153 related articles for article (PubMed ID: 33905608)
21. Covered versus uncovered metal stent for endoscopic drainage of a malignant distal biliary obstruction: Meta-analysis.
Yamashita Y; Tachikawa A; Shimokawa T; Yamazaki H; Itonaga M; Sakai Y; Sugiyama H; Nakai Y; Tanaka K; Isayama H; Kitano M
Dig Endosc; 2022 Jul; 34(5):938-951. PubMed ID: 35114036
[TBL] [Abstract][Full Text] [Related]
22. A Prospective Multicenter Study of a Fully Covered Metal Stent in Patients with Distal Malignant Biliary Obstruction: WATCH-2 Study.
Kogure H; Ryozawa S; Maetani I; Nakai Y; Kawakami H; Yasuda I; Mochizuki H; Iwano H; Maguchi H; Kida M; Kubota K; Mukai T; Hasebe O; Igarashi Y; Hanada K; Irisawa A; Ito K; Itoi T; Isayama H
Dig Dis Sci; 2018 Sep; 63(9):2466-2473. PubMed ID: 29218484
[TBL] [Abstract][Full Text] [Related]
23. Irradiation stents vs. conventional metal stents for unresectable malignant biliary obstruction: A multicenter trial.
Zhu HD; Guo JH; Huang M; Ji JS; Xu H; Lu J; Li HL; Wang WH; Li YL; Ni CF; Shi HB; Xiao EH; Lv WF; Sun JH; Xu K; Han GH; Du LA; Ren WX; Li MQ; Mao AW; Xiang H; Zhang KX; Min J; Zhu GY; Su C; Chen L; Teng GJ
J Hepatol; 2018 May; 68(5):970-977. PubMed ID: 29331343
[TBL] [Abstract][Full Text] [Related]
24. Biliary self-expandable metallic stent combined with iodine-125 seeds in the treatment of malignant biliary obstruction (Bismuth type I or II).
Chai J; Liu K; Xu B; Wang L; Yu H; Lv W; Lu D
Surg Endosc; 2023 Oct; 37(10):7729-7737. PubMed ID: 37566117
[TBL] [Abstract][Full Text] [Related]
25. Combined side-by-side and stent-in-stent method for triple metal stenting in patients with malignant hilar biliary obstruction.
Inoue T; Ibusuki M; Kitano R; Kobayashi Y; Ohashi T; Nakade Y; Sumida Y; Ito K; Nakao H; Yoneda M
Dig Endosc; 2019 Nov; 31(6):698-705. PubMed ID: 31120163
[TBL] [Abstract][Full Text] [Related]
26. Intraductal placement of a fully covered metal stent with a long string for distal malignant biliary obstruction without endoscopic sphincterotomy: Prospective multi-center feasibility study.
Inoue T; Suzuki Y; Okumura F; Naitoh I; Sano H; Ibusuki M; Kitano R; Kobayashi Y; Ito K; Yoneda M
Dig Endosc; 2020 Sep; 32(6):949-956. PubMed ID: 31898346
[TBL] [Abstract][Full Text] [Related]
27. Effect of ursodeoxycholic acid after self-expandable metal stent placement in malignant distal biliary obstruction: a propensity score-matched cohort analysis.
Okuno M; Iwata K; Mukai T; Ohashi Y; Iwata S; Iwasa Y; Yoshida K; Maruta A; Tezuka R; Ichikawa H; Mita N; Uemura S; Iwashita T; Tomita E; Shimizu M
Gastrointest Endosc; 2023 Apr; 97(4):713-721.e6. PubMed ID: 36328210
[TBL] [Abstract][Full Text] [Related]
28. Comparable Efficacy of Laser-Cut and Braided Self Expanding Metallic Biliary Stent: A Systematic Review and Meta-Analysis.
Loganathan P; Chandan S; Mohan BP; Saligram S; Adler DG
Dig Dis Sci; 2023 Sep; 68(9):3756-3764. PubMed ID: 37439926
[TBL] [Abstract][Full Text] [Related]
29. Evaluation of a 12-mm diameter covered self-expandable end bare metal stent for malignant biliary obstruction.
Nakaoka K; Hashimoto S; Kawabe N; Nakano T; Kan T; Ohki M; Ochi Y; Takamura T; Kurashita T; Nomura S; Koyama K; Fukui A; Yoshioka K
Endosc Int Open; 2018 Oct; 6(10):E1164-E1170. PubMed ID: 30302372
[No Abstract] [Full Text] [Related]
30. Endoscopic re-intervention after stent-in-stent versus side-by-side bilateral self-expandable metallic stent deployment.
Iwai T; Kida M; Okuwaki K; Yamauchi H; Kaneko T; Hasegawa R; Watanabe M; Kurosu T; Imaizumi H; Koizumi W
J Gastroenterol Hepatol; 2022 Jun; 37(6):1060-1066. PubMed ID: 35261069
[TBL] [Abstract][Full Text] [Related]
31. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.
Sugimoto M; Takagi T; Suzuki R; Konno N; Asama H; Watanabe K; Nakamura J; Kikuchi H; Waragai Y; Takasumi M; Sato Y; Hikichi T; Ohira H
World J Gastroenterol; 2017 Sep; 23(34):6273-6280. PubMed ID: 28974893
[TBL] [Abstract][Full Text] [Related]
32. Utility of laser-cut covered self-expandable metal stents for unresectable malignant distal biliary obstruction: a single-center experience.
Marui S; Uza N; Yamazaki H; Ota S; Nakamura T; Yoshida H; Okada H; Hirano T; Kuwada T; Sogabe Y; Tomono T; Matsumori T; Morita T; Nishikawa Y; Tsuda M; Maruno T; Shiokawa M; Kodama Y; Seno H
Endoscopy; 2020 Aug; 52(8):664-668. PubMed ID: 32316040
[TBL] [Abstract][Full Text] [Related]
33. Comparison of 8- and 10-mm diameter fully covered self-expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction.
Kawashima H; Hashimoto S; Ohno E; Ishikawa T; Morishima T; Matsubara H; Sugimoto H; Nonogaki K; Kanamori A; Hara K; Kuwahara T; Nakamura M; Miyahara R; Ishigami M; Ando M; Hirooka Y;
Dig Endosc; 2019 Jul; 31(4):439-447. PubMed ID: 30714216
[TBL] [Abstract][Full Text] [Related]
34. Antireflux covered metal stent for nonresectable distal malignant biliary obstruction: Multicenter randomized controlled trial.
Hamada T; Isayama H; Nakai Y; Iwashita T; Ito Y; Mukai T; Yagioka H; Saito T; Togawa O; Ryozawa S; Hirano K; Mizuno S; Yamamoto N; Kogure H; Yasuda I; Koike K
Dig Endosc; 2019 Sep; 31(5):566-574. PubMed ID: 30803046
[TBL] [Abstract][Full Text] [Related]
35. Revision of bilateral self-expandable metallic stents placed using the stent-in-stent technique for malignant hilar biliary obstruction.
Son JH; Lee HS; Lee SH; Bang S; Kang J; Paik WH; Ryu JK; Kim YT
Hepatobiliary Pancreat Dis Int; 2018 Oct; 17(5):437-442. PubMed ID: 30082195
[TBL] [Abstract][Full Text] [Related]
36. Can the laser-cut covered self-expandable metallic stent be the first choice for patients with unresectable distal malignant biliary obstruction? (with video).
Tanisaka Y; Mizuide M; Fujita A; Ogawa T; Katsuda H; Saito Y; Miyaguchi K; Araki R; Ryozawa S
J Hepatobiliary Pancreat Sci; 2022 May; 29(5):585-593. PubMed ID: 34390208
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of endoscopic reintervention for self-expandable metallic stent obstruction after stent-in-stent placement for malignant hilar biliary obstruction.
Okuno M; Mukai T; Iwashita T; Ichikawa H; Iwasa Y; Mita N; Yoshida K; Iwata K; Tomita E; Shimizu M
J Hepatobiliary Pancreat Sci; 2019 Jun; 26(6):211-218. PubMed ID: 30950234
[TBL] [Abstract][Full Text] [Related]
38. Long-term outcomes and risk factors of recurrent biliary obstruction after permanent endoscopic biliary stenting for choledocholithiasis in high-risk patients.
Sugiura R; Naruse H; Yamato H; Kudo T; Yamamoto Y; Hatanaka K; Ito J; Kinoshita K; Miyamoto S; Higashino M; Hayasaka S; Sakamoto N
J Dig Dis; 2020 Apr; 21(4):246-251. PubMed ID: 32223015
[TBL] [Abstract][Full Text] [Related]
39. A Case Series: Outcomes of Endoscopic Biliary Self-Expandable Metal Stent for Malignant Biliary Obstruction with Surgically Altered Anatomy.
Yamauchi H; Kida M; Okuwaki K; Miyazawa S; Iwai T; Imaizumi H; Eiji M; Hasegawa R; Koizumi W
Dig Dis Sci; 2016 Aug; 61(8):2436-2441. PubMed ID: 27033545
[TBL] [Abstract][Full Text] [Related]
40. Efficacy and Long-Term Outcomes of Side-by-Side Self-Expandable Metal Stent Placement Using a 2-Channel Endoscope for Unresectable Malignant Hilar Biliary Obstruction Occurring After Billroth II Reconstruction (with Video).
Okuwaki K; Yamauchi H; Kida M; Imaizumi H; Iwai T; Matsumoto T; Kawaguchi Y; Uehara K; Nakatani S; Koizumi W
Dig Dis Sci; 2018 Jun; 63(6):1641-1646. PubMed ID: 29557076
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]