These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

66 related articles for article (PubMed ID: 3393132)

  • 1. [Management of hemoperitoneum due to rupture of visceral branches of the aorta with a cylinder-type balloon catheter].
    Akaba N; Ujiie H; Umezawa K; Miura K; Kohno M; Yamamoto Y; Sakurai K
    Nihon Geka Gakkai Zasshi; 1988 Mar; 89(3):423-30. PubMed ID: 3393132
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Guided balloon catheter for proximal hemostatic control of ruptured abdominal aortic aneurysm.
    Lapin R; Kantrowitz A; Degenshein GA
    Am Surg; 1973 May; 39(5):271-4. PubMed ID: 4700658
    [No Abstract]   [Full Text] [Related]  

  • 3. The double balloon cannula in the treatment of ruptured abdominal aneurysms.
    Hoshino S; Igari T; Iwaya F; Honda K
    Int Surg; 1983; 68(3):219-21. PubMed ID: 6662633
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Ruptured aneurysms of the sub-renal abdominal aorta].
    Cormier JM; Lagneau P
    J Chir (Paris); 1976 Sep; 112(5):115-30. PubMed ID: 1086306
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Massive spontaneous hemoperitoneum due to rupture of visceral branches of the abdominal aorta.
    Pollak EW; Michas CA
    Am Surg; 1979 Oct; 45(10):621-30. PubMed ID: 507533
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A cylinder-shaped balloon catheter for the management of dissecting aneurysms in acute stage.
    Akaba N; Ujiie H; Miura K; Sakurai K
    Herz; 1992 Dec; 17(6):390-3. PubMed ID: 1483627
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Antegradely insertable aortic balloon occlusion catheter for aortic arch repair.
    Takagi H; Hirose H; Mori Y; Iwata H; Umeda Y; Matsuno Y
    Heart Vessels; 2003 May; 18(2):75-8. PubMed ID: 12756603
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Intraluminal balloon occlusion of the aorta in traumatic massive hemorrhage].
    Bühren V; Trentz O
    Unfallchirurg; 1989 Jul; 92(7):309-13. PubMed ID: 2762815
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Surgery of abdominal aorta with horseshoe kidney].
    Lotina SL; Davidović LB; Kostić DM; Velimirović DV; Petrović PLj; Perisić-Savić MV; KovacevićN S
    Srp Arh Celok Lek; 1997; 125(1-2):36-44. PubMed ID: 17974353
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility study of a direct endo-aortic clamp balloon.
    Anzai T; Iino Y; Kumeno T; Yozu R
    ASAIO J; 2007; 53(2):136-9. PubMed ID: 17413550
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Balloon-occluded intraarterial infusion therapy for advanced uterine cervical cancer: usefulness of four-lumen double balloon catheter].
    Yamamoto K; Shimizu T; Narabayashi I
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 May; 57(6):341-3. PubMed ID: 9194365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvement in thoracic aortic pressure after proximal aortic cross-clamping by balloon occlusion of the distal aorta.
    Spence PA; Lust RM; Sun YS; Iida H; Pollock SB; Williams JM; Austin EH
    Can J Surg; 1990 Dec; 33(6):474-7. PubMed ID: 2253126
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemoperitoneum secondary to rupture of cystic artery pseudoaneurysm.
    Ghoz A; Kheir E; Kotru A; Halazun K; Kessel D; Patel JJ; Lodge JP
    Hepatobiliary Pancreat Dis Int; 2007 Jun; 6(3):321-3. PubMed ID: 17548259
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Experimental study on the usefulness of the autoperfusion balloon catheter in maintaining the blood supply to the distal organs].
    Kobayashi A; Matsui O; Ueda T; Ueda K; Takashima T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1992 May; 52(5):682-4. PubMed ID: 1508642
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Coil embolization with a hyperform occlusion balloon for an acutely ruptured wide-necked basilar tip aneurysm: case report].
    Matsumoto H; Fujita K; Miki J; Tsuji N; Terada T; Itakura T
    No Shinkei Geka; 2005 Apr; 33(4):377-81. PubMed ID: 15830545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Internal occluder techniques in ruptured abdominal aortic aneurysm/ intraaortic balloon catheter use as an occluder in ruptured abdominal aortic aneurysm].
    Tiryakioğlu O
    Anadolu Kardiyol Derg; 2007 Jun; 7(2):222; author reply 223. PubMed ID: 17513233
    [No Abstract]   [Full Text] [Related]  

  • 17. Gut feeling.
    Ayling J
    Emerg Med Serv; 2003 Nov; 32(11):37. PubMed ID: 14658209
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Protection of visceral organs with an aortic occlusion balloon catheter and by femoral perfusion in aortic arch replacement].
    Aoki A; Sangawa K
    Kyobu Geka; 2008 Mar; 61(3):191-4. PubMed ID: 18323182
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Aorto-enteric fistulas].
    Davidovic LB; Spasic DS; Lotina SI; Kostic DM; Cinara IS; Svetkovic SD; Djordic PM
    Srp Arh Celok Lek; 2001; 129(7-8):183-93. PubMed ID: 11797448
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Management of acute aortic dissections with a cylinder-type balloon catheter to close the entry.
    Akaba N; Ujiie H; Umezawa K; Miura K; Yamamoto Y; Horihoshi S; Ijima H
    J Vasc Surg; 1986 Jun; 3(6):890-4. PubMed ID: 2940378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.