259 related articles for article (PubMed ID: 33931680)
41. Fretting and Corrosion at the Backside of Modular Cobalt Chromium Acetabular Inserts: A Retrieval Analysis.
Tarity TD; Koch CN; Burket JC; Wright TM; Westrich GH
J Arthroplasty; 2017 Mar; 32(3):1033-1039. PubMed ID: 28341314
[TBL] [Abstract][Full Text] [Related]
42. Fretting and corrosion of metal liners from modular dual mobility constructs : a retrieval analysis.
Hemmerling KJ; Weitzler L; Bauer TW; Padgett DE; Wright TM
Bone Joint J; 2021 Jul; 103-B(7):1238-1246. PubMed ID: 34192940
[TBL] [Abstract][Full Text] [Related]
43. Taper Design, Head Material, and Manufacturer Affect the Onset of Fretting Under Simulated Corrosion Conditions.
Woon CYL; Wach A; Wright TM; Padgett DE
J Arthroplasty; 2020 Apr; 35(4):1117-1122. PubMed ID: 31836326
[TBL] [Abstract][Full Text] [Related]
44. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases.
Kop AM; Swarts E
J Arthroplasty; 2009 Oct; 24(7):1019-23. PubMed ID: 18835686
[TBL] [Abstract][Full Text] [Related]
45. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements.
Hallab NJ; Messina C; Skipor A; Jacobs JJ
J Orthop Res; 2004 Mar; 22(2):250-9. PubMed ID: 15013082
[TBL] [Abstract][Full Text] [Related]
46. Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study.
Higgs GB; Hanzlik JA; MacDonald DW; Gilbert JL; Rimnac CM; Kurtz SM;
J Arthroplasty; 2013 Sep; 28(8 Suppl):2-6. PubMed ID: 23910820
[TBL] [Abstract][Full Text] [Related]
47. Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system.
Brock TM; Sidaginamale R; Rushton S; Nargol AV; Bowsher JG; Savisaar C; Joyce TJ; Deehan DJ; Lord JK; Langton DJ
J Orthop Res; 2015 Dec; 33(12):1868-74. PubMed ID: 26135357
[TBL] [Abstract][Full Text] [Related]
48. The Influence of Contamination and Cleaning on the Strength of Modular Head Taper Fixation in Total Hip Arthroplasty.
Krull A; Morlock MM; Bishop NE
J Arthroplasty; 2017 Oct; 32(10):3200-3205. PubMed ID: 28625686
[TBL] [Abstract][Full Text] [Related]
49. Spontaneous modular femoral head dissociation complicating total hip arthroplasty.
Talmo CT; Sharp KG; Malinowska M; Bono JV; Ward DM; LaReau J
Orthopedics; 2014 Jun; 37(6):e592-5. PubMed ID: 24972443
[TBL] [Abstract][Full Text] [Related]
50. Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: a Retrieval Analysis.
Koch CN; Figgie M; Figgie MP; Elpers ME; Wright TM; Padgett DE
HSS J; 2017 Oct; 13(3):241-247. PubMed ID: 28983216
[TBL] [Abstract][Full Text] [Related]
51. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.
Gascoyne TC; Dyrkacz RM; Turgeon TR; Burnell CD; Wyss UP; Brandt JM
J Arthroplasty; 2014 Oct; 29(10):2049-52. PubMed ID: 24997654
[TBL] [Abstract][Full Text] [Related]
52. A multicenter retrieval study of the taper interfaces of modular hip prostheses.
Goldberg JR; Gilbert JL; Jacobs JJ; Bauer TW; Paprosky W; Leurgans S
Clin Orthop Relat Res; 2002 Aug; (401):149-61. PubMed ID: 12151892
[TBL] [Abstract][Full Text] [Related]
53. Modular to Monoblock: Difficulties of Detaching the M(2)a-Magnum(TM) Head Are Common in Metal-on-metal Revisions.
Mäntymäki H; Mäkelä KT; Vahlberg T; Hirviniemi J; Niinimäki T
Clin Orthop Relat Res; 2016 Sep; 474(9):1999-2005. PubMed ID: 26940470
[TBL] [Abstract][Full Text] [Related]
54. Adverse reactions to metal debris in metal-on-polyethylene total hip arthroplasty using a titanium-molybdenum-zirconium-iron alloy stem.
Kiran M; Boscainos PJ
J Arthroplasty; 2015 Feb; 30(2):277-81. PubMed ID: 25466166
[TBL] [Abstract][Full Text] [Related]
55. Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?
Kwon YM
J Arthroplasty; 2016 Jul; 31(7):1385-9. PubMed ID: 27118353
[TBL] [Abstract][Full Text] [Related]
56. Micromotion at the head-stem taper junction of total hip prostheses is influenced by prosthesis design-, patient- and surgeon-related factors.
Falkenberg A; Biller S; Morlock MM; Huber G
J Biomech; 2020 Jan; 98():109424. PubMed ID: 31676083
[TBL] [Abstract][Full Text] [Related]
57. Same Same but Different? 12/14 Stem and Head Tapers in Total Hip Arthroplasty.
Mueller U; Braun S; Schroeder S; Sonntag R; Kretzer JP
J Arthroplasty; 2017 Oct; 32(10):3191-3199. PubMed ID: 28552447
[TBL] [Abstract][Full Text] [Related]
58. Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.
Grupp TM; Weik T; Bloemer W; Knaebel HP
BMC Musculoskelet Disord; 2010 Jan; 11():3. PubMed ID: 20047653
[TBL] [Abstract][Full Text] [Related]
59. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study.
Royhman D; Pourzal R; Hall D; Lundberg HJ; Wimmer MA; Jacobs J; Hallab NJ; Mathew MT
J Mech Behav Biomed Mater; 2021 Jun; 118():104443. PubMed ID: 33752094
[TBL] [Abstract][Full Text] [Related]
60. In vitro fretting crevice corrosion damage of CoCrMo alloys in phosphate buffered saline: Debris generation, chemistry and distribution.
Zhu D; Liu Y; Gilbert JL
Acta Biomater; 2020 Sep; 114():449-459. PubMed ID: 32771589
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]