177 related articles for article (PubMed ID: 33894521)
1. Tracheal pressure generated by high-flow nasal cannula in 3D-Printed pediatric airway models.
Gray AJ; Nielsen KR; Ellington LE; Earley M; Johnson K; Smith LS; DiBlasi RM
Int J Pediatr Otorhinolaryngol; 2021 Jun; 145():110719. PubMed ID: 33894521
[TBL] [Abstract][Full Text] [Related]
2. Effect of High-Flow Nasal Cannula on Expiratory Pressure and Ventilation in Infant, Pediatric, and Adult Models.
Nielsen KR; Ellington LE; Gray AJ; Stanberry LI; Smith LS; DiBlasi RM
Respir Care; 2018 Feb; 63(2):147-157. PubMed ID: 29066588
[TBL] [Abstract][Full Text] [Related]
3. Physiological effects of high-flow nasal cannula therapy in preterm infants.
Liew Z; Fenton AC; Harigopal S; Gopalakaje S; Brodlie M; O'Brien CJ
Arch Dis Child Fetal Neonatal Ed; 2020 Jan; 105(1):87-93. PubMed ID: 31123057
[TBL] [Abstract][Full Text] [Related]
4. PEEP Generated by High-Flow Nasal Cannula in a Pediatric Model.
Ejiofor BD; Carroll RW; Bortcosh W; Kacmarek RM
Respir Care; 2019 Oct; 64(10):1240-1249. PubMed ID: 31088986
[TBL] [Abstract][Full Text] [Related]
5. Comparison of airway pressures and expired gas washout for nasal high flow versus CPAP in child airway replicas.
Duong K; Noga M; MacLean JE; Finlay WH; Martin AR
Respir Res; 2021 Nov; 22(1):289. PubMed ID: 34758818
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of a New Interface Combining High-Flow Nasal Cannula and CPAP.
Garofalo E; Bruni A; Pelaia C; Cammarota G; Murabito P; Biamonte E; Abdalla K; Longhini F; Navalesi P
Respir Care; 2019 Oct; 64(10):1231-1239. PubMed ID: 31164484
[TBL] [Abstract][Full Text] [Related]
7. The influence of flowrate and gas density on positive airway pressure for high flow nasal cannula applied to infant airway replicas.
Moore C; Rebstock D; Katz IM; Noga ML; Caillibotte G; Finlay WH; Martin AR
J Biomech; 2020 Nov; 112():110022. PubMed ID: 32942204
[TBL] [Abstract][Full Text] [Related]
8. Physiological responses and perceived comfort to high-flow nasal cannula therapy in awake adults: effects of flow magnitude and temperature.
Narang I; Carberry JC; Butler JE; Gandevia SC; Chiang AKI; Eckert DJ
J Appl Physiol (1985); 2021 Dec; 131(6):1772-1782. PubMed ID: 34709070
[TBL] [Abstract][Full Text] [Related]
9. Association Between High-Flow Nasal Cannula and End-Expiratory Esophageal Pressures in Premature Infants.
Iyer NP; Mhanna MJ
Respir Care; 2016 Mar; 61(3):285-90. PubMed ID: 26508770
[TBL] [Abstract][Full Text] [Related]
10. High flow nasal cannula for respiratory support in preterm infants.
Wilkinson D; Andersen C; O'Donnell CP; De Paoli AG; Manley BJ
Cochrane Database Syst Rev; 2016 Feb; 2(2):CD006405. PubMed ID: 26899543
[TBL] [Abstract][Full Text] [Related]
11. Positive End-Expiratory Pressure Effect of 3 High-Flow Nasal Cannula Devices.
Luo JC; Lu MS; Zhao ZH; Jiang W; Xu B; Weng L; Li T; Du B
Respir Care; 2017 Jul; 62(7):888-895. PubMed ID: 28442633
[TBL] [Abstract][Full Text] [Related]
12. Effect of High-Flow Nasal Cannula Therapy vs Continuous Positive Airway Pressure Following Extubation on Liberation From Respiratory Support in Critically Ill Children: A Randomized Clinical Trial.
Ramnarayan P; Richards-Belle A; Drikite L; Saull M; Orzechowska I; Darnell R; Sadique Z; Lester J; Morris KP; Tume LN; Davis PJ; Peters MJ; Feltbower RG; Grieve R; Thomas K; Mouncey PR; Harrison DA; Rowan KM;
JAMA; 2022 Apr; 327(16):1555-1565. PubMed ID: 35390113
[TBL] [Abstract][Full Text] [Related]
13. High flow nasal cannula for respiratory support in preterm infants.
Wilkinson D; Andersen C; O'Donnell CP; De Paoli AG
Cochrane Database Syst Rev; 2011 May; (5):CD006405. PubMed ID: 21563154
[TBL] [Abstract][Full Text] [Related]
14. High-Flow, Heated, Humidified Air Via Nasal Cannula Treats CPAP-Intolerant Children With Obstructive Sleep Apnea.
Hawkins S; Huston S; Campbell K; Halbower A
J Clin Sleep Med; 2017 Aug; 13(8):981-989. PubMed ID: 28728621
[TBL] [Abstract][Full Text] [Related]
15. Comparison of Effort of Breathing for Infants on Nasal Modes of Respiratory Support.
Kamerkar A; Hotz J; Morzov R; Newth CJL; Ross PA; Khemani RG
J Pediatr; 2017 Jun; 185():26-32.e3. PubMed ID: 28366356
[TBL] [Abstract][Full Text] [Related]
16. High-Flow Nasal Cannula versus Nasal Continuous Positive Airway Pressure for Primary Respiratory Support in Preterm Infants with Respiratory Distress: A Randomized Controlled Trial.
Murki S; Singh J; Khant C; Kumar Dash S; Oleti TP; Joy P; Kabra NS
Neonatology; 2018; 113(3):235-241. PubMed ID: 29393237
[TBL] [Abstract][Full Text] [Related]
17. High-flow nasal cannula for children not compliant with continuous positive airway pressure.
Amaddeo A; Khirani S; Frapin A; Teng T; Griffon L; Fauroux B
Sleep Med; 2019 Nov; 63():24-28. PubMed ID: 31604152
[TBL] [Abstract][Full Text] [Related]
18. Effect of HFNC flow rate, cannula size, and nares diameter on generated airway pressures: an in vitro study.
Sivieri EM; Gerdes JS; Abbasi S
Pediatr Pulmonol; 2013 May; 48(5):506-14. PubMed ID: 22825878
[TBL] [Abstract][Full Text] [Related]
19. High-flow nasal cannula versus nasal continuous positive airway pressure for respiratory support in preterm infants: a meta-analysis of randomized controlled trials.
Hong H; Li XX; Li J; Zhang ZQ
J Matern Fetal Neonatal Med; 2021 Jan; 34(2):259-266. PubMed ID: 30966839
[No Abstract] [Full Text] [Related]
20. Heated, humidified high-flow nasal cannula therapy: yet another way to deliver continuous positive airway pressure?
Kubicka ZJ; Limauro J; Darnall RA
Pediatrics; 2008 Jan; 121(1):82-8. PubMed ID: 18166560
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]