BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 33926695)

  • 1. Highly sensitive determination of cadmium and lead in whole blood by electrothermal vaporization-atmospheric pressure glow discharge atomic emission spectrometry.
    Qian L; Lei Z; Peng X; Yang G; Wang Z
    Anal Chim Acta; 2021 Jun; 1162():338495. PubMed ID: 33926695
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct Ultratrace Detection of Lead in a Single Hair Using Portable Electromagnetic Heating Vaporization-Atmospheric Pressure Glow Discharge-Atomic Emission Spectrometry.
    Cai Z; Qian L; Peng X; Wang Z
    Anal Chem; 2021 Nov; 93(44):14701-14707. PubMed ID: 34704432
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dielectric barrier discharge micro-plasma emission source for the determination of lead in water samples by tungsten coil electro-thermal vaporization.
    Zheng H; Ma J; Zhu Z; Tang Z; Hu S
    Talanta; 2015 Jan; 132():106-11. PubMed ID: 25476285
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of cadmium in rice and water by tungsten coil electrothermal vaporization-atomic fluorescence spectrometry and tungsten coil electrothermal atomic absorption spectrometry after cloud point extraction.
    Wen X; Wu P; Chen L; Hou X
    Anal Chim Acta; 2009 Sep; 650(1):33-8. PubMed ID: 19720169
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrothermal vaporization for universal liquid sample introduction to dielectric barrier discharge microplasma for portable atomic emission spectrometry.
    Jiang X; Chen Y; Zheng C; Hou X
    Anal Chem; 2014 Jun; 86(11):5220-4. PubMed ID: 24830753
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow injection hydride generation and on-line W-coil trapping for electrothermal vaporization dielectric barrier discharge atomic emission spectrometric determination of trace cadmium.
    Deng Y; Li K; Hou X; Jiang X
    Talanta; 2021 Oct; 233():122516. PubMed ID: 34215131
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of tungsten coil electrothermal vaporization-Ar/H2 flame atomic fluorescence spectrometry for determination of eight traditional hydride-forming elements and cadmium without chemical vapor generation.
    Wu P; Wen X; He L; He Y; Chen M; Hou X
    Talanta; 2008 Jan; 74(4):505-11. PubMed ID: 18371668
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A miniaturized capacitively coupled plasma microtorch optical emission spectrometer and a Rh coiled-filament as small-sized electrothermal vaporization device for simultaneous determination of volatile elements from liquid microsamples: spectral and analytical characterization.
    Frentiu T; Darvasi E; Butaciu S; Ponta M; Petreus D; Mihaltan AI; Frentiu M
    Talanta; 2014 Nov; 129():72-8. PubMed ID: 25127566
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fast and Sensitive Determination of Cadmium and Selenium in Rice by Direct Sampling Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry.
    Lan G; Li X; Jia H; Yu X; Wang Z; Yao J; Mao X
    Molecules; 2022 Nov; 27(23):. PubMed ID: 36500268
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry.
    Grindlay G; Mora J; Gras L; de Loos-Vollebregt MT
    Anal Chim Acta; 2009 Oct; 652(1-2):154-60. PubMed ID: 19786176
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast Detection of Cadmium in Chocolate by Solid Sampling Electrothermal Vaporization Atomic Absorption Spectrometry and Its Application on Dietary Exposure Risk Assessment.
    Jia H; Li X; Lan G; Wang Z; Feng L; Mao X
    Molecules; 2022 Sep; 27(19):. PubMed ID: 36234728
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tungsten coil devices in atomic spectrometry: absorption, fluorescence, and emission.
    Hou X; Levine KE; Salido A; Jones BT; Ezer M; Elwood S; Simeonsson JB
    Anal Sci; 2001 Jan; 17(1):175-80. PubMed ID: 11993659
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity.
    Zhang Z; Wang Z; Li Q; Zou H; Shi Y
    Talanta; 2014 Feb; 119():613-9. PubMed ID: 24401463
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flowing Liquid Anode Atmospheric Pressure Glow Discharge as an Excitation Source for Optical Emission Spectrometry with the Improved Detectability of Ag, Cd, Hg, Pb, Tl, and Zn.
    Greda K; Swiderski K; Jamroz P; Pohl P
    Anal Chem; 2016 Sep; 88(17):8812-20. PubMed ID: 27476678
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Low-temperature electrothermal vaporization of thenoyltrifluoroacetone complex of Sc(III) and Y(III) for sample introduction in an inductively coupled plasma atomic emission spectrometry, and their determination in biological samples.
    Fan Z; Hu B; Jiang Z; Li S
    Anal Bioanal Chem; 2004 Jan; 378(2):456-9. PubMed ID: 14658024
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid and sensitive determination of Se and heavy metals in foods using electrothermal vaporization inductively coupled plasma mass spectrometry with a novel transportation system.
    Lan G; Li X; Yao J; Yu X; Liu Q; Qiu C; Mao X
    Front Nutr; 2023; 10():1201801. PubMed ID: 37351193
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.
    Lee KH; Liu SH; Jiang SJ
    Analyst; 1998 Jul; 123(7):1557-60. PubMed ID: 9830167
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Zirconia-coated graphite adsorption bar micro-extraction combined with ETV-ICP-MS for the determination of trace amounts of Cd, Hg and Pb in environmental and biological samples.
    Pu X; Jiang Z; Hu B
    J Mass Spectrom; 2006 Jul; 41(7):887-93. PubMed ID: 16810641
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Battery-Operated Atomic Emission Analyzer for Waterborne Arsenic Based on Atmospheric Pressure Glow Discharge Excitation Source.
    Yang C; He D; Zhu Z; Peng H; Liu Z; Wen G; Bai J; Zheng H; Hu S; Wang Y
    Anal Chem; 2017 Mar; 89(6):3694-3701. PubMed ID: 28205433
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Direct determination of trace elements in human serum by electrothermal vaporization ICP-AES].
    Chen SZ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2004 Nov; 24(11):1441-3. PubMed ID: 15762499
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.