These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 33927509)

  • 21. Experimental investigation on the effect of drill quality on the performance of bone drilling.
    Alam K; Piya S; Al-Ghaithi A; Silberschmidth V
    Biomed Tech (Berl); 2020 Jan; 65(1):113-120. PubMed ID: 31437122
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Experimental and numerical study of ultrasonically-assisted drilling.
    Lotfi M; Amini S
    Ultrasonics; 2017 Mar; 75():185-193. PubMed ID: 27978440
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Experimental Investigation of Thrust Force, Delamination and Surface Roughness in Drilling Hybrid Structural Composites.
    Shanmugam V; Marimuthu U; Rajendran S; Veerasimman A; Basha AM; Majid MSBA; Esmaeely Neisiany R; Försth M; Sas G; Javad Razavi SM; Das O
    Materials (Basel); 2021 Aug; 14(16):. PubMed ID: 34442990
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone.
    Gupta V; Pandey PM; Gupta RK; Mridha AR
    Proc Inst Mech Eng H; 2017 Mar; 231(3):189-196. PubMed ID: 28116985
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Parametric study of bone drilling by the Kirschner wire.
    Song S; Cheng X; Li T; Shi M; Zheng G; Liu H
    Med Eng Phys; 2021 Dec; 98():115-124. PubMed ID: 34848030
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optimization of process parameters for drilled hole quality characteristics during cortical bone drilling using Taguchi method.
    Singh G; Jain V; Gupta D; Ghai A
    J Mech Behav Biomed Mater; 2016 Sep; 62():355-365. PubMed ID: 27254280
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Analysis of machining process and thermal conditions during vibration-assisted cortical bone drilling based on generated bone chip morphologies.
    Bai X; Hou S; Li K; Qu Y; Zhu W
    Med Eng Phys; 2020 Sep; 83():73-81. PubMed ID: 32807351
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An in vitro study of thermal necrosis in ultrasonic-assisted drilling of bone.
    Shakouri E; Sadeghi MH; Karafi MR; Maerefat M; Farzin M
    Proc Inst Mech Eng H; 2015 Feb; 229(2):137-49. PubMed ID: 25767150
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones.
    Singh RP; Pandey PM; Behera C; Mridha AR
    Proc Inst Mech Eng H; 2020 Aug; 234(8):829-842. PubMed ID: 32490719
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Experimental investigation of the temperature elevation in bone drilling using conventional and vibration-assisted methods.
    Bai X; Hou S; Li K; Qu Y; Zhang T
    Med Eng Phys; 2019 Jul; 69():1-7. PubMed ID: 31229386
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Augmentation of the Delamination Factor in Drilling of Carbon Fibre-Reinforced Polymer Composites (CFRP).
    Ahmad Sobri S; Whitehead D; Mohamed M; Mohamed JJ; Mohamad Amini MH; Hermawan A; Mat Rasat MS; Mohammad Sofi AZ; Wan Ismail WOAS; Norizan MN
    Polymers (Basel); 2020 Oct; 12(11):. PubMed ID: 33114223
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Thermal changes during drilling in human femur by rotary ultrasonic bone drilling machine: A histologic and ultrastructural study.
    Singh RP; Pandey PM; Mir MA; Mridha AR
    J Biomed Mater Res B Appl Biomater; 2022 May; 110(5):1023-1033. PubMed ID: 34854533
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comprehensive analysis on orthopedic drilling: A state-of-the-art review.
    Jamil M; Rafique S; Khan AM; Hegab H; Mia M; Gupta MK; Song Q
    Proc Inst Mech Eng H; 2020 Jun; 234(6):537-561. PubMed ID: 32186229
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A feasibility investigation for modeling and optimization of temperature in bone drilling using fuzzy logic and Taguchi optimization methodology.
    Pandey RK; Panda SS
    Proc Inst Mech Eng H; 2014 Nov; 228(11):1135-45. PubMed ID: 25500858
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Thermo-Mechanical and Delamination Properties in Drilling GFRP Composites by Various Drill Angles.
    Khashaba UA; Abd-Elwahed MS; Eltaher MA; Najjar I; Melaibari A; Ahmed KI
    Polymers (Basel); 2021 Jun; 13(11):. PubMed ID: 34204048
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Parametric effect of vibrational drilling on osteonecrosis and comparative histopathology study with conventional drilling of cortical bone.
    Singh G; Jain V; Gupta D; Sharma A
    Proc Inst Mech Eng H; 2018 Oct; 232(10):975-986. PubMed ID: 30112958
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An experimental investigation on thermal exposure during bone drilling.
    Lee J; Ozdoganlar OB; Rabin Y
    Med Eng Phys; 2012 Dec; 34(10):1510-20. PubMed ID: 22483188
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A predictive model for cortical bone temperature distribution during drilling.
    Hu Y; Ding H; Shi Y; Zhang H; Zheng Q
    Phys Eng Sci Med; 2021 Mar; 44(1):147-156. PubMed ID: 33459995
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Characterization of a New Dry Drill-Milling Process of Carbon Fibre Reinforced Polymer Laminates.
    Caggiano A; Improta I; Nele L
    Materials (Basel); 2018 Aug; 11(8):. PubMed ID: 30126200
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Preliminary study on rotary ultrasonic machining of CFRP/Ti stacks.
    Cong WL; Pei ZJ; Treadwell C
    Ultrasonics; 2014 Aug; 54(6):1594-602. PubMed ID: 24768497
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.