BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1648 related articles for article (PubMed ID: 33951060)

  • 61. A New Method to Detect Variants of SARS-CoV-2 Using Reverse Transcription Loop-Mediated Isothermal Amplification Combined with a Bioluminescent Assay in Real Time (RT-LAMP-BART).
    Iijima T; Sakai J; Kanamori D; Ando S; Nomura T; Tisi L; Kilgore PE; Percy N; Kohase H; Hayakawa S; Maesaki S; Hoshino T; Seki M
    Int J Mol Sci; 2023 Jun; 24(13):. PubMed ID: 37445876
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Saliva as alternative to naso-oropharyngeal swab for SARS-CoV-2 detection by RT-qPCR: a multicenter cross-sectional diagnostic validation study.
    Tee ML; Abrilla AA; Tee CA; Dalmacio LMM; Villaflor VJP; Abubakar AA; Tagayuna PY; Aquino SSC; Bernardo VAL; Matias RR
    Sci Rep; 2022 Jul; 12(1):12612. PubMed ID: 35871257
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Clinical Evaluation of Self-Collected Saliva by Quantitative Reverse Transcription-PCR (RT-qPCR), Direct RT-qPCR, Reverse Transcription-Loop-Mediated Isothermal Amplification, and a Rapid Antigen Test To Diagnose COVID-19.
    Nagura-Ikeda M; Imai K; Tabata S; Miyoshi K; Murahara N; Mizuno T; Horiuchi M; Kato K; Imoto Y; Iwata M; Mimura S; Ito T; Tamura K; Kato Y
    J Clin Microbiol; 2020 Aug; 58(9):. PubMed ID: 32636214
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Automated sample-to-answer centrifugal microfluidic system for rapid molecular diagnostics of SARS-CoV-2.
    Malic L; Brassard D; Da Fonte D; Nassif C; Mounier M; Ponton A; Geissler M; Shiu M; Morton KJ; Veres T
    Lab Chip; 2022 Aug; 22(17):3157-3171. PubMed ID: 35670202
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Essential properties and pitfalls of colorimetric Reverse Transcription Loop-mediated Isothermal Amplification as a point-of-care test for SARS-CoV-2 diagnosis.
    de Oliveira Coelho B; Sanchuki HBS; Zanette DL; Nardin JM; Morales HMP; Fornazari B; Aoki MN; Blanes L
    Mol Med; 2021 Mar; 27(1):30. PubMed ID: 33771097
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Optimization and validation of RT-LAMP assay for diagnosis of SARS-CoV2 including the globally dominant Delta variant.
    Jamwal VL; Kumar N; Bhat R; Jamwal PS; Singh K; Dogra S; Kulkarni A; Bhadra B; Shukla MR; Saran S; Dasgupta S; Vishwakarma RA; Gandhi SG
    Virol J; 2021 Aug; 18(1):178. PubMed ID: 34461941
    [TBL] [Abstract][Full Text] [Related]  

  • 67. CLEVER assay: A visual and rapid RNA extraction-free detection of SARS-CoV-2 based on CRISPR-Cas integrated RT-LAMP technology.
    Bhatt A; Fatima Z; Ruwali M; Misra CS; Rangu SS; Rath D; Rattan A; Hameed S
    J Appl Microbiol; 2022 Aug; 133(2):410-421. PubMed ID: 35396760
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Point-of-care bulk testing for SARS-CoV-2 by combining hybridization capture with improved colorimetric LAMP.
    Bokelmann L; Nickel O; Maricic T; Pääbo S; Meyer M; Borte S; Riesenberg S
    Nat Commun; 2021 Mar; 12(1):1467. PubMed ID: 33674580
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Validation of a rapid, saliva-based, and ultra-sensitive SARS-CoV-2 screening system for pandemic-scale infection surveillance.
    Dewhurst RE; Heinrich T; Watt P; Ostergaard P; Marimon JM; Moreira M; Houldsworth PE; Rudrum JD; Wood D; Kõks S
    Sci Rep; 2022 Apr; 12(1):5936. PubMed ID: 35395856
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Development and comparison of novel multiple cross displacement amplification (MCDA) assays with other nucleic acid amplification methods for SARS-CoV-2 detection.
    Luu LDW; Payne M; Zhang X; Luo L; Lan R
    Sci Rep; 2021 Jan; 11(1):1873. PubMed ID: 33479389
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Rapid molecular diagnostics of COVID-19 by RT-LAMP in a centrifugal polystyrene-toner based microdevice with end-point visual detection.
    de Oliveira KG; Estrela PFN; Mendes GM; Dos Santos CA; Silveira-Lacerda EP; Duarte GRM
    Analyst; 2021 Feb; 146(4):1178-1187. PubMed ID: 33439160
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Comparison of RT-PCR, RT-LAMP, and Antigen Quantification Assays for the Detection of SARS-CoV-2.
    Tanimoto Y; Mori A; Miyamoto S; Ito E; Arikawa K; Iwamoto T
    Jpn J Infect Dis; 2022 May; 75(3):249-253. PubMed ID: 34588370
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Optimizing direct RT-LAMP to detect transmissible SARS-CoV-2 from primary nasopharyngeal swab samples.
    Dudley DM; Newman CM; Weiler AM; Ramuta MD; Shortreed CG; Heffron AS; Accola MA; Rehrauer WM; Friedrich TC; O'Connor DH
    PLoS One; 2020; 15(12):e0244882. PubMed ID: 33382861
    [TBL] [Abstract][Full Text] [Related]  

  • 74. SaliVISION: a rapid saliva-based COVID-19 screening and diagnostic test with high sensitivity and specificity.
    DeFina SM; Wang J; Yang L; Zhou H; Adams J; Cushing W; Tuohy B; Hui P; Liu C; Pham K
    Sci Rep; 2022 Apr; 12(1):5729. PubMed ID: 35388102
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Comparative evaluation of six nucleic acid amplification kits for SARS-CoV-2 RNA detection.
    Wu S; Shi X; Chen Q; Jiang Y; Zuo L; Wang L; Jiang M; Lin Y; Fang S; Peng B; Wu W; Liu H; Zhang R; Kwan PSL; Hu Q
    Ann Clin Microbiol Antimicrob; 2021 May; 20(1):38. PubMed ID: 34022903
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Colorimetric detection of SARS-CoV-2 by uracil-DNA glycosylase (UDG) reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Lai MY; Bukhari FDM; Zulkefli NZ; Ismail I; Mustapa NI; Soh TST; Hassan AH; Peariasamy KM; Lee YL; Suppiah J; Thayan R; Lau YL
    Int J Infect Dis; 2022 Jul; 120():132-134. PubMed ID: 35472524
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection.
    Inaba M; Higashimoto Y; Toyama Y; Horiguchi T; Hibino M; Iwata M; Imaizumi K; Doi Y
    Int J Infect Dis; 2021 Jun; 107():195-200. PubMed ID: 33862213
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Rapid processing of SARS-CoV-2 containing specimens for direct RT-PCR.
    Chomczynski P; Chomczynski PW; Kennedy A; Rymaszewski M; Wilfinger WW; Heiny JA; Mackey K
    PLoS One; 2021; 16(2):e0246867. PubMed ID: 33566873
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Variplex™ test system fails to reliably detect SARS-CoV-2 directly from respiratory samples without RNA extraction.
    Eckel F; Küsters F; Drossel B; Konert M; Mattes H; Schopf S
    Eur J Clin Microbiol Infect Dis; 2020 Dec; 39(12):2373-2377. PubMed ID: 32681309
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Saliva is Comparable to Nasopharyngeal Swabs for Molecular Detection of SARS-CoV-2.
    Callahan C; Ditelberg S; Dutta S; Littlehale N; Cheng A; Kupczewski K; McVay D; Riedel S; Kirby JE; Arnaout R
    Microbiol Spectr; 2021 Sep; 9(1):e0016221. PubMed ID: 34406838
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 83.