These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 33922239)

  • 21. Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation.
    Meng X; Sun Y; Bai W; Li Y; Tuo S; Cao L; Du M; Liu Y; Jin P; Yang J; Liu L
    Ann Transl Med; 2022 Jan; 10(2):84. PubMed ID: 35282076
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Mitral Valve Annulus Dimensions Assessment with Three-Dimensional Echocardiography Versus Computed Tomography: Implications for Transcatheter Interventions.
    Hirasawa K; Vo NM; Gegenava T; Pio SM; van Wijngaarden SE; Ajmone Marsan N; Bax JJ; Delgado V
    J Clin Med; 2021 Feb; 10(4):. PubMed ID: 33567645
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Aortic roots assessment by an automated three-dimensional transesophageal echocardiography: an intra-individual comparison.
    Zhang M; Wan L; Liu K; Wu W; Li H; Wang Y; Lu B; Wang H
    Int J Cardiovasc Imaging; 2019 Nov; 35(11):2029-2036. PubMed ID: 31297671
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Three-Dimensional Transesophageal Echocardiography as an Alternative to Multidetector Computed Tomography in Aortic Annular Diameter Measurements for Transcatheter Aortic Valve Implantation.
    Dima CN; Gaspar M; Mornos C; Mornos A; Deutsch P; Cioloca H; Cerbu S; Dinu M; Hoinoiu B; Luca CT; Petrescu L
    Biology (Basel); 2021 Feb; 10(2):. PubMed ID: 33567521
    [No Abstract]   [Full Text] [Related]  

  • 25. Impact of Methodologic Differences in Three-Dimensional Echocardiographic Measurements of the Aortic Annulus Compared with Computed Tomographic Angiography Before Transcatheter Aortic Valve Replacement.
    Khalique OK; Hamid NB; White JM; Bae DJ; Kodali SK; Nazif TM; Vahl TP; Paradis JM; George I; Leon MB; Hahn RT
    J Am Soc Echocardiogr; 2017 Apr; 30(4):414-421. PubMed ID: 27939049
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Computed tomography is better than echocardiography in predicting balloon-expandable transcutaneous implantation valve size in a real-world clinical practice single-center study.
    Medilek K; Bis J; Polansky P; Kvasnicka T; Borg A; Dusek J; Brtko M; Tuna M; Praus R; Ballon M; Stasek J; Littnerova S; Parizek P
    Echocardiography; 2023 Aug; 40(8):784-791. PubMed ID: 37417924
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement.
    Stortecky S; Heg D; Gloekler S; Wenaweser P; Windecker S; Buellesfeld L
    EuroIntervention; 2014 Jul; 10(3):339-46. PubMed ID: 24273249
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Utility of Three-Dimensional Transesophageal Echocardiography for Mitral Annular Sizing in Transcatheter Mitral Valve Replacement Procedures: A Cardiac Computed Tomographic Comparative Study.
    Coisne A; Pontana F; Aghezzaf S; Mouton S; Ridon H; Richardson M; Polge AS; Longère B; Silvestri V; Pagniez J; Bical A; Rousse N; Overtchouk P; Granada JF; Hahn RT; Modine T; Montaigne D
    J Am Soc Echocardiogr; 2020 Oct; 33(10):1245-1252.e2. PubMed ID: 32718722
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.
    Watanabe Y; Morice MC; Bouvier E; Leong T; Hayashida K; Lefèvre T; Hovasse T; Romano M; Chevalier B; Donzeau-Gouge P; Farge A; Cormier B; Garot P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):955-64. PubMed ID: 23954060
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.
    Jilaihawi H; Doctor N; Kashif M; Chakravarty T; Rafique A; Makar M; Furugen A; Nakamura M; Mirocha J; Gheorghiu M; Stegic J; Okuyama K; Sullivan DJ; Siegel R; Min JK; Gurudevan SV; Fontana GP; Cheng W; Friede G; Shiota T; Makkar RR
    J Am Coll Cardiol; 2013 Mar; 61(9):908-16. PubMed ID: 23449425
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Two-Dimensional Transesophageal Echocardiography Assessment of the Major Aortic Annulus Diameter in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Librera M; Carlomagno G; Paolillo S; Romano M; Antonini-Canterin F; D'Alto M; De Martino G; Briguori C
    J Cardiovasc Echogr; 2021; 31(1):23-28. PubMed ID: 34221882
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy and usefulness of aortic annular measurement using real-time three-dimensional transesophageal echocardiography: Comparison with direct surgical sizing.
    Nishi T; Shibayama K; Tabata M; Kato N; Noguchi M; Okumura H; Kawano Y; Nakatsuka D; Obunai K; Kobayashi Y; Watanabe H
    J Cardiol; 2018 Mar; 71(3):230-236. PubMed ID: 28986069
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.
    Mediratta A; Addetia K; Medvedofsky D; Schneider RJ; Kruse E; Shah AP; Nathan S; Paul JD; Blair JE; Ota T; Balkhy HH; Patel AR; Mor-Avi V; Lang RM
    Echocardiography; 2017 May; 34(5):690-699. PubMed ID: 28345211
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography.
    Pontone G; Andreini D; Bartorelli AL; Bertella E; Cortinovis S; Mushtaq S; Annoni A; Formenti A; Baggiano A; Conte E; Tamborini G; Muratori M; Gripari P; Bovis F; Veglia F; Foti C; Alamanni F; Ballerini G; Fiorentini C; Pepi M
    Am Heart J; 2012 Oct; 164(4):576-84. PubMed ID: 23067917
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 36. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.
    Willson AB; Webb JG; Labounty TM; Achenbach S; Moss R; Wheeler M; Thompson C; Min JK; Gurvitch R; Norgaard BL; Hague CJ; Toggweiler S; Binder R; Freeman M; Poulter R; Poulsen S; Wood DA; Leipsic J
    J Am Coll Cardiol; 2012 Apr; 59(14):1287-94. PubMed ID: 22365423
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing.
    Wang Y; Wang M; Song G; Wang W; Lv B; Wang H; Wu Y
    Eur Radiol; 2019 Jan; 29(1):259-269. PubMed ID: 29926206
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation.
    Gurvitch R; Webb JG; Yuan R; Johnson M; Hague C; Willson AB; Toggweiler S; Wood DA; Ye J; Moss R; Thompson CR; Achenbach S; Min JK; Labounty TM; Cury R; Leipsic J
    JACC Cardiovasc Interv; 2011 Nov; 4(11):1235-45. PubMed ID: 22115665
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dynamism of the aortic annulus: Effect of diastolic versus systolic CT annular measurements on device selection in transcatheter aortic valve replacement (TAVR).
    Murphy DT; Blanke P; Alaamri S; Naoum C; Rubinshtein R; Pache G; Precious B; Berger A; Raju R; Dvir D; Wood DA; Webb J; Leipsic JA
    J Cardiovasc Comput Tomogr; 2016; 10(1):37-43. PubMed ID: 26239964
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Aortic valve area calculation using 3D transesophageal echocardiography: Implications for aortic stenosis severity grading.
    Beneduce A; Capogrosso C; Moroni F; Ancona F; Falasconi G; Pannone L; Stella S; Ingallina G; Melillo F; Ancona MB; Romano Rt V; Palmisano A; Latib A; Colombo A; Montorfano M; Esposito A; Agricola E
    Echocardiography; 2020 Dec; 37(12):2071-2081. PubMed ID: 33026122
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.