  • 1. Agreement between dried blood spots and HemoCue in Tamil Nadu, India.
    Roshania RP; Mehta RV; Shete A; Bingewar R; Kulkarni S; Mahajan A; Miller G; Tarozzi A; Martorell R
    Sci Rep; 2021 Apr; 11(1):9285. PubMed ID: 33927229
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemoglobin measurement in venous blood compared with pooled and single-drop capillary blood: a method-comparison study in a controlled and survey setting in Uganda among children and women.
    Namaste SM; Baingana R; Brindle E
    Am J Clin Nutr; 2024 Apr; 119(4):949-959. PubMed ID: 38176682
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-invasive hemoglobin measurement devices require refinement to match diagnostic performance with their high level of usability and acceptability.
    Young MF; Raines K; Jameel F; Sidi M; Oliveira-Streiff S; Nwajei P; McGlamry K; Ou J; Oladele A; Suchdev PS
    PLoS One; 2021; 16(7):e0254629. PubMed ID: 34270591
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemoglobin point-of-care testing in rural Gambia: Comparing accuracy of HemoCue and Aptus with an automated hematology analyzer.
    Nass SA; Hossain I; Sanyang C; Baldeh B; Pereira DIA
    PLoS One; 2020; 15(10):e0239931. PubMed ID: 33002049
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of haemoglobin assessments by HemoCue and two automated haematology analysers in young Laotian children.
    Hinnouho GM; Barffour MA; Wessells KR; Brown KH; Kounnavong S; Chanhthavong B; Ratsavong K; Kewcharoenwong C; Hess SY
    J Clin Pathol; 2018 Jun; 71(6):532-538. PubMed ID: 29197856
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study.
    Neufeld L; García-Guerra A; Sánchez-Francia D; Newton-Sánchez O; Ramírez-Villalobos MD; Rivera-Dommarco J
    Salud Publica Mex; 2002; 44(3):219-27. PubMed ID: 12132319
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Folic acid supplementation and malaria susceptibility and severity among people taking antifolate antimalarial drugs in endemic areas.
    Crider K; Williams J; Qi YP; Gutman J; Yeung L; Mai C; Finkelstain J; Mehta S; Pons-Duran C; Menéndez C; Moraleda C; Rogers L; Daniels K; Green P
    Cochrane Database Syst Rev; 2022 Feb; 2(2022):. PubMed ID: 36321557
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Anemia Screening Methods Using Paired Venous Samples in Women of Reproductive Age in Southern India.
    Fothergill A; Crider KS; Johnson CB; Raj MP; Guetterman HM; Bose B; Rose CE; Qi YP; Williams JL; Kuriyan R; Bonam W; Finkelstein JL
    J Nutr; 2023 Jan; 152(12):2978-2992. PubMed ID: 36130238
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An evaluation of hemoglobin measurement tools and their accuracy and reliability when screening for child anemia in Rwanda: A randomized study.
    Parker M; Han Z; Abu-Haydar E; Matsiko E; Iyakaremye D; Tuyisenge L; Magaret A; Lyambabaje A
    PLoS One; 2018; 13(1):e0187663. PubMed ID: 29300737
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessing Accuracy and Precision of Hemoglobin Determination in Venous, Capillary Pool, and Single-Drop Capillary Blood Specimens Using three Different HemoCue® Hb Models: The Multicountry Hemoglobin Measurement (HEME) Study.
    Hackl LS; Karakochuk CD; Mazariegos DI; Jeremiah K; Obeid O; Ravi N; Ayana DA; Varela V; Alayón S; Dary O; Moorthy D
    J Nutr; 2024 Jul; 154(7):2326-2334. PubMed ID: 38580209
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of Point-of-Care Testing for Anemia in the Emergency Department.
    Osborn ZT; Villalba N; Derickson PR; Sewatsky TP; Wager AP; Freeman K
    Respir Care; 2019 Nov; 64(11):1343-1350. PubMed ID: 30914492
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Drops of Capillary Blood Are Not Appropriate for Hemoglobin Measurement with Point-of-Care Devices: A Comparative Study Using Drop Capillary, Pooled Capillary, and Venous Blood Samples.
    De la Cruz-Góngora V; Méndez-Gómez-Humarán I; Gaona-Pineda EB; Shamah-Levy T; Dary O
    Nutrients; 2022 Dec; 14(24):. PubMed ID: 36558505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Hemoglobin Measurements by 3 Point-of-Care Devices With Standard Laboratory Values and Reliability Regarding Decisions for Blood Transfusion.
    Johnson M; Marwick PC; Coetzee JF
    Anesth Analg; 2020 Aug; 131(2):640-649. PubMed ID: 31764158
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of anemia screening by point-of-care hemoglobin testing in patients seeking abortion.
    Shapiro KE; Buhimschi IA; Fleisher J
    Contraception; 2022 Jan; 105():51-54. PubMed ID: 34517000
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of point-of-care testing device for anemia detection: A cross-sectional method comparison study from Thailand.
    Chantkran W; Jamnarnwej P; Sritanabutr P; Arnutti P
    J Clin Lab Anal; 2021 Oct; 35(10):e23976. PubMed ID: 34427961
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A method comparison study between two hemoglobinometer models (Hemocue Hb 301 and Hb 201+) to measure hemoglobin concentrations and estimate anemia prevalence among women in Preah Vihear, Cambodia.
    Rappaport AI; Karakochuk CD; Whitfield KC; Kheang KM; Green TJ
    Int J Lab Hematol; 2017 Feb; 39(1):95-100. PubMed ID: 27997764
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reproducibility and validity of portable haemoglobinometer for the diagnosis of anaemia in children under the age of 5 years.
    da Silva Pereira A; de Castro IRR; Bezerra FF; Nogueira Neto JF; da Silva ACF
    J Nutr Sci; 2020 Jan; 9():e3. PubMed ID: 32042411
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The new HemoCue system Hb 301 for the haemoglobin measurement in pregnant women].
    Tayou Tagny C; Kouam L; Mbanya D
    Ann Biol Clin (Paris); 2008; 66(1):90-4. PubMed ID: 18227010
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intra- and inter-model reliability of Hemocue Hb 201+ and HemoCue Hb 301 devices.
    Jain A; Chowdhury N; Jain S
    Asian J Transfus Sci; 2018; 12(2):123-126. PubMed ID: 30692796
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India.
    Neogi SB; Sharma J; Pandey S; Zaidi N; Bhattacharya M; Kar R; Kar SS; Purohit A; Bandyopadhyay S; Saxena R
    BMC Health Serv Res; 2020 May; 20(1):468. PubMed ID: 32456639
    [TBL] [Abstract][Full Text] [Related]  