These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 33890856)

  • 21. Measurement of Vital Signs by Lifelight Software in Comparison to Standard of Care Multisite Development (VISION-MD): Protocol for an Observational Study.
    Wiffen L; Brown T; Brogaard Maczka A; Kapoor M; Pearce L; Chauhan M; Chauhan AJ; Saxena M;
    JMIR Res Protoc; 2023 Jan; 12():e41533. PubMed ID: 36630158
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Validation of the Omron M3 Intellisense (HEM-7051-E) upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010 in a stage 3-5 chronic kidney disease population.
    Akpolat T; Erdem E; Aydogdu T
    Kidney Blood Press Res; 2012; 35(2):82-8. PubMed ID: 21912183
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.
    Pini C; Pastori M; Baccheschi J; Omboni S; Parati G;
    Blood Press Monit; 2007 Jun; 12(3):179-84. PubMed ID: 17496468
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Validation of BP devices QardioArm
    Chahine MN; Topouchian J; Zelveian P; Hakobyan Z; Melkonyan A; Azaki A; Diab R; Harb A; Asmar R
    Med Devices (Auckl); 2018; 11():11-20. PubMed ID: 29343992
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Blood pressure measurements with the OptiBP smartphone app validated against reference auscultatory measurements.
    Schoettker P; Degott J; Hofmann G; Proença M; Bonnier G; Lemkaddem A; Lemay M; Schorer R; Christen U; Knebel JF; Wuerzner A; Burnier M; Wuerzner G
    Sci Rep; 2020 Oct; 10(1):17827. PubMed ID: 33082436
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Validation of Single Centre Pre-Mobile Atrial Fibrillation Apps for Continuous Monitoring of Atrial Fibrillation in a Real-World Setting: Pilot Cohort Study.
    Zhang H; Zhang J; Li HB; Chen YX; Yang B; Guo YT; Chen YD
    J Med Internet Res; 2019 Dec; 21(12):e14909. PubMed ID: 31793887
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of the Withings BPM Connect Device for Self-Blood Pressure Measurements in General Population - Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Topouchian J; Zelveian P; Hakobyan Z; Gharibyan H; Asmar R
    Vasc Health Risk Manag; 2022; 18():191-200. PubMed ID: 35386428
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Home blood pressure measurement: validation of the Braun BP 2550 (UG) monitor according to the ESH International Protocol.
    Nolly H; Romero M; Nolly A; Osso P; Reinoso O; Nolly M
    Blood Press Monit; 2004 Feb; 9(1):53-8. PubMed ID: 15021079
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Simulations of blood pressure and identification of atrial fibrillation and arterial stiffness using an extended Kalman filter with oscillometric pulsation measurements.
    Hullender DA; Brown OR
    Comput Methods Programs Biomed; 2021 Jan; 198():105768. PubMed ID: 33130493
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension.
    Topouchian J; Agnoletti D; Blacher J; Youssef A; Ibanez I; Khabouth J; Khawaja S; Beaino L; Asmar R
    Vasc Health Risk Manag; 2011; 7():709-17. PubMed ID: 22174581
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.
    Gholamhosseini H; Meintjes A; Baig M; Linden M
    Stud Health Technol Inform; 2016; 224():84-9. PubMed ID: 27225558
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of the COMBEI BP118A Device for Self-Blood Pressure Measurements in General Population - Validation According to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.
    Tasić N; Topouchian J; Tasic D; Kovacevic Z; Filipovic M; Asmar R
    Vasc Health Risk Manag; 2022; 18():123-129. PubMed ID: 35309162
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Validation of the QMon-20 oscillometric blood pressure monitor for professional office use in the general population according to the ANSI/ESH/ISO 81060-2:2018 protocol.
    Rico-Martín S; Sánchez-Bacaicoa M; Calderón-García JF; Labrador-Gómez PJ; De Nicolás Jiménez JM; Villa-Rincón J; Robles NR; Guijarro C; Iammarino C; Rodilla-Salas E; Sánchez Muñoz-Torrero JF
    Blood Press Monit; 2021 Oct; 26(5):393-395. PubMed ID: 34001760
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Validation of the Omron HEM-7201 upper arm blood pressure monitor, for self-measurement in a high-altitude environment, according to the European Society of Hypertension International Protocol revision 2010.
    Cho K; Tian M; Lan Y; Zhao X; Yan LL
    J Hum Hypertens; 2013 Aug; 27(8):487-91. PubMed ID: 23466876
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of Vital Signs Using Lifelight Remote Photoplethysmography: Results of the VISION-D and VISION-V Observational Studies.
    Heiden E; Jones T; Brogaard Maczka A; Kapoor M; Chauhan M; Wiffen L; Barham H; Holland J; Saxena M; Wegerif S; Brown T; Lomax M; Massey H; Rostami S; Pearce L; Chauhan A
    JMIR Form Res; 2022 Nov; 6(11):e36340. PubMed ID: 36374541
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cuffless blood pressure estimation using only a smartphone.
    Matsumura K; Rolfe P; Toda S; Yamakoshi T
    Sci Rep; 2018 May; 8(1):7298. PubMed ID: 29740088
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.
    Stergiou GS; Alpert B; Mieke S; Asmar R; Atkins N; Eckert S; Frick G; Friedman B; Graßl T; Ichikawa T; Ioannidis JP; Lacy P; McManus R; Murray A; Myers M; Palatini P; Parati G; Quinn D; Sarkis J; Shennan A; Usuda T; Wang J; Wu CO; O'Brien E
    Hypertension; 2018 Mar; 71(3):368-374. PubMed ID: 29386350
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Validation of two devices for self-measurement of brachial blood pressure according to the International Protocol of the European Society of Hypertension: the SEINEX SE-9400 and the Microlife BP 3AC1-1.
    Topouchian JA; El Assaad MA; Orobinskaia LV; El Feghali RN; Asmar RG
    Blood Press Monit; 2005 Dec; 10(6):325-31. PubMed ID: 16330959
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Validation of the Globalcare GCE603 automated blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010.
    Song C; Yu Y; Lu BC; Yan XL
    Blood Press Monit; 2020 Oct; 25(5):291-294. PubMed ID: 32898351
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.
    Stergiou GS; Alpert B; Mieke S; Asmar R; Atkins N; Eckert S; Frick G; Friedman B; Graßl T; Ichikawa T; Ioannidis JP; Lacy P; McManus R; Murray A; Myers M; Palatini P; Parati G; Quinn D; Sarkis J; Shennan A; Usuda T; Wang J; Wu CO; O'Brien E
    J Hypertens; 2018 Mar; 36(3):472-478. PubMed ID: 29384983
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.