BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 33941467)

  • 1. Comparison of clinical outcomes of multiple plastic stents and covered metal stent in refractory pancreatic ductal strictures in chronic pancreatitis- a systematic review and meta-analysis.
    Sofi AA; Khan MA; Ahmad S; Khan Z; Peerzada MM; Sunguk J; Vargo J
    Pancreatology; 2021 Aug; 21(5):854-861. PubMed ID: 33941467
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fully Covered Self-Expanding Metal Stent vs Multiple Plastic Stents to Treat Benign Biliary Strictures Secondary to Chronic Pancreatitis: A Multicenter Randomized Trial.
    Ramchandani M; Lakhtakia S; Costamagna G; Tringali A; Püspöek A; Tribl B; Dolak W; Devière J; Arvanitakis M; van der Merwe S; Laleman W; Ponchon T; Lepilliez V; Gabbrielli A; Bernardoni L; Bruno MJ; Poley JW; Arnelo U; Lau J; Roy A; Bourke M; Kaffes A; Neuhaus H; Peetermans J; Rousseau M; Reddy DN
    Gastroenterology; 2021 Jul; 161(1):185-195. PubMed ID: 33741314
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preliminary study of a modified, nonflared, short, fully covered metal stent for refractory benign pancreatic duct strictures (with videos).
    Lee YN; Moon JH; Park JK; Jo SJ; Lee TH; Cha SW; Cho YD; Park SH
    Gastrointest Endosc; 2020 Apr; 91(4):826-833. PubMed ID: 31738924
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review.
    Shen Y; Liu M; Chen M; Li Y; Lu Y; Zou X
    Pancreatology; 2014; 14(2):87-90. PubMed ID: 24650959
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term follow-up after multiple plastic stenting for refractory pancreatic duct strictures in chronic pancreatitis.
    Tringali A; Bove V; Vadalà di Prampero SF; Boškoski I; Familiari P; Perri V; Costamagna G
    Endoscopy; 2019 Oct; 51(10):930-935. PubMed ID: 31378858
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Soft self-expandable metal stent to treat painful pancreatic duct strictures secondary to chronic pancreatitis: a prospective multicenter trial.
    Sherman S; Kozarek RA; Costamagna G; Reddy DN; Tarnasky P; Shah RJ; Slivka A; Fogel E; Watkins J; Delhaye M; Irani SS; Tringali A; Lakhtakia S; Kedia P; Edmundowicz S; Peetermans JA; Rousseau MJ; Devière J;
    Gastrointest Endosc; 2023 Mar; 97(3):472-481.e3. PubMed ID: 36208796
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term outcomes after temporary placement of a self-expanding fully covered metal stent for benign biliary strictures secondary to chronic pancreatitis.
    Lakhtakia S; Reddy N; Dolak W; Ponchon T; Bruno MJ; Bourke MJ; Neuhaus H; Roy A; González-Huix Lladó F; Kortan PP; Peetermans J; Rousseau M; Costamagna G; Devière J;
    Gastrointest Endosc; 2020 Feb; 91(2):361-369.e3. PubMed ID: 31494135
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Long-term outcomes of 6-mm diameter fully covered self-expandable metal stents in benign refractory pancreatic ductal stricture.
    Oh D; Lee JH; Song TJ; Park DH; Lee SK; Kim MH; Lee SS
    Dig Endosc; 2018 Jul; 30(4):508-515. PubMed ID: 29453786
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraductal fully covered self-expandable metal stent versus multiple plastic stents for treating biliary anastomotic strictures after liver transplantation.
    Sissingh NJ; de Vries BA; Inderson A; van Hoek B; van der Heide F; van Hooft JE
    Gastrointest Endosc; 2023 Apr; 97(4):704-712.e2. PubMed ID: 36460088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective group sequential study evaluating a new type of fully covered self-expandable metal stent for the treatment of benign biliary strictures (with video).
    Poley JW; Cahen DL; Metselaar HJ; van Buuren HR; Kazemier G; van Eijck CH; Haringsma J; Kuipers EJ; Bruno MJ
    Gastrointest Endosc; 2012 Apr; 75(4):783-9. PubMed ID: 22325806
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term clinical outcomes of a fully covered self-expandable metal stent for refractory pancreatic strictures in symptomatic chronic pancreatitis: An 11-year follow-up study.
    Ko SW; So H; Oh D; Song TJ; Park DH; Lee SS; Seo DW; Lee SK
    J Gastroenterol Hepatol; 2023 Mar; 38(3):460-467. PubMed ID: 36626274
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fully covered self-expanding metal stents for benign refractory pancreatic duct strictures in chronic pancreatitis.
    Korpela T; Udd M; Lindström O; Kylänpää L
    Scand J Gastroenterol; 2019 Mar; 54(3):365-370. PubMed ID: 30905221
    [No Abstract]   [Full Text] [Related]  

  • 13. Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration.
    Moon SH; Kim MH; Park DH; Song TJ; Eum J; Lee SS; Seo DW; Lee SK
    Gastrointest Endosc; 2010 Jul; 72(1):86-91. PubMed ID: 20493483
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility and safety of placement of a newly designed, fully covered self-expandable metal stent for refractory benign pancreatic ductal strictures: a pilot study (with video).
    Park DH; Kim MH; Moon SH; Lee SS; Seo DW; Lee SK
    Gastrointest Endosc; 2008 Dec; 68(6):1182-9. PubMed ID: 19028228
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multiple stenting of refractory pancreatic duct strictures in severe chronic pancreatitis: long-term results.
    Costamagna G; Bulajic M; Tringali A; Pandolfi M; Gabbrielli A; Spada C; Petruzziello L; Familiari P; Mutignani M
    Endoscopy; 2006 Mar; 38(3):254-9. PubMed ID: 16528652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Management of Benign Biliary Stricture in Chronic Pancreatitis.
    Ramchandani M; Pal P; Costamagna G
    Gastrointest Endosc Clin N Am; 2023 Oct; 33(4):831-844. PubMed ID: 37709414
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Self-Expandable Metallic Stent Is More Cost Efficient Than Plastic Stent in Treating Anastomotic Biliary Stricture.
    Jang S; Stevens T; Lopez R; Chahal P; Bhatt A; Sanaka M; Vargo JJ
    Dig Dis Sci; 2020 Feb; 65(2):600-608. PubMed ID: 31104197
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficacy of fully covered self-expandable metal stents for the management of pancreatic duct strictures in chronic pancreatitis: A systematic review and meta-analysis.
    Li TT; Song SL; Xiao LN; Wang CH
    J Gastroenterol Hepatol; 2020 Jul; 35(7):1099-1106. PubMed ID: 31900986
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pilot Study of Dumbbell-Type Covered Self-Expandable Metal Stent Deployment for Benign Pancreatic Duct Stricture (with Videos).
    Yamada T; Ogura T; Okuda A; Imanishi M; Kamiyama R; Miyano A; Nishioka N; Higuchi K
    J Gastrointest Surg; 2018 Dec; 22(12):2194-2200. PubMed ID: 30084065
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Self-expanding metallic stent for refractory pancreatic duct stricture in chronic pancreatitis: A prospective follow-up study.
    Rai P; Kumar P; Kumar A; Asari S; Agarwal K; Mayank ; Krishna Kishore RV; Mishra P
    Indian J Gastroenterol; 2023 Sep; ():. PubMed ID: 37768445
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.