163 related articles for article (PubMed ID: 33963078)
21. Short-Term Hemodynamic and Electrophysiological Effects of Cardiac Resynchronization by Left Ventricular Septal Pacing.
Salden FCWM; Luermans JGLM; Westra SW; Weijs B; Engels EB; Heckman LIB; Lamerichs LJM; Janssen MHG; Clerx KJH; Cornelussen R; Ghosh S; Prinzen FW; Vernooy K
J Am Coll Cardiol; 2020 Feb; 75(4):347-359. PubMed ID: 32000945
[TBL] [Abstract][Full Text] [Related]
22. Preferred left ventricular lead position for upgrade from right ventricular pacing to cardiac resynchronization therapy.
Ogano M; Iwasaki YK; Okada T; Tanabe J; Shimizu W; Asai K
J Cardiovasc Electrophysiol; 2023 Sep; 34(9):1925-1932. PubMed ID: 37449446
[TBL] [Abstract][Full Text] [Related]
23. Underestimation of duration of ventricular activation by 12-lead ECG compared with direct measurement of activation duration derived from implanted pacemaker leads.
Duncan AM; Lim E; Mebrate Y; Wong T; Gibson DG
Int J Cardiol; 2011 Oct; 152(1):35-42. PubMed ID: 20678820
[TBL] [Abstract][Full Text] [Related]
24. Comparison of the acute effects of right ventricular apical pacing and biventricular pacing in patients with heart failure.
Kanzaki H; Satomi K; Noda T; Shimizu W; Kamakura S; Kitaura Y; Ishizaka N; Kitakaze M
Intern Med; 2015; 54(11):1329-35. PubMed ID: 26027982
[TBL] [Abstract][Full Text] [Related]
25. Improvement of electrical synchrony in cardiac resynchronization therapy using dynamic atrioventricular delay programming and multipoint pacing.
Schiedat F; Mijic D; Karosiene Z; Bogossian H; Zarse M; Lemke B; Hanefeld C; Mügge A; Kloppe A
Pacing Clin Electrophysiol; 2021 Dec; 44(12):1963-1971. PubMed ID: 34586643
[TBL] [Abstract][Full Text] [Related]
26. Ventricular activation patterns during intrinsic conduction and right ventricular pacing in cardiac resynchronization therapy patients.
O'Donnell D; Manyam H; Pappone C; Park SJ; Leclercq C; Lunati M; Lercher P; Rordorf R; Landolina M; Badie N; McSpadden LC; Ryu K; Mangual JO; Singh JP; Varma N; Niazi IK
Pacing Clin Electrophysiol; 2021 Oct; 44(10):1663-1670. PubMed ID: 34319603
[TBL] [Abstract][Full Text] [Related]
27. The paced electrocardiogram cannot be used to identify left and right ventricular pacing sites in cardiac resynchronization therapy: validation by cardiac computed tomography.
Sommer A; Kronborg MB; Witt CT; Nørgaard BL; Nielsen JC
Europace; 2015 Mar; 17(3):432-8. PubMed ID: 25480941
[TBL] [Abstract][Full Text] [Related]
28. Acute echocardiographic optimization of multiple stimulation configurations of cardiac resynchronization therapy through quadripolar left ventricular pacing: a tailored approach.
Calò L; Martino A; de Ruvo E; Minati M; Fratini S; Rebecchi M; Lanzillo C; Fagagnini A; Borrelli A; De Luca L; Sciarra L
Am Heart J; 2014 Apr; 167(4):546-54. PubMed ID: 24655704
[TBL] [Abstract][Full Text] [Related]
29. Impact of synchronous atrioventricular delay optimization on left ventricle flow force angle evaluated by echocardiographic particle image velocimetry.
Bianchi V; Martiniello AR; Mangual J; Tavoletta V; Pedrizzetti G; Tonti G; Caso VM; Caso P; D'Onofrio A
J Interv Card Electrophysiol; 2022 Jan; 63(1):1-8. PubMed ID: 33474704
[TBL] [Abstract][Full Text] [Related]
30. Biventricular pacing improves the blunted force-frequency relation present during univentricular pacing in patients with heart failure and conduction delay.
Vollmann D; Lüthje L; Schott P; Hasenfuss G; Unterberg-Buchwald C
Circulation; 2006 Feb; 113(7):953-9. PubMed ID: 16476849
[TBL] [Abstract][Full Text] [Related]
31. Changes in the optimal cardiac resynchronization therapy pacing configuration during physiologic stress.
Atwater BD; Jones WS; Loring Z; Friedman DJ
J Electrocardiol; 2020; 62():124-128. PubMed ID: 32866910
[TBL] [Abstract][Full Text] [Related]
32. Atrioventricular optimization in cardiac resynchronization therapy with quadripolar leads: should we optimize every pacing configuration including multi-point pacing?
van Everdingen WM; Zweerink A; Salden OAE; Cramer MJ; Doevendans PA; van Rossum AC; Prinzen FW; Vernooy K; Allaart CP; Meine M
Europace; 2019 Jan; 21(1):e11-e19. PubMed ID: 30052906
[TBL] [Abstract][Full Text] [Related]
33. Electrical and mechanical components of dyssynchrony in heart failure patients with normal QRS duration and left bundle-branch block: impact of left and biventricular pacing.
Turner MS; Bleasdale RA; Vinereanu D; Mumford CE; Paul V; Fraser AG; Frenneaux MP
Circulation; 2004 Jun; 109(21):2544-9. PubMed ID: 15148267
[TBL] [Abstract][Full Text] [Related]
34. Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients.
Pappone C; Ćalović Ž; Vicedomini G; Cuko A; McSpadden LC; Ryu K; Romano E; Saviano M; Baldi M; Pappone A; Ciaccio C; Giannelli L; Ionescu B; Petretta A; Vitale R; Fundaliotis A; Tavazzi L; Santinelli V
Heart Rhythm; 2014 Mar; 11(3):394-401. PubMed ID: 24291411
[TBL] [Abstract][Full Text] [Related]
35. Ventricular activation sequence during left ventricular pacing promotes QRS complex oversensing in the atrial channel.
Jastrzebski M
Pacing Clin Electrophysiol; 2011 Dec; 34(12):1682-6. PubMed ID: 21954967
[TBL] [Abstract][Full Text] [Related]
36. Bifocal left ventricular stimulation or the optimal left ventricular stimulation site in cardiac resynchronization therapy: a pressure-volume loop study.
de Roest GJ; Wu L; de Cock CC; Delnoy PP; Hendriks ML; van Rossum AC; Allaart CP
Europace; 2016 Jul; 18(7):1030-7. PubMed ID: 26498161
[TBL] [Abstract][Full Text] [Related]
37. The effect of left ventricular electrical delay on the acute hemodynamic response with cardiac resynchronization therapy.
Gold MR; Leman RB; Wold N; Sturdivant JL; Yu Y
J Cardiovasc Electrophysiol; 2014 Jun; 25(6):624-30. PubMed ID: 24446891
[TBL] [Abstract][Full Text] [Related]
38. Long-term reverse remodeling by cardiac resynchronization therapy with MultiPoint Pacing: A feasibility study of noninvasive hemodynamics-guided device programming.
Lercher P; Lunati M; Rordorf R; Landolina M; Badie N; Qu F; Casset C; Ryu K; Ghio S; Singh JP; Leclercq C
Heart Rhythm; 2018 Dec; 15(12):1766-1774. PubMed ID: 29940305
[TBL] [Abstract][Full Text] [Related]
39. RV electrical activation in heart failure during right, left, and biventricular pacing.
Varma N; Jia P; Ramanathan C; Rudy Y
JACC Cardiovasc Imaging; 2010 Jun; 3(6):567-75. PubMed ID: 20541711
[TBL] [Abstract][Full Text] [Related]
40. Cardiac resynchronization therapy non-responder to responder conversion rate in the more response to cardiac resynchronization therapy with MultiPoint Pacing (MORE-CRT MPP) study: results from Phase I.
Leclercq C; Burri H; Curnis A; Delnoy PP; Rinaldi CA; Sperzel J; Lee K; Calò L; Vicentini A; Concha JF; Thibault B
Eur Heart J; 2019 Sep; 40(35):2979-2987. PubMed ID: 30859220
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]