These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 33946509)

  • 21. Determination of Cu, As, Hg and Pb in vegetable oils by electrothermal vaporization inductively coupled plasma mass spectrometry with palladium nanoparticles as modifier.
    Hsu WH; Jiang SJ; Sahayam AC
    Talanta; 2013 Dec; 117():268-72. PubMed ID: 24209340
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Interface-free integration of electrothermal vaporizer and point discharge microplasma for miniaturized optical emission spectrometer.
    Deng Y; Hu J; Li M; He L; Li K; Hou X; Jiang X
    Anal Chim Acta; 2021 Jun; 1163():338502. PubMed ID: 34024418
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Development of gas-phase sample-introduction techniques for analytical atomic spectrometry.
    Nakahara T
    Anal Sci; 2005 May; 21(5):477-84. PubMed ID: 15913132
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Determination of As, Sb, Bi, Cd and Sn in soils and sediments by inductively coupled plasma atomic emission spectrometry after sublimation separation as iodides].
    He HL; Hu MY; Gong AH; Wen HL; Que SJ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Mar; 28(3):663-6. PubMed ID: 18536437
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of refractory elements in atmospheric particulates using slurry sampling electrothermal vaporization inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry with polyvinylidene fluoride as chemical modifier.
    Zhang Y; Jiang Z; Hu B
    Rapid Commun Mass Spectrom; 2006; 20(14):2091-8. PubMed ID: 16773674
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Determination of inorganic contaminants in glue by inductively coupled argon plasma optical emission spectrometry.
    Matoso E; Cadore S
    Talanta; 2011 Apr; 84(2):335-40. PubMed ID: 21376954
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Solid-Sampling Electrothermal Vaporization Inductively Coupled Plasma Optical Emission Spectrometry for Direct Determination of Total Oxygen in Coal.
    Vogt T; Bauer D; Nennstiel D; Otto M
    Anal Chem; 2015 Oct; 87(20):10414-20. PubMed ID: 26372175
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Direct inductively coupled plasma-atomic emission spectrometry analysis of trace elements in muscle tissues of hairtail using electrothermal vaporization with slurry sampling.
    Chen S; Lu D; Hu Z
    J AOAC Int; 2007; 90(1):258-62. PubMed ID: 17373458
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Simultaneous speciation of inorganic selenium and antimony in water samples by electrothermal vaporization inductively coupled plasma mass spectrometry following selective cloud point extraction.
    Li Y; Hu B; He M; Xiang G
    Water Res; 2008 Feb; 42(4-5):1195-203. PubMed ID: 17904192
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Optimization of the electrothermal vaporization conditions for inductively coupled plasma excitation spectrometry: Selective volatilization versus covolatilization approaches.
    Kántor T
    Anal Bioanal Chem; 1996 Jun; 355(5-6):606-14. PubMed ID: 15045325
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Electrothermal vaporization inductively coupled plasma atomic emission spectrometry determination of gold, palladium, and platinum using chelating resin YPA(4) as both extractant and chemical modifier.
    Wu Y; Jiang Z; Hu B; Duan J
    Talanta; 2004 Jun; 63(3):585-92. PubMed ID: 18969473
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Direct determination of major elements in solid plant materials by electrothermal vaporization inductively coupled plasma atomic emission spectrometry.
    Masson P
    Talanta; 2007 Feb; 71(3):1399-404. PubMed ID: 19071464
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.
    Lee KH; Liu SH; Jiang SJ
    Analyst; 1998 Jul; 123(7):1557-60. PubMed ID: 9830167
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Headspace trapping of the hydrides on a Pd(II)-coated graphite adsorptive bar as a microextraction method for ETV-ICP-MS determination of Se, Te and Bi in seawater and human hair samples.
    Xiong C; Hu B
    Talanta; 2010 Apr; 81(1-2):578-85. PubMed ID: 20188965
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of tungsten coil electrothermal vaporization and thermospray sample introduction methods for flame furnace atomic absorption spectrometry.
    Wu P; Zhang Y; Liu R; Lv Y; Hou X
    Talanta; 2009 Mar; 77(5):1778-82. PubMed ID: 19159798
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The use of electrothermal vaporizer coupled to the inductively coupled plasma mass spectrometry for the determination of arsenic, selenium and transition metals in biological samples treated with formic acid.
    Tormen L; Gil RA; Frescura VL; Martinez LD; Curtius AJ
    Anal Chim Acta; 2012 Mar; 717():21-7. PubMed ID: 22304812
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Feasibility of Rare Earth Element Determination in Low Concentration in Crude Oil: Direct Sampling Electrothermal Vaporization-Inductively Coupled Plasma Mass Spectrometry.
    Silva JS; Schneider Henn A; Dressler VL; Mello PA; Flores EMM
    Anal Chem; 2018 Jun; 90(11):7064-7071. PubMed ID: 29706063
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of 28 selected elements in textiles by axially viewed inductively coupled plasma optical emission spectrometry.
    Rezić I; Zeiner M; Steffan I
    Talanta; 2011 Jan; 83(3):865-71. PubMed ID: 21147330
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Inductively coupled plasma mass spectrometry for the simultaneous determination of thirty metals and metalloids elements in blood samples].
    Ding CG; Zhu C; Liu DY; Dong M; Zhang AH; Pan YJ; Yan HF
    Zhonghua Yu Fang Yi Xue Za Zhi; 2012 Aug; 46(8):745-9. PubMed ID: 23157872
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Flow injection hydride generation and on-line W-coil trapping for electrothermal vaporization dielectric barrier discharge atomic emission spectrometric determination of trace cadmium.
    Deng Y; Li K; Hou X; Jiang X
    Talanta; 2021 Oct; 233():122516. PubMed ID: 34215131
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.