BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 33955169)

  • 1. Development of a risk prediction model of pneumothorax in percutaneous computed tomography guided transthoracic needle lung biopsy.
    Weon J; Robson S; Chan R; Ussher S
    J Med Imaging Radiat Oncol; 2021 Oct; 65(6):686-693. PubMed ID: 33955169
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: A prospective study.
    Ruud EA; Stavem K; Geitung JT; Borthne A; Søyseth V; Ashraf H
    Eur Radiol; 2021 Jun; 31(6):4243-4252. PubMed ID: 33354745
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pneumothorax after computed tomography-guided lung biopsy: Utility of immediate post-procedure computed tomography and one-hour delayed chest radiography.
    Weinand JT; du Pisanie L; Ngeve S; Commander C; Yu H
    PLoS One; 2023; 18(4):e0284145. PubMed ID: 37075048
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical Variables and Radiomics Features for Predicting Pneumothorax in Patients Undergoing CT-guided Transthoracic Core Needle Biopsy.
    Huang YS; Chen JL; Ko WC; Chang YH; Chang CH; Chang YC
    Radiol Cardiothorac Imaging; 2024 Jun; 6(3):e230278. PubMed ID: 38780426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
    Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
    Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies.
    Theilig D; Petschelt D; Mayerhofer A; Hamm B; Gebauer B; Geisel D
    Sci Rep; 2020 Jul; 10(1):10978. PubMed ID: 32620852
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate.
    O'Neill AC; McCarthy C; Ridge CA; Mitchell P; Hanrahan E; Butler M; Keane MP; Dodd JD
    Radiology; 2012 Jan; 262(1):314-9. PubMed ID: 22106349
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax.
    Appel E; Dommaraju S; Camacho A; Nakhaei M; Siewert B; Ahmed M; Brook A; Brook OR
    Eur Radiol; 2020 Nov; 30(11):6369-6375. PubMed ID: 32591892
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrathin fine-needle aspiration biopsy of the lung with transfissural approach: does it increase the risk of pneumothorax?
    Ayyappan AP; Souza CA; Seely J; Peterson R; Dennie C; Matzinger F
    AJR Am J Roentgenol; 2008 Dec; 191(6):1725-9. PubMed ID: 19020242
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pneumothorax Rate and Diagnostic Adequacy of Computed Tomography-guided Lung Nodule Biopsies Performed With 18 G Versus 20 G Needles: A Cross-Sectional Study.
    Kolderman NC; Cheti DR; Hasbrook CD; Forsyth AJ; Coffey MP; Nair GB; Al-Katib SA
    J Thorac Imaging; 2020 Jul; 35(4):265-269. PubMed ID: 32032253
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pneumothorax after CT-guided transthoracic lung biopsy: A comparison between immediate and delayed occurrence.
    Bae K; Ha JY; Jeon KN
    PLoS One; 2020; 15(8):e0238107. PubMed ID: 32834016
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of Complications of Percutaneous Transthoracic Needle Biopsy Using CT-Guidance Modalities In a Multicenter Cohort of 10568 Biopsies.
    Yoon SH; Park CM; Lee KH; Lim KY; Suh YJ; Im DJ; Hur J; Han DH; Kang MJ; Choo JY; Kim C; Kim JI; Hong H
    Korean J Radiol; 2019 Feb; 20(2):323-331. PubMed ID: 30672172
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung.
    Perl RM; Risse E; Hetzel J; Bösmüller H; Kloth C; Fritz J; Horger M
    Eur J Radiol; 2019 Jul; 116():14-20. PubMed ID: 31153555
    [TBL] [Abstract][Full Text] [Related]  

  • 16. CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan.
    Takeshita J; Masago K; Kato R; Hata A; Kaji R; Fujita S; Katakami N
    AJR Am J Roentgenol; 2015 Jan; 204(1):29-34. PubMed ID: 25539234
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does Ipsilateral-Dependent Positioning During Percutaneous Lung Biopsy Decrease the Risk of Pneumothorax?
    Leger T; Jerjir N; Gregory J; Bennani S; Freche G; Revel MP; Chassagnon G
    AJR Am J Roentgenol; 2019 Feb; 212(2):461-466. PubMed ID: 30540211
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy.
    Min L; Xu X; Song Y; Issahar BD; Wu J; Zhang L; Huang Q; Chen M
    Eur J Radiol; 2013 Jan; 82(1):187-90. PubMed ID: 23068560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Nomogram model to predict pneumothorax after computed tomography-guided coaxial core needle lung biopsy.
    Yang L; Liang T; Du Y; Guo C; Shang J; Pokharel S; Wang R; Niu G
    Eur J Radiol; 2021 Jul; 140():109749. PubMed ID: 34000599
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.