These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 33959978)

  • 21. "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy.
    Yuan Z; Rong Y; Benedict SH; Daly ME; Qiu J; Yamamoto T
    J Appl Clin Med Phys; 2020 Jan; 21(1):88-94. PubMed ID: 31816170
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A potential to reduce pulmonary toxicity: the use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer.
    Lavrenkov K; Christian JA; Partridge M; Niotsikou E; Cook G; Parker M; Bedford JL; Brada M
    Radiother Oncol; 2007 May; 83(2):156-62. PubMed ID: 17493699
    [TBL] [Abstract][Full Text] [Related]  

  • 23. An assessment of cone beam CT in the adaptive radiotherapy planning process for non-small-cell lung cancer patients.
    Duffton A; Harrow S; Lamb C; McJury M
    Br J Radiol; 2016 Jun; 89(1062):20150492. PubMed ID: 27052681
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cone-beam CT-guided radiotherapy in the management of lung cancer: Diagnostic and therapeutic value.
    Elsayad K; Kriz J; Reinartz G; Scobioala S; Ernst I; Haverkamp U; Eich HT
    Strahlenther Onkol; 2016 Feb; 192(2):83-91. PubMed ID: 26630946
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.
    Liu C; Schild SE; Chang JY; Liao Z; Korte S; Shen J; Ding X; Hu Y; Kang Y; Keole SR; Sio TT; Wong WW; Sahoo N; Bues M; Liu W
    Int J Radiat Oncol Biol Phys; 2018 Jun; 101(2):479-489. PubMed ID: 29550033
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Esophagus sparing with IMRT in lung tumor irradiation: an EUD-based optimization technique.
    Chapet O; Thomas E; Kessler ML; Fraass BA; Ten Haken RK
    Int J Radiat Oncol Biol Phys; 2005 Sep; 63(1):179-87. PubMed ID: 16111587
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cone beam computed tomography-derived adaptive radiotherapy for radical treatment of esophageal cancer.
    Hawkins MA; Brooks C; Hansen VN; Aitken A; Tait DM
    Int J Radiat Oncol Biol Phys; 2010 Jun; 77(2):378-83. PubMed ID: 19775828
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Late-Course Adaptive Adjustment Based on Metabolic Tumor Volume Changes during Radiotherapy May Reduce Radiation Toxicity in Patients with Non-Small Cell Lung Cancer.
    Xiao L; Liu N; Zhang G; Zhang H; Gao S; Fu Z; Wang S; Yu Q; Yu J; Yuan S
    PLoS One; 2017; 12(1):e0170901. PubMed ID: 28125698
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Early Prediction of Acute Esophagitis for Adaptive Radiation Therapy.
    Alam SR; Zhang P; Zhang SY; Chen I; Rimner A; Tyagi N; Hu YC; Lu W; Yorke ED; Deasy JO; Thor M
    Int J Radiat Oncol Biol Phys; 2021 Jul; 110(3):883-892. PubMed ID: 33453309
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intensity-modulated radiotherapy for locally advanced non-small-cell lung cancer: a dose-escalation planning study.
    Lievens Y; Nulens A; Gaber MA; Defraene G; De Wever W; Stroobants S; Van den Heuvel F;
    Int J Radiat Oncol Biol Phys; 2011 May; 80(1):306-13. PubMed ID: 20888706
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
    Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
    J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cone-beam CT-derived relative stopping power map generation via deep learning for proton radiotherapy.
    Harms J; Lei Y; Wang T; McDonald M; Ghavidel B; Stokes W; Curran WJ; Zhou J; Liu T; Yang X
    Med Phys; 2020 Sep; 47(9):4416-4427. PubMed ID: 32579710
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Deformation driven Seq2Seq longitudinal tumor and organs-at-risk prediction for radiotherapy.
    Lee D; Alam SR; Jiang J; Zhang P; Nadeem S; Hu YC
    Med Phys; 2021 Sep; 48(9):4784-4798. PubMed ID: 34245602
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of atelectasis changes on tissue mass and dose during lung radiotherapy.
    Guy CL; Weiss E; Jan N; Reshko LB; Christensen GE; Hugo GD
    Med Phys; 2016 Nov; 43(11):6109. PubMed ID: 27806593
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A method of using deep learning to predict three-dimensional dose distributions for intensity-modulated radiotherapy of rectal cancer.
    Zhou J; Peng Z; Song Y; Chang Y; Pei X; Sheng L; Xu XG
    J Appl Clin Med Phys; 2020 May; 21(5):26-37. PubMed ID: 32281254
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage.
    Wang L; Hayes S; Paskalev K; Jin L; Buyyounouski MK; Ma CC; Feigenberg S
    Radiother Oncol; 2009 Jun; 91(3):314-24. PubMed ID: 19111362
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dosimetric evaluation of synthetic CT for magnetic resonance-only based radiotherapy planning of lung cancer.
    Wang H; Chandarana H; Block KT; Vahle T; Fenchel M; Das IJ
    Radiat Oncol; 2017 Jun; 12(1):108. PubMed ID: 28651599
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Functional lung avoidance and response-adaptive escalation (FLARE) RT: Multimodality plan dosimetry of a precision radiation oncology strategy.
    Lee E; Zeng J; Miyaoka RS; Saini J; Kinahan PE; Sandison GA; Wong T; Vesselle HJ; Rengan R; Bowen SR
    Med Phys; 2017 Jul; 44(7):3418-3429. PubMed ID: 28453861
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Reproducibility of the lung anatomy under active breathing coordinator control: Dosimetric consequences for scanned proton treatments.
    den Otter LA; Kaza E; Kierkels RGJ; Meijers A; Ubbels FJF; Leach MO; Collins DJ; Langendijk JA; Knopf AC
    Med Phys; 2018 Dec; 45(12):5525-5534. PubMed ID: 30229930
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A deep learning model to predict dose-volume histograms of organs at risk in radiotherapy treatment plans.
    Liu Z; Chen X; Men K; Yi J; Dai J
    Med Phys; 2020 Nov; 47(11):5467-5481. PubMed ID: 32677104
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.