These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 33893323)

  • 21. Prostate multimodality image registration based on B-splines and quadrature local energy.
    Mitra J; Martí R; Oliver A; Lladó X; Ghose S; Vilanova JC; Meriaudeau F
    Int J Comput Assist Radiol Surg; 2012 May; 7(3):445-54. PubMed ID: 21706302
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A PET/CT Directed, 3D Ultrasound-Guided Biopsy System for Prostate Cancer.
    Fei B; Master V; Nieh P; Akbari H; Yang X; Fenster A; Schuster D
    Prostate Cancer Imaging (2011); 2011; 6363():100-108. PubMed ID: 26866061
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A navigation system for flexible endoscopes using abdominal 3D ultrasound.
    Hoffmann R; Kaar M; Bathia A; Bathia A; Lampret A; Birkfellner W; Hummel J; Figl M
    Phys Med Biol; 2014 Sep; 59(18):5545-58. PubMed ID: 25170913
    [TBL] [Abstract][Full Text] [Related]  

  • 24. MR-targeted TRUS prostate biopsy using local reference augmentation: initial experience.
    van de Ven WJ; Venderink W; Sedelaar JP; Veltman J; Barentsz JO; Fütterer JJ; Cornel EB; Huisman HJ
    Int Urol Nephrol; 2016 Jul; 48(7):1037-45. PubMed ID: 27068817
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Trans-rectal ultrasound visibility of prostate lesions identified by magnetic resonance imaging increases accuracy of image-fusion targeted biopsies.
    Ukimura O; Marien A; Palmer S; Villers A; Aron M; de Castro Abreu AL; Leslie S; Shoji S; Matsugasumi T; Gross M; Dasgupta P; Gill IS
    World J Urol; 2015 Nov; 33(11):1669-76. PubMed ID: 25656687
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Real-time, image-based slice-to-volume registration for ultrasound-guided spinal intervention.
    De Silva T; Uneri A; Zhang X; Ketcha M; Han R; Sheth N; Martin A; Vogt S; Kleinszig G; Belzberg A; Sciubba DM; Siewerdsen JH
    Phys Med Biol; 2018 Oct; 63(21):215016. PubMed ID: 30372418
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An Approach for Live Motion Correction for TRUS-MR Prostate Fusion Biopsy using Deep Learning.
    Bhardwaj A; Mathur P; Singh T; Suryanarayana V; Son Y; Kudavelly SR; Song S; Kang H
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():2993-2996. PubMed ID: 34891874
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Automatic prostate segmentation using deep learning on clinically diverse 3D transrectal ultrasound images.
    Orlando N; Gillies DJ; Gyacskov I; Romagnoli C; D'Souza D; Fenster A
    Med Phys; 2020 Jun; 47(6):2413-2426. PubMed ID: 32166768
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A comparison of prostate tumor targeting strategies using magnetic resonance imaging-targeted, transrectal ultrasound-guided fusion biopsy.
    Martin PR; Cool DW; Fenster A; Ward AD
    Med Phys; 2018 Mar; 45(3):1018-1028. PubMed ID: 29363762
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Towards Personalized Statistical Deformable Model and Hybrid Point Matching for Robust MR-TRUS Registration.
    Wang Y; Cheng JZ; Ni D; Lin M; Qin J; Luo X; Xu M; Xie X; Heng PA
    IEEE Trans Med Imaging; 2016 Feb; 35(2):589-604. PubMed ID: 26441446
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ultrasound-guided breast biopsy using an adapted automated cone-based ultrasound scanner: a feasibility study.
    Nikolaev AV; de Jong L; Zamecnik P; Groenhuis V; Siepel FJ; Stramigioli S; Hansen HHG; de Korte CL
    Med Phys; 2023 Jun; 50(6):3475-3489. PubMed ID: 36879348
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A 3D Neurovascular Bundles Segmentation Method based on MR-TRUS Deformable Registration.
    Yang X; Rossi P; Jani AB; Mao H; Ogunleye T; Curran WJ; Liu T
    Proc SPIE Int Soc Opt Eng; 2015 Feb; 9413():. PubMed ID: 31467458
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanically constrained non-rigid MR-TRUS prostate registration using deep learning based 3D point cloud matching.
    Fu Y; Lei Y; Wang T; Patel P; Jani AB; Mao H; Curran WJ; Liu T; Yang X
    Med Image Anal; 2021 Jan; 67():101845. PubMed ID: 33129147
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pre-clinical evaluation of an image-guided in-situ Raman spectroscopy navigation system for targeted prostate cancer interventions.
    Shams R; Picot F; Grajales D; Sheehy G; Dallaire F; Birlea M; Saad F; Trudel D; Menard C; Leblond F; Kadoury S
    Int J Comput Assist Radiol Surg; 2020 May; 15(5):867-876. PubMed ID: 32227280
    [TBL] [Abstract][Full Text] [Related]  

  • 35. MRI-TRUS registration methodology for TRUS-guided HDR prostate brachytherapy.
    McGeachy P; Watt E; Husain S; Martell K; Martinez P; Sawhney S; Thind K
    J Appl Clin Med Phys; 2021 Aug; 22(8):284-294. PubMed ID: 34318581
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Technique for a hybrid system of real-time transrectal ultrasound with preoperative magnetic resonance imaging in the guidance of targeted prostate biopsy.
    Ukimura O; Hirahara N; Fujihara A; Yamada T; Iwata T; Kamoi K; Okihara K; Ito H; Nishimura T; Miki T
    Int J Urol; 2010 Oct; 17(10):890-3. PubMed ID: 20812938
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Three-Dimensional Nonrigid MR-TRUS Registration Using Dual Optimization.
    Sun Y; Yuan J; Qiu W; Rajchl M; Romagnoli C; Fenster A
    IEEE Trans Med Imaging; 2015 May; 34(5):1085-95. PubMed ID: 25438308
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A Molecular Image-directed, 3D Ultrasound-guided Biopsy System for the Prostate.
    Fei B; Schuster DM; Master V; Akbari H; Fenster A; Nieh P
    Proc SPIE Int Soc Opt Eng; 2012; 2012():. PubMed ID: 22708023
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Fully Automated Prostate Magnetic Resonance Imaging and Transrectal Ultrasound Fusion via a Probabilistic Registration Metric.
    Sparks R; Bloch BN; Feleppa E; Barratt D; Madabhushi A
    Proc SPIE Int Soc Opt Eng; 2013 Mar; 8671():86710A-. PubMed ID: 24353393
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of MRI-TRUS fusion versus cognitive registration accuracy for MRI-targeted, TRUS-guided prostate biopsy.
    Cool DW; Zhang X; Romagnoli C; Izawa JI; Romano WM; Fenster A
    AJR Am J Roentgenol; 2015 Jan; 204(1):83-91. PubMed ID: 25539241
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.