BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

295 related articles for article (PubMed ID: 33974885)

  • 41. Target miss using PTV-based IMRT compared to robust optimization via coverage probability concept in prostate cancer.
    Outaggarts Z; Wegener D; Berger B; Zips D; Paulsen F; Bleif M; Thorwarth D; Alber M; Dohm O; Müller AC
    Acta Oncol; 2020 Aug; 59(8):911-917. PubMed ID: 32436467
    [No Abstract]   [Full Text] [Related]  

  • 42. Potential proton and photon dose degradation in advanced head and neck cancer patients by intratherapy changes.
    Stützer K; Jakobi A; Bandurska-Luque A; Barczyk S; Arnsmeyer C; Löck S; Richter C
    J Appl Clin Med Phys; 2017 Nov; 18(6):104-113. PubMed ID: 28921843
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Is there an advantage in designing adapted, patient-specific PTV margins in intensity modulated proton beam therapy for prostate cancer?
    Góra J; Stock M; Lütgendorf-Caucig C; Georg D
    Int J Radiat Oncol Biol Phys; 2013 Mar; 85(3):881-8. PubMed ID: 22818417
    [TBL] [Abstract][Full Text] [Related]  

  • 44. On the interplay effects with proton scanning beams in stage III lung cancer.
    Li Y; Kardar L; Li X; Li H; Cao W; Chang JY; Liao L; Zhu RX; Sahoo N; Gillin M; Liao Z; Komaki R; Cox JD; Lim G; Zhang X
    Med Phys; 2014 Feb; 41(2):021721. PubMed ID: 24506612
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Robust mixed electron-photon radiation therapy optimization.
    Renaud MA; Serban M; Seuntjens J
    Med Phys; 2019 Mar; 46(3):1384-1396. PubMed ID: 30628079
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Importance of protocol target definition on the ability to spare normal tissue: an IMRT and 3D-CRT planning comparison for intraorbital tumors.
    Hein PA; Gladstone DJ; Bellerive MR; Hug EB
    Int J Radiat Oncol Biol Phys; 2005 Aug; 62(5):1540-8. PubMed ID: 16029816
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Four-dimensional Plan Optimization for the Treatment of Lung Tumors Using Pencil-beam Scanning Proton Radiotherapy.
    Cummings D; Tang S; Ichter W; Wang P; Sturgeon JD; Lee AK; Chang C
    Cureus; 2018 Aug; 10(8):e3192. PubMed ID: 30402360
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Anatomical robust optimization to account for nasal cavity filling variation during intensity-modulated proton therapy: a comparison with conventional and adaptive planning strategies.
    van de Water S; Albertini F; Weber DC; Heijmen BJM; Hoogeman MS; Lomax AJ
    Phys Med Biol; 2018 Jan; 63(2):025020. PubMed ID: 29160775
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Experimental validation of a 4D dynamic dose calculation model for proton pencil beam scanning without spot time stamp considering free-breathing motion.
    Tominaga Y; Oita M; Miyata J; Kato T
    Med Phys; 2024 Jan; 51(1):566-578. PubMed ID: 37672227
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A study of the beam-specific interplay effect in proton pencil beam scanning delivery in lung cancer.
    Kang M; Huang S; Solberg TD; Mayer R; Thomas A; Teo BK; McDonough JE; Simone CB; Lin L
    Acta Oncol; 2017 Apr; 56(4):531-540. PubMed ID: 28358666
    [TBL] [Abstract][Full Text] [Related]  

  • 51. 4D strategies for lung tumors treated with hypofractionated scanning proton beam therapy: Dosimetric impact and robustness to interplay effects.
    Mastella E; Molinelli S; Pella A; Vai A; Maestri D; Vitolo V; Baroni G; Valvo F; Ciocca M
    Radiother Oncol; 2020 May; 146():213-220. PubMed ID: 32222489
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A Monte-Carlo study to assess the effect of 1.5 T magnetic fields on the overall robustness of pencil-beam scanning proton radiotherapy plans for prostate cancer.
    Kurz C; Landry G; Resch AF; Dedes G; Kamp F; Ganswindt U; Belka C; Raaymakers BW; Parodi K
    Phys Med Biol; 2017 Oct; 62(21):8470-8482. PubMed ID: 29047455
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Highly Conformal Craniospinal Radiotherapy Techniques Can Underdose the Cranial Clinical Target Volume if Leptomeningeal Extension through Skull Base Exit Foramina is not Contoured.
    Noble DJ; Ajithkumar T; Lambert J; Gleeson I; Williams MV; Jefferies SJ
    Clin Oncol (R Coll Radiol); 2017 Jul; 29(7):439-447. PubMed ID: 28318880
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Small spot size versus large spot size: Effect on plan quality for lung cancer in pencil beam scanning proton therapy.
    Rana S; Rosenfeld AB
    J Appl Clin Med Phys; 2022 Feb; 23(2):e13512. PubMed ID: 34989458
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A comprehensive dosimetric study of pancreatic cancer treatment using three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated radiation therapy (VMAT), and passive-scattering and modulated-scanning proton therapy (PT).
    Ding X; Dionisi F; Tang S; Ingram M; Hung CY; Prionas E; Lichtenwalner P; Butterwick I; Zhai H; Yin L; Lin H; Kassaee A; Avery S
    Med Dosim; 2014; 39(2):139-45. PubMed ID: 24661778
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Mitigation of motion effects in pencil-beam scanning - Impact of repainting on 4D robustly optimized proton treatment plans for hepatocellular carcinoma.
    Siregar H; Bäumer C; Blanck O; Chan M; Engwall E; Plaude S; Spaan B; Timmermann B; Wulff J
    Z Med Phys; 2022 Feb; 32(1):63-73. PubMed ID: 33131995
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A motion model-guided 4D dose reconstruction for pencil beam scanned proton therapy.
    Duetschler A; Huang L; Fattori G; Meier G; Bula C; Hrbacek J; Safai S; Weber DC; Lomax AJ; Zhang Y
    Phys Med Biol; 2023 May; 68(11):. PubMed ID: 37172608
    [No Abstract]   [Full Text] [Related]  

  • 58. Three-dimensional versus four-dimensional dose calculation for volumetric modulated arc therapy of hypofractionated treatments.
    Ehrbar S; Lang S; Stieb S; Riesterer O; Stark LS; Guckenberger M; Klöck S
    Z Med Phys; 2016 Mar; 26(1):45-53. PubMed ID: 26187810
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Dynamic simulation of motion effects in IMAT lung SBRT.
    Zou W; Yin L; Shen J; Corradetti MN; Kirk M; Munbodh R; Fang P; Jabbour SK; Simone CB; Yue NJ; Rengan R; Teo BK
    Radiat Oncol; 2014 Nov; 9():225. PubMed ID: 25365935
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.
    Gu W; O'Connor D; Nguyen D; Yu VY; Ruan D; Dong L; Sheng K
    Med Phys; 2018 Apr; 45(4):1338-1350. PubMed ID: 29394454
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.