219 related articles for article (PubMed ID: 33986721)
1. Gray Matter Sampling Differences Between Subdural Electrodes and Stereoelectroencephalography Electrodes.
Tantawi M; Miao J; Matias C; Skidmore CT; Sperling MR; Sharan AD; Wu C
Front Neurol; 2021; 12():669406. PubMed ID: 33986721
[No Abstract] [Full Text] [Related]
2. Postoperative outcomes following pediatric intracranial electrode monitoring: A case for stereoelectroencephalography (SEEG).
Kim LH; Parker JJ; Ho AL; Pendharkar AV; Sussman ES; Halpern CH; Porter B; Grant GA
Epilepsy Behav; 2020 Mar; 104(Pt A):106905. PubMed ID: 32028127
[TBL] [Abstract][Full Text] [Related]
3. Contemporaneous evaluation of patient experience, surgical strategy, and seizure outcomes in patients undergoing stereoelectroencephalography or subdural electrode monitoring.
Kim LH; Parker JJ; Ho AL; Feng AY; Kumar KK; Chen KS; Ojukwu DI; Shuer LM; Grant GA; Graber KD; Halpern CH
Epilepsia; 2021 Jan; 62(1):74-84. PubMed ID: 33236777
[TBL] [Abstract][Full Text] [Related]
4. Analysis of Morbidity and Outcomes Associated With Use of Subdural Grids vs Stereoelectroencephalography in Patients With Intractable Epilepsy.
Tandon N; Tong BA; Friedman ER; Johnson JA; Von Allmen G; Thomas MS; Hope OA; Kalamangalam GP; Slater JD; Thompson SA
JAMA Neurol; 2019 Jun; 76(6):672-681. PubMed ID: 30830149
[TBL] [Abstract][Full Text] [Related]
5. Patient phenotypes and clinical outcomes in invasive monitoring for epilepsy: An individual patient data meta-analysis.
Remick M; Ibrahim GM; Mansouri A; Abel TJ
Epilepsy Behav; 2020 Jan; 102():106652. PubMed ID: 31770717
[TBL] [Abstract][Full Text] [Related]
6. Comparison of subdural grid and stereoelectroencephalography in a cohort of pediatric patients.
Talai A; Eschbach K; Stence NV; Palmer C; Bird W; Alexander A; O'Neill BR; Chapman KE; Joshi C
Epilepsy Res; 2021 Nov; 177():106758. PubMed ID: 34530304
[TBL] [Abstract][Full Text] [Related]
7. Indications, technique, and safety profile of insular stereoelectroencephalography electrode implantation in medically intractable epilepsy.
Alomar S; Mullin JP; Smithason S; Gonzalez-Martinez J
J Neurosurg; 2018 Apr; 128(4):1147-1157. PubMed ID: 28621621
[TBL] [Abstract][Full Text] [Related]
8. Subdural electrodes versus stereoelectroencephalography for pediatric epileptogenic zone localization: a retrospective cohort study.
Remick M; Akwayena E; Harford E; Chilukuri A; White GE; Abel TJ
Neurosurg Focus; 2022 Oct; 53(4):E4. PubMed ID: 36183187
[TBL] [Abstract][Full Text] [Related]
9. Comparing electrical stimulation functional mapping with subdural electrodes and stereoelectroencephalography.
Aungaroon G; Vedala K; Byars AW; Ervin B; Rozhkov L; Horn PS; Ihnen SKZ; Holland KD; Tenney JR; Kremer K; Fong SL; Lin N; Liu W; Arthur TM; Fujiwara H; Skoch J; Leach JL; Mangano FT; Greiner HM; Arya R
Epilepsia; 2023 Jun; 64(6):1527-1540. PubMed ID: 36872854
[TBL] [Abstract][Full Text] [Related]
10. Method of invasive monitoring in epilepsy surgery and seizure freedom and morbidity: A systematic review.
Yan H; Katz JS; Anderson M; Mansouri A; Remick M; Ibrahim GM; Abel TJ
Epilepsia; 2019 Sep; 60(9):1960-1972. PubMed ID: 31423575
[TBL] [Abstract][Full Text] [Related]
11. Stereoelectroencephalography in epilepsy, cognitive neurophysiology, and psychiatric disease: safety, efficacy, and place in therapy.
Youngerman BE; Khan FA; McKhann GM
Neuropsychiatr Dis Treat; 2019; 15():1701-1716. PubMed ID: 31303757
[TBL] [Abstract][Full Text] [Related]
12. Depth versus surface: A critical review of subdural and depth electrodes in intracranial electroencephalographic studies.
Wu S; Issa NP; Rose SL; Haider HA; Nordli DR; Towle VL; Warnke PC; Tao JX
Epilepsia; 2024 May; ():. PubMed ID: 38722693
[TBL] [Abstract][Full Text] [Related]
13. Computer-assisted planning for the insertion of stereoelectroencephalography electrodes for the investigation of drug-resistant focal epilepsy: an external validation study.
Vakharia VN; Sparks R; Rodionov R; Vos SB; Dorfer C; Miller J; Nilsson D; Tisdall M; Wolfsberger S; McEvoy AW; Miserocchi A; Winston GP; O'Keeffe AG; Ourselin S; Duncan JS
J Neurosurg; 2018 Apr; 130(2):601-610. PubMed ID: 29652234
[TBL] [Abstract][Full Text] [Related]
14. IntrAnat Electrodes: A Free Database and Visualization Software for Intracranial Electroencephalographic Data Processed for Case and Group Studies.
Deman P; Bhattacharjee M; Tadel F; Job AS; Rivière D; Cointepas Y; Kahane P; David O
Front Neuroinform; 2018; 12():40. PubMed ID: 30034332
[TBL] [Abstract][Full Text] [Related]
15. Stereoelectroencephalography for continuous two-dimensional cursor control in a brain-machine interface.
Vadera S; Marathe AR; Gonzalez-Martinez J; Taylor DM
Neurosurg Focus; 2013 Jun; 34(6):E3. PubMed ID: 23724837
[TBL] [Abstract][Full Text] [Related]
16. Stereoelectroencephalography versus Subdural Electrode Implantation to Determine Whether Patients with Drug-resistant Epilepsy Are Candidates for Epilepsy Surgery.
Fiani B; Jarrah R; Doan T; Shields J; Houston R; Sarno E
Neurol Med Chir (Tokyo); 2021 Jun; 61(6):347-355. PubMed ID: 33967179
[TBL] [Abstract][Full Text] [Related]
17. Robot-assisted stereoencephalography vs subdural electrodes in the evaluation of temporal lobe epilepsy.
Gorbachuk M; Machetanz K; Weinbrenner E; Grimm F; Wuttke TV; Wang S; Ethofer S; Tatagiba M; Rona S; Honegger J; Naros G
Epilepsia Open; 2023 Sep; 8(3):888-897. PubMed ID: 37149851
[TBL] [Abstract][Full Text] [Related]
18. Safety and efficacy of stereoelectroencephalography in pediatric focal epilepsy: a single-center experience.
Goldstein HE; Youngerman BE; Shao B; Akman CI; Mandel AM; McBrian DK; Riviello JJ; Sheth SA; McKhann GM; Feldstein NA
J Neurosurg Pediatr; 2018 Oct; 22(4):444-452. PubMed ID: 30028270
[TBL] [Abstract][Full Text] [Related]
19. The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients.
Serletis D; Bulacio J; Bingaman W; Najm I; González-Martínez J
J Neurosurg; 2014 Nov; 121(5):1239-46. PubMed ID: 25148007
[TBL] [Abstract][Full Text] [Related]
20. Stereoelectroencephalography Versus Subdural Strip Electrode Implantations: Feasibility, Complications, and Outcomes in 500 Intracranial Monitoring Cases for Drug-Resistant Epilepsy.
Joswig H; Lau JC; Abdallat M; Parrent AG; MacDougall KW; McLachlan RS; Burneo JG; Steven DA
Neurosurgery; 2020 Jul; 87(1):E23-E30. PubMed ID: 32357217
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]