These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

72 related articles for article (PubMed ID: 3392589)

  • 1. Quantitation of iodine-124 contamination in iodine-123 radiopharmaceuticals: characterization of a second dose calibrator.
    Palmer DW; Rao SA
    J Nucl Med; 1988 Jul; 29(7):1302. PubMed ID: 3392589
    [No Abstract]   [Full Text] [Related]  

  • 2. A simple method to quantitate iodine-124 contamination in iodine-123 radiopharmaceuticals.
    Palmer DW; Rao SA
    J Nucl Med; 1985 Aug; 26(8):936-40. PubMed ID: 4032037
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Solutions to problems in dose calibrator assay of iodine-123.
    Harris CC; Jaszczak RJ; Greer KL; Briner WH; Coleman RE
    Am J Physiol Imaging; 1988; 3(1):33-5. PubMed ID: 3390353
    [No Abstract]   [Full Text] [Related]  

  • 4. Dose calibrator assay of iodine-123 and indium-111 with a copper filter.
    Kowalsky RJ; Johnston RE
    J Nucl Med Technol; 1998 Jun; 26(2):94-8. PubMed ID: 9604830
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose calibrator readings due to radionuclidic impurities found in radiopharmaceuticals.
    Johnston AS; Colombetti LG; Baker SI; Pinsky SM
    Nuklearmedizin; 1980 Feb; 19(1):1-6. PubMed ID: 7402936
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calculation of 18F, 99mTc, 111In and 123I calibration factor using the penelope ionization chamber simulation method.
    Amiot MN
    Appl Radiat Isot; 2004; 60(2-4):529-33. PubMed ID: 14987697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accurate measurement of copper-67 in the presence of copper-64 contaminant using a dose calibrator.
    DeNardo GL; Kukis DL; Shen S; DeNardo SJ
    J Nucl Med; 1996 Feb; 37(2):302-6. PubMed ID: 8667066
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Measuring comparison of nuclides 131I and 57Co with Isotope-alibrator (author's transl)].
    Thieme K; Feige P
    Radiobiol Radiother (Berl); 1976; 17(1):97-9. PubMed ID: 935373
    [No Abstract]   [Full Text] [Related]  

  • 9. Accuracy of dose calibrator linearity test.
    Chu RY
    Health Phys; 1988 Jul; 55(1):95. PubMed ID: 3391784
    [No Abstract]   [Full Text] [Related]  

  • 10. Polymer gel dosimetry for the TG-43 dosimetric characterization of a new 125I interstitial brachytherapy seed.
    Papagiannis P; Pantelis E; Georgiou E; Karaiskos P; Angelopoulos A; Sakelliou L; Stiliaris S; Baltas D; Seimenis I
    Phys Med Biol; 2006 Apr; 51(8):2101-11. PubMed ID: 16585848
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a correction factor for Xe-133 vials for use with a dose calibrator.
    Gels GL; Piltingsrud HV
    J Nucl Med; 1982 Apr; 23(4):357-9. PubMed ID: 7069499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental determination of calibration settings of a commercially available radionuclide calibrator for various clinical measurement geometries and radionuclides.
    Ceccatelli A; Benassi M; D'Andrea M; De Felice P; Fazio A; Nocentini S; Strigari L
    Appl Radiat Isot; 2007 Jan; 65(1):120-5. PubMed ID: 16996744
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The use of 226Ra as a quality control check source for the beta-gamma coincidence counting of 131I.
    McCurdy DE; Hamel MA
    Health Phys; 1981 Apr; 40(4):561-4. PubMed ID: 7228709
    [No Abstract]   [Full Text] [Related]  

  • 14. Monte Carlo calculations of calibration and geometry correction factors of a radionuclide calibrator.
    Olsovcová V; Havelka M
    Appl Radiat Isot; 2006; 64(10-11):1370-4. PubMed ID: 16546399
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of characteristic x-rays on assay of I-123 by dose calibrator.
    Harris CC; Jaszczak RJ; Greer KL; Briner WH; Coleman RE
    J Nucl Med; 1984 Dec; 25(12):1367-70. PubMed ID: 6502258
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a high-resolution room temperature Si detector for use in clinical health physics.
    Anderson D; Hartman R; Gilmore R; Pruitt D
    Health Phys; 1985 Nov; 49(5):953-7. PubMed ID: 4066353
    [No Abstract]   [Full Text] [Related]  

  • 17. Measuring mixed energy gamma radionuclides using a radionuclide calibrator.
    Dubuque GL; Grant RJ; Kereiakes JG; van Tuinen RJ
    Int J Nucl Med Biol; 1976 Oct; 3(3-4):145-7. PubMed ID: 1002391
    [No Abstract]   [Full Text] [Related]  

  • 18. Effects of varying geometry on dose calibrator response: cobalt-57 and technetium-99m.
    Calhoun JM; Golas DB; Harris SG
    J Nucl Med; 1987 Sep; 28(9):1478-83. PubMed ID: 3625300
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration of coincidence counting assay of thyroidal iodine-125 by Monte Carlo simulation.
    Widman JC; Powsner ER
    Phys Med Biol; 1983 Apr; 28(4):427-30. PubMed ID: 6856677
    [No Abstract]   [Full Text] [Related]  

  • 20. [A solid-state reference sample of iodine radionuclide activity for checking radiometers and a method for its production].
    Sichkar' GA
    Med Tekh; 1993; (5):14-7. PubMed ID: 8302169
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.