These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 3389801)

  • 1. Radiofrequency lesion generation and its effect on tissue impedance.
    Cosman ER; Rittman WJ; Nashold BS; Makachinas TT
    Appl Neurophysiol; 1988; 51(2-5):230-42. PubMed ID: 3389801
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of laser- and radiofrequency-generated dorsal root entry zone lesions in the cat.
    Elias Z; Powers SK; Bullitt E
    Appl Neurophysiol; 1988; 51(2-5):255-63. PubMed ID: 3389803
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of electrode-tissue contact on radiofrequency lesion generation.
    Avitall B; Mughal K; Hare J; Helms R; Krum D
    Pacing Clin Electrophysiol; 1997 Dec; 20(12 Pt 1):2899-910. PubMed ID: 9455749
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Theoretical aspects of radiofrequency lesions in the dorsal root entry zone.
    Cosman ER; Nashold BS; Ovelman-Levitt J
    Neurosurgery; 1984 Dec; 15(6):945-50. PubMed ID: 6514169
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size.
    Ikeda A; Nakagawa H; Lambert H; Shah DC; Fonck E; Yulzari A; Sharma T; Pitha JV; Lazzara R; Jackman WM
    Circ Arrhythm Electrophysiol; 2014 Dec; 7(6):1174-80. PubMed ID: 25381331
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Levels of the electromagnetic field in the vicinity of therapeutic devices using radiofrequency and microwaves].
    Scandurra G
    Med Lav; 1989; 80(4):335-40. PubMed ID: 2593971
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Local pathological findings in experimental dorsal root entry zone lesions performed by mechanical section, laser and radiofrequency. A comparative study.
    Broseta J; García-March G; Sánchez-Ledesma MJ; Gonçalves J; Anaya J; Torregrosa A; Urbano J; Collía F; Ludeña MD; Merchán M
    Acta Neurochir Suppl (Wien); 1988; 43():198-204. PubMed ID: 3063075
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling radiofrequency responses of realistic multi-electrode leads containing helical and straight wires.
    Kozlov M; Horner M; Kainz W
    MAGMA; 2020 Jun; 33(3):421-437. PubMed ID: 31745756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiofrequency energy-induced heating of bovine capsular tissue: Temperature changes produced by bipolar versus monopolar electrodes.
    Shellock FG
    Arthroscopy; 2001 Feb; 17(2):124-31. PubMed ID: 11172240
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A review of selected biological effects and dosimetric data useful for development of radiofrequency safety standards for human exposure.
    Tell RA; Harlen F
    J Microw Power; 1979 Dec; 14(4):405-24. PubMed ID: 397349
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computer modeling and ex vivo experiments with a (saline-linked) irrigated electrode for RF-assisted heating.
    Arenas J; Perez JJ; Trujillo M; Berjano E
    Biomed Eng Online; 2014 Dec; 13():164. PubMed ID: 25494912
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The efficacy of a two needle electrode technique in percutaneous radiofrequency rhizotomy:An investigational laboratory study in an animal model.
    Derby R; Lee CH
    Pain Physician; 2006 Jul; 9(3):207-13. PubMed ID: 16886029
    [TBL] [Abstract][Full Text] [Related]  

  • 13. IRPA/INIRC reply to Dr. G. C. Miller's comments about radiofrequency electromagnetic field exposure limits.
    Czerski P
    Health Phys; 1988 Feb; 54(2):227. PubMed ID: 3338924
    [No Abstract]   [Full Text] [Related]  

  • 14. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium.
    Haines DE; Verow AF
    Circulation; 1990 Sep; 82(3):1034-8. PubMed ID: 2393987
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrophysiologic principles of radiofrequency lesion making.
    Organ LW
    Appl Neurophysiol; 1976-1977; 39(2):69-76. PubMed ID: 1052287
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An ex vivo comparison of cooled-radiofrequency and bipolar-radiofrequency lesion size and the effect of injected fluids.
    Vallejo R; Benyamin R; Tilley DM; Kelley CA; Cedeño DL
    Reg Anesth Pain Med; 2014; 39(4):312-21. PubMed ID: 24781285
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiofrequency catheter ablation: the effect of electrode size on lesion volume in vivo.
    Langberg JJ; Lee MA; Chin MC; Rosenqvist M
    Pacing Clin Electrophysiol; 1990 Oct; 13(10):1242-8. PubMed ID: 1701538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. How coagulation zone size is underestimated in computer modeling of RF ablation by ignoring the cooling phase just after RF power is switched off.
    Irastorza RM; Trujillo M; Berjano E
    Int J Numer Method Biomed Eng; 2017 Nov; 33(11):. PubMed ID: 28146314
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Magnetic stimulation in the diagnosis of lumbosacral radiculopathy.
    Chokroverty S; Sachdeo R; Dilullo J; Duvoisin RC
    J Neurol Neurosurg Psychiatry; 1989 Jun; 52(6):767-72. PubMed ID: 2746269
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiofrequency energy-induced heating of bovine articular cartilage: evaluation of a new temperature-controlled, bipolar radiofrequency system used at different settings.
    Shellock FG
    J Knee Surg; 2002; 15(2):90-6. PubMed ID: 12013079
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.