These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
168 related articles for article (PubMed ID: 33957211)
1. Triple-Row Technique Confers a Lower Retear Rate Than Standard Suture Bridge Technique in Arthroscopic Rotator Cuff Repairs. Tanaka M; Hanai H; Kotani Y; Kuratani K; Koizumi K; Hayashida K Arthroscopy; 2021 Oct; 37(10):3053-3061. PubMed ID: 33957211 [TBL] [Abstract][Full Text] [Related]
2. Arthroscopic Rotator Cuff Repair With Absorbable Sutures in the Medial-Row Anchors. Tanaka M; Hayashida K; Kobayashi A; Kakiuchi M Arthroscopy; 2015 Nov; 31(11):2099-105. PubMed ID: 26129724 [TBL] [Abstract][Full Text] [Related]
3. Repair Integrity and Retear Pattern After Arthroscopic Medial Knot-Tying After Suture-Bridge Lateral Row Rotator Cuff Repair. Takeuchi Y; Sugaya H; Takahashi N; Matsuki K; Tokai M; Morioka T; Ueda Y; Hoshika S Am J Sports Med; 2020 Aug; 48(10):2510-2517. PubMed ID: 32663065 [TBL] [Abstract][Full Text] [Related]
4. Repair integrity and functional outcome after arthroscopic rotator cuff repair: double-row versus suture-bridge technique. Kim KC; Shin HD; Lee WY; Han SC Am J Sports Med; 2012 Feb; 40(2):294-9. PubMed ID: 22074913 [TBL] [Abstract][Full Text] [Related]
5. Clinical outcomes and repair integrity after arthroscopic full-thickness rotator cuff repair: suture-bridge versus double-row modified Mason-Allen technique. Lee KW; Yang DS; Lee GS; Ma CH; Choy WS J Shoulder Elbow Surg; 2018 Nov; 27(11):1953-1959. PubMed ID: 29803504 [TBL] [Abstract][Full Text] [Related]
6. Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears. Mihata T; Watanabe C; Fukunishi K; Ohue M; Tsujimura T; Fujiwara K; Kinoshita M Am J Sports Med; 2011 Oct; 39(10):2091-8. PubMed ID: 21785001 [TBL] [Abstract][Full Text] [Related]
7. Arthroscopic rotator cuff repair using modified Mason-Allen medial row stitch: knotless versus knot-tying suture bridge technique. Rhee YG; Cho NS; Parke CS Am J Sports Med; 2012 Nov; 40(11):2440-7. PubMed ID: 23002202 [TBL] [Abstract][Full Text] [Related]
8. Modified suture-bridge technique to prevent a marginal dog-ear deformity improves structural integrity after rotator cuff repair. Ryu KJ; Kim BH; Lee Y; Lee YS; Kim JH Am J Sports Med; 2015 Mar; 43(3):597-605. PubMed ID: 25540295 [TBL] [Abstract][Full Text] [Related]
9. Comparison of repair integrity and functional outcomes for 3 arthroscopic suture bridge rotator cuff repair techniques. Kim KC; Shin HD; Cha SM; Lee WY Am J Sports Med; 2013 Feb; 41(2):271-7. PubMed ID: 23233548 [TBL] [Abstract][Full Text] [Related]
10. Arthroscopic rotator cuff repair using a suture bridge technique: is the repair integrity actually maintained? Cho NS; Lee BG; Rhee YG Am J Sports Med; 2011 Oct; 39(10):2108-16. PubMed ID: 21350064 [TBL] [Abstract][Full Text] [Related]
11. Modified double-pulley suture-bridge techniques with or without medial knot tying show comparable clinical and radiological outcomes in arthroscopic rotator cuff repair. Xu X; Liu H; Pan X; Yu H; Hu Y Knee Surg Sports Traumatol Arthrosc; 2021 Dec; 29(12):3997-4003. PubMed ID: 34417658 [TBL] [Abstract][Full Text] [Related]
12. Comparison of clinical outcome and repair integrity after arthroscopic suture-bridge and triple-row rotator cuff repairs of Fosbury flop tears. Kajita Y; Iwahori Y; Harada Y; Takahashi R; Sagami R; Deie M J Orthop Sci; 2024 May; 29(3):823-827. PubMed ID: 37236874 [TBL] [Abstract][Full Text] [Related]
13. Efficacy of bone marrow stimulation for arthroscopic knotless suture bridge rotator cuff repair: a prospective randomized controlled trial. Shibata T; Izaki T; Miyake S; Shibata Y; Yamamoto T J Shoulder Elbow Surg; 2023 May; 32(5):909-916. PubMed ID: 36796716 [TBL] [Abstract][Full Text] [Related]
14. Clinical Outcomes of Modified Mason-Allen Single-Row Repair for Bursal-Sided Partial-Thickness Rotator Cuff Tears: Comparison With the Double-Row Suture-Bridge Technique. Shin SJ; Kook SH; Rao N; Seo MJ Am J Sports Med; 2015 Aug; 43(8):1976-82. PubMed ID: 26055919 [TBL] [Abstract][Full Text] [Related]
15. Stump classification was correlated with retear in the suture-bridge and double-row repair techniques for arthroscopic rotator cuff repair. Takeuchi N; Kozono N; Nishii A; Matsuura K; Ishitani E; Onizuka T; Zaitsu Y; Okada T; Mizuki Y; Kimura T; Yuge H; Uchimura T; Iura K; Mori T; Ueda K; Miake G; Senju T; Takagishi K; Nakashima Y Knee Surg Sports Traumatol Arthrosc; 2021 Aug; 29(8):2587-2594. PubMed ID: 33459835 [TBL] [Abstract][Full Text] [Related]
16. Is the arthroscopic suture bridge technique suitable for full-thickness rotator cuff tears of any size? Lee SH; Kim JW; Kim TK; Kweon SH; Kang HJ; Kim SJ; Park JS Knee Surg Sports Traumatol Arthrosc; 2017 Jul; 25(7):2138-2146. PubMed ID: 28101634 [TBL] [Abstract][Full Text] [Related]
20. Retear Rates After Arthroscopic Single-Row, Double-Row, and Suture Bridge Rotator Cuff Repair at a Minimum of 1 Year of Imaging Follow-up: A Systematic Review. Hein J; Reilly JM; Chae J; Maerz T; Anderson K Arthroscopy; 2015 Nov; 31(11):2274-81. PubMed ID: 26188783 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]