These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 3390928)

  • 21. Centrifugal ion-selective electrode system for potassium in whole blood.
    Brackett J; Durley B; Janczak R; Kazlauskas V; Kmiec J; Norlie J; Rosencranz R; Schultz S; Spring T; Theusch W
    Clin Chem; 1990 Dec; 36(12):2126-30. PubMed ID: 2253360
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reliability of the Hitachi sodium and potassium electrodes assessed.
    Winkel P; Wilken M; Christiansen J; Buch B
    Clin Chem; 1985 Mar; 31(3):457-9. PubMed ID: 3971568
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Differences between CSF and plasma Na+ and K+ activities and concentrations.
    Johnson DC; Orlowitz L; Hitzig BM
    Am J Physiol; 1985 May; 248(5 Pt 2):R621-6. PubMed ID: 3993818
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Ion effects in measurement of ionized calcium with a calcium-selective electrode.
    Kaufman RA; Tietz NW
    Clin Chem; 1980 Apr; 26(5):640-4. PubMed ID: 6266696
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Frozen human serum reference material for standardization of sodium and potassium measurements in serum or plasma by ion-selective electrode analyzers.
    Gunaratna PC; Koch WF; Paule RC; Cormier AD; D'Orazio P; Greenberg N; O'Connell KM; Malenfant A; Okorodudu AO; Miller R
    Clin Chem; 1992 Aug; 38(8 Pt 1):1459-65. PubMed ID: 1643715
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Prevalence of Clinically Significant Differences in Sodium Measurements Due to Abnormal Protein Concentrations Using an Indirect Ion-Selective Electrode Method.
    Katrangi W; Baumann NA; Nett RC; Karon BS; Block DR
    J Appl Lab Med; 2019 Nov; 4(3):427-432. PubMed ID: 31659081
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Flame photometry determination of serum lithium. Routine method for the supervision of lithium therapy in psychiatry].
    Doerr P; Stamm D
    Z Klin Chem Klin Biochem; 1968 May; 6(3):178-82. PubMed ID: 5709558
    [No Abstract]   [Full Text] [Related]  

  • 28. Plasma sodium measurements by direct ion selective methods in laboratory and point of care may not be clinically interchangeable.
    Weld BA; Morgan TJ; Presneill JJ; Weier S; Cowley D
    J Clin Monit Comput; 2017 Oct; 31(5):1103-1109. PubMed ID: 27683272
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of methods for sodium and potassium determination in llama urine.
    Christopher MM; Belknap EB; Meyer DJ; Lackey MN; Vap LM
    Am J Vet Res; 1996 Jan; 57(1):25-30. PubMed ID: 8720233
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sweat analysis using indirect ion-selective electrode on the routine chemistry analyser meets UK guidelines.
    Hulstein JJ; van 't Sant P
    Ann Clin Biochem; 2011 Jul; 48(Pt 4):374-6. PubMed ID: 21652687
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reliability of IL Monarch ion-selective electrode module for sodium, potassium, and chloride measurements.
    Guagnellini E; Spagliardi G; Bernardi G; Stella P
    Clin Chem; 1988 Apr; 34(4):746-8. PubMed ID: 3359613
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Determination of Li, Na, K, Mg and Ca with a mechanised flame photometric micro-method. Mechanised micro-method ("injection method") of flame photometry (atomic absorption--atomic emission) for the determination of serum electrolytes and trace elements (Fe, Cu, Zn); Part I. (author's transl)].
    Berndt H; Jackwerth E
    J Clin Chem Clin Biochem; 1979 Feb; 17(2):71-6. PubMed ID: 422946
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.
    Anker P; Jenny HB; Wuthier U; Asper R; Ammann D; Simon W
    Clin Chem; 1983 Aug; 29(8):1508-12. PubMed ID: 6872210
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system.
    Dimeski G; Barnett RJ
    Crit Care Resusc; 2005 Mar; 7(1):12-5. PubMed ID: 16548813
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Patient-adapted, ion selective analysis--characteristics of a new instrument].
    Dennhardt R; Frucht U; Leuchtmann D
    Anasth Intensivther Notfallmed; 1987 Dec; 22(6):294-7. PubMed ID: 3439593
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measurements of sodium and potassium in newborns and prematures by ion-selective electrodes and flame photometry: influence of lipid and protein content of blood.
    Kau N; Günther M; Fahnenstich H; Kowalewski S; Bartmann P
    Acta Anaesthesiol Scand Suppl; 1995; 107():107-11. PubMed ID: 8599260
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of sodium and potassium with ion-selective electrodes.
    Fogh-Andersen N; Wimberley PD; Thode J; Siggaard-Andersen O
    Clin Chem; 1984 Mar; 30(3):433-6. PubMed ID: 6697490
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Lithium test-dose methodology using flame photometry: problems and alternatives.
    Palladino A; Longenecker RG; Lesko LJ
    J Clin Psychiatry; 1983 Jan; 44(1):7-9. PubMed ID: 6822488
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Characterization of a new ion selective electrode for ionized magnesium in whole blood, plasma, serum, and aqueous samples.
    Altura BT; Shirey TL; Young CC; Dell'Orfano K; Hiti J; Welsh R; Yeh Q; Barbour RL; Altura BM
    Scand J Clin Lab Invest Suppl; 1994; 217():21-36. PubMed ID: 7939382
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Reference Intervals of Serum Sodium, Potassium, and Chlorine in Chinese Han Population and Comparison of Two ISE Methods.
    Jia K; Zhang C; Huang X; Wang L; Hao X; Mu R; Pan B; Zhang J; Chen W; Xu N; Li G; Ma Y; Ma M; Guo W; Shang H
    J Clin Lab Anal; 2015 May; 29(3):226-34. PubMed ID: 24799148
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.