Miniscleral lens wear influences corneal curvature and optics.
    Vincent SJ; Alonso-Caneiro D; Collins MJ
    Ophthalmic Physiol Opt; 2016 Mar; 36(2):100-11. PubMed ID: 26690831
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anterior eye surface changes following miniscleral contact lens wear.
    Consejo A; Behaegel J; Van Hoey M; Wolffsohn JS; Rozema JJ; Iskander DR
    Cont Lens Anterior Eye; 2019 Feb; 42(1):70-74. PubMed ID: 29980382
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraocular Pressure After 2 Hours of Small-Diameter Scleral Lens Wear.
    Nau CB; Schornack MM; McLaren JW; Sit AJ
    Eye Contact Lens; 2016 Nov; 42(6):350-353. PubMed ID: 26629960
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of contact lens induced corneal edema on Goldmann applanation tonometry measurements.
    Hamilton KE; Pye DC; Hali A; Lin C; Kam P; Ngyuen T
    J Glaucoma; 2007 Jan; 16(1):153-8. PubMed ID: 17224766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Scleral Lens Wear on Central Corneal Thickness and Intraocular Pressure in Patients With Ocular Surface Disease.
    Shahnazi KC; Isozaki VL; Chiu GB
    Eye Contact Lens; 2020 Nov; 46(6):341-347. PubMed ID: 31652178
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of Scleral Contact Lens Size and Duration of Wear on Intraocular Pressure.
    Litvin TV; Tse V; Chung L; Zhou Y; Tan B; Han Y; Lin MC
    Eye Contact Lens; 2023 Sep; 49(9):e357-e363. PubMed ID: 37418306
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Corneal changes following short-term miniscleral contact lens wear.
    Vincent SJ; Alonso-Caneiro D; Collins MJ
    Cont Lens Anterior Eye; 2014 Dec; 37(6):461-8. PubMed ID: 25199963
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of corneal edema on dynamic contour and goldmann tonometry.
    Hamilton KE; Pye DC; Kao L; Pham N; Tran AQ
    Optom Vis Sci; 2008 Jun; 85(6):451-6. PubMed ID: 18521023
    [TBL] [Abstract][Full Text] [Related]  

  • 11. IOP and Optic Nerve Head Morphology during Scleral Lens Wear.
    Walker MK; Pardon LP; Redfern R; Patel N
    Optom Vis Sci; 2020 Sep; 97(9):661-668. PubMed ID: 32932395
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of contact lens-induced corneal edema on Goldmann applanation tonometry and dynamic contour tonometry.
    Oh JH; Yoo C; Kim YY; Kim HM; Song JS
    Graefes Arch Clin Exp Ophthalmol; 2009 Mar; 247(3):371-5. PubMed ID: 18843499
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor.
    Freiberg FJ; Lindell J; Thederan LA; Leippi S; Shen Y; Klink T
    Acta Ophthalmol; 2012 Nov; 90(7):e534-9. PubMed ID: 22974389
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the Intraocular Pressure Measured Using the New Rebound Tonometer Icare ic100 and Icare TA01i or Goldmann Applanation Tonometer.
    Nakakura S; Mori E; Fujio Y; Fujisawa Y; Matsuya K; Kobayashi Y; Tabuchi H; Asaoka R; Kiuchi Y
    J Glaucoma; 2019 Feb; 28(2):172-177. PubMed ID: 30689609
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intra-ocular pressure variation associated with the wear of scleral lenses of different diameters.
    Michaud L; Samaha D; Giasson CJ
    Cont Lens Anterior Eye; 2019 Feb; 42(1):104-110. PubMed ID: 30054088
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The time course and nature of corneal oedema during sealed miniscleral contact lens wear.
    Vincent SJ; Alonso-Caneiro D; Collins MJ
    Cont Lens Anterior Eye; 2019 Feb; 42(1):49-54. PubMed ID: 29548929
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative measurement of intraocular pressure by Icare tonometry and Airpuff tonometry in healthy subjects and patients wearing therapeutic soft contact lenses.
    Anton A; Neuburger M; Böhringer D; Jordan JF
    Graefes Arch Clin Exp Ophthalmol; 2013 Jul; 251(7):1791-5. PubMed ID: 23532453
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intraocular pressure changes in neophyte scleral lens wearers: A prospective study.
    Kramer EG; Vincent SJ
    Cont Lens Anterior Eye; 2020 Dec; 43(6):609-612. PubMed ID: 32507406
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The impact of short-term fenestrated scleral lens wear on intraocular pressure.
    Cheung SY; Collins MJ; Vincent SJ
    Cont Lens Anterior Eye; 2020 Dec; 43(6):585-588. PubMed ID: 32088133
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Changes in Scleral Tonometry and Anterior Chamber Angle after Short-term Scleral Lens Wear.
    Obinwanne CJ; Echendu DC; Agbonlahor O; Dike S
    Optom Vis Sci; 2020 Sep; 97(9):720-725. PubMed ID: 32932394
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.