These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 33948453)

  • 1. A set of electroencephalographic (EEG) data recorded during amplitude-modulated transcranial alternating current stimulation (AM-tACS) targeting 10-Hz steady-state visually evoked potentials (SSVEP).
    Haslacher D; Nasr K; Robinson SE; Braun C; Soekadar SR
    Data Brief; 2021 Jun; 36():107011. PubMed ID: 33948453
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stimulation artifact source separation (SASS) for assessing electric brain oscillations during transcranial alternating current stimulation (tACS).
    Haslacher D; Nasr K; Robinson SE; Braun C; Soekadar SR
    Neuroimage; 2021 Mar; 228():117571. PubMed ID: 33412281
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-linear transfer characteristics of stimulation and recording hardware account for spurious low-frequency artifacts during amplitude modulated transcranial alternating current stimulation (AM-tACS).
    Kasten FH; Negahbani E; Fröhlich F; Herrmann CS
    Neuroimage; 2018 Oct; 179():134-143. PubMed ID: 29860086
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo phase-dependent enhancement and suppression of human brain oscillations by transcranial alternating current stimulation (tACS).
    Haslacher D; Narang A; Sokoliuk R; Cavallo A; Reber P; Nasr K; Santarnecchi E; Soekadar SR
    Neuroimage; 2023 Jul; 275():120187. PubMed ID: 37230205
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Shift in lateralization during illusory self-motion: EEG responses to visual flicker at 10 Hz and frequency-specific modulation by tACS.
    Dowsett J; Herrmann CS; Dieterich M; Taylor PCJ
    Eur J Neurosci; 2020 Apr; 51(7):1657-1675. PubMed ID: 31408562
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Signal-Space Projection Suppresses the tACS Artifact in EEG Recordings.
    Vosskuhl J; Mutanen TP; Neuling T; Ilmoniemi RJ; Herrmann CS
    Front Hum Neurosci; 2020; 14():536070. PubMed ID: 33390915
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Removal of Gross Artifacts of Transcranial Alternating Current Stimulation in Simultaneous EEG Monitoring.
    Kohli S; Casson AJ
    Sensors (Basel); 2019 Jan; 19(1):. PubMed ID: 30621077
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Faith and oscillations recovered: On analyzing EEG/MEG signals during tACS.
    Neuling T; Ruhnau P; Weisz N; Herrmann CS; Demarchi G
    Neuroimage; 2017 Feb; 147():960-963. PubMed ID: 27888060
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Friends, not foes: Magnetoencephalography as a tool to uncover brain dynamics during transcranial alternating current stimulation.
    Neuling T; Ruhnau P; Fuscà M; Demarchi G; Herrmann CS; Weisz N
    Neuroimage; 2015 Sep; 118():406-13. PubMed ID: 26080310
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Facilitated Event-Related Power Modulations during Transcranial Alternating Current Stimulation (tACS) Revealed by Concurrent tACS-MEG.
    Kasten FH; Maess B; Herrmann CS
    eNeuro; 2018; 5(3):. PubMed ID: 30073188
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Targeting alpha-band oscillations in a cortical model with amplitude-modulated high-frequency transcranial electric stimulation.
    Negahbani E; Kasten FH; Herrmann CS; Fröhlich F
    Neuroimage; 2018 Jun; 173():3-12. PubMed ID: 29427848
    [TBL] [Abstract][Full Text] [Related]  

  • 12. tACS facilitates flickering driving by boosting steady-state visual evoked potentials.
    Liu B; Yan X; Chen X; Wang Y; Gao X
    J Neural Eng; 2021 Dec; 18(6):. PubMed ID: 34962233
    [No Abstract]   [Full Text] [Related]  

  • 13. Concurrent Electroencephalography Recording During Transcranial Alternating Current Stimulation (tACS).
    Fehér KD; Morishima Y
    J Vis Exp; 2016 Jan; (107):e53527. PubMed ID: 26862814
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcranial Alternating Current Stimulation Alters Auditory Steady-State Oscillatory Rhythms and Their Cross-Frequency Couplings.
    de la Salle S; Choueiry J; Payumo M; Devlin M; Noel C; Abozmal A; Hyde M; Baysarowich R; Duncan B; Knott V
    Clin EEG Neurosci; 2024 May; 55(3):329-339. PubMed ID: 37306065
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Entrainment of brain oscillations by transcranial alternating current stimulation.
    Helfrich RF; Schneider TR; Rach S; Trautmann-Lengsfeld SA; Engel AK; Herrmann CS
    Curr Biol; 2014 Feb; 24(3):333-9. PubMed ID: 24461998
    [TBL] [Abstract][Full Text] [Related]  

  • 16. External induction and stabilization of brain oscillations in the human.
    Hosseinian T; Yavari F; Biagi MC; Kuo MF; Ruffini G; Nitsche MA; Jamil A
    Brain Stimul; 2021; 14(3):579-587. PubMed ID: 33781955
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of 10 Hz and 20 Hz Transcranial Alternating Current Stimulation on Automatic Motor Control.
    Cappon D; D'Ostilio K; Garraux G; Rothwell J; Bisiacchi P
    Brain Stimul; 2016; 9(4):518-24. PubMed ID: 27038707
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Amplitude modulated transcranial alternating current stimulation (AM-TACS) efficacy evaluation via phosphene induction.
    Thiele C; Zaehle T; Haghikia A; Ruhnau P
    Sci Rep; 2021 Nov; 11(1):22245. PubMed ID: 34782626
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Machine learning validation of EEG+tACS artefact removal.
    Kohli S; Casson AJ
    J Neural Eng; 2020 Jan; 17(1):016034. PubMed ID: 31739290
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Alpha Power Increase After Transcranial Alternating Current Stimulation at Alpha Frequency (α-tACS) Reflects Plastic Changes Rather Than Entrainment.
    Vossen A; Gross J; Thut G
    Brain Stimul; 2015; 8(3):499-508. PubMed ID: 25648377
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.