These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 33937699)

  • 1. Comparison of reamed long and short intramedullary nail constructs in unstable intertrochanteric femur fractures: A biomechanical study.
    Blum LE; Yee MA; Mauffrey C; Goulet JA; Perdue AM; Hake ME
    OTA Int; 2020 Jun; 3(2):e075. PubMed ID: 33937699
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Biomechanical study on the treatment of intertrochanteric fracture of A3.3 type with medial sustainable nail and proximal femoral anti-rotation nail].
    Nie SB; Li JT; Zhao YP; Zhao Z; Zhu BZ; Yan YC; Zhang LC; Tang PF
    Zhongguo Gu Shang; 2020 Dec; 33(12):1161-5. PubMed ID: 33369325
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical comparison of long, short, and extended-short nail construct for femoral intertrochanteric fractures.
    Marmor M; Elliott IS; Marshall ST; Yacoubian SV; Yacoubian SV; Herfat ST
    Injury; 2015; 46(6):963-9. PubMed ID: 25818058
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation: A study on synthetic bones.
    Ozkan K; Türkmen İ; Sahin A; Yildiz Y; Erturk S; Soylemez MS
    Indian J Orthop; 2015; 49(3):347-51. PubMed ID: 26015637
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Distal locking of short cephalomedullary nails decreases varus collapse in unstable intertrochanteric fractures - a biomechanical analysis.
    Tisherman RT; Hankins ML; Moloney GB; Tarkin IS
    Injury; 2021 Mar; 52(3):414-418. PubMed ID: 33593524
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical analysis of peri‑implant fractures in short versus long cephalomedullary implants following pertrochanteric fracture consolidation.
    Breceda A; Sands A; Zderic I; Schopper C; Schader J; Gehweiler D; Mischler D; Richards G; Gueorguiev B
    Injury; 2021 Jan; 52(1):60-65. PubMed ID: 32972726
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures.
    Kuzyk PR; Shah S; Zdero R; Olsen M; Waddell JP; Schemitsch EH
    J Trauma Acute Care Surg; 2012 Feb; 72(2):E65-70. PubMed ID: 22439235
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cost-effectiveness analysis of fixation options for intertrochanteric hip fractures.
    Swart E; Makhni EC; Macaulay W; Rosenwasser MP; Bozic KJ
    J Bone Joint Surg Am; 2014 Oct; 96(19):1612-20. PubMed ID: 25274786
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures.
    Ma JX; Wang J; Xu WG; Yu JT; Yang Y; Ma XL
    Acta Orthop Traumatol Turc; 2015; 49(4):426-32. PubMed ID: 26312472
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical Analysis of Retrograde Flexible Intramedullary Nail Constructs in a Simulated Pediatric Femur Fracture Model.
    Bland DC; Black SR; Pierce WA; Wimberly RL; Riccio AI
    J Pediatr Orthop; 2019 Jan; 39(1):22-27. PubMed ID: 28141692
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical Comparison of INTERTAN Nail and Gamma3 Nail for Intertrochanteric Fractures.
    Luo W; Fu X; Ma JX; Huang JM; Wu J; Ma XL
    Orthop Surg; 2020 Dec; 12(6):1990-1997. PubMed ID: 33215879
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is distal locking necessary? A biomechanical investigation of intramedullary nailing constructs for intertrochanteric fractures.
    Gallagher D; Adams B; El-Gendi H; Patel A; Grossman L; Berdia J; Korshunov Y; Goldman A
    J Orthop Trauma; 2013 Jul; 27(7):373-8. PubMed ID: 23249889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical analysis comparing titanium elastic nails with locked plating in two simulated pediatric femur fracture models.
    Porter SE; Booker GR; Parsell DE; Weber MD; Russell GV; Woodall J; Wagner M; Neubauer T
    J Pediatr Orthop; 2012 Sep; 32(6):587-93. PubMed ID: 22892620
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Short Versus Long Cephalomedullary Nails for Fixation of Stable Versus Unstable Intertrochanteric Femur Fractures at a Level 1 Trauma Center.
    Hulet DA; Whale CS; Beebe MJ; Rothberg DL; Gililland JM; Zhang C; Presson AP; Stuart AR; Kubiak EN
    Orthopedics; 2019 Mar; 42(2):e202-e209. PubMed ID: 30668883
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures.
    Ceynowa M; Zerdzicki K; Klosowski P; Pankowski R; Rocławski M; Mazurek T
    Clin Biomech (Bristol, Avon); 2020 Jan; 71():201-207. PubMed ID: 31775090
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of locked distal screws in retrograde nailing of osteoporotic distal femur fractures: a laboratory study using cadaver femurs.
    Tejwani NC; Park S; Iesaka K; Kummer F
    J Orthop Trauma; 2005 Jul; 19(6):380-3. PubMed ID: 16003196
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model.
    Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M
    Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The treatment of reverse obliquity intertrochanteric fractures with the intramedullary hip nail.
    Park SY; Yang KH; Yoo JH; Yoon HK; Park HW
    J Trauma; 2008 Oct; 65(4):852-7. PubMed ID: 18849802
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.