475 related articles for article (PubMed ID: 33988849)
21. Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography: A Systematic Phantom and Patient Study.
Sartoretti T; Mergen V; Higashigaito K; Eberhard M; Alkadhi H; Euler A
Invest Radiol; 2022 Jul; 57(7):488-493. PubMed ID: 35136003
[TBL] [Abstract][Full Text] [Related]
22. Image Quality and Radiation Dose of CTPA With Iodine Maps: A Prospective Randomized Study of High-Pitch Mode Photon-Counting Detector CT Versus Energy-Integrating Detector CT.
Pannenbecker P; Heidenreich JF; Grunz JP; Huflage H; Gruschwitz P; Patzer TS; Feldle P; Bley TA; Petritsch B
AJR Am J Roentgenol; 2024 Feb; 222(2):e2330154. PubMed ID: 37966036
[No Abstract] [Full Text] [Related]
23. The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.
Krauss B; Grant KL; Schmidt BT; Flohr TG
Invest Radiol; 2015 Feb; 50(2):114-8. PubMed ID: 25373305
[TBL] [Abstract][Full Text] [Related]
24. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.
Yu Z; Leng S; Jorgensen SM; Li Z; Gutjahr R; Chen B; Halaweish AF; Kappler S; Yu L; Ritman EL; McCollough CH
Phys Med Biol; 2016 Feb; 61(4):1572-95. PubMed ID: 26835839
[TBL] [Abstract][Full Text] [Related]
25. Photon-Counting Detector CT With Denoising for Imaging of the Osseous Pelvis at Low Radiation Doses: A Phantom Study.
Marcus RP; Nagy DA; Feuerriegel GC; Anhaus J; Nanz D; Sutter R
AJR Am J Roentgenol; 2024 Jan; 222(1):e2329765. PubMed ID: 37646387
[No Abstract] [Full Text] [Related]
26. Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT.
Bette SJ; Braun FM; Haerting M; Decker JA; Luitjens JH; Scheurig-Muenkler C; Kroencke TJ; Schwarz F
Eur Radiol; 2022 May; 32(5):2930-2936. PubMed ID: 34936011
[TBL] [Abstract][Full Text] [Related]
27. Dual-source multienergy CT with triple or quadruple x-ray beams.
Yu L; Ren L; Li Z; Leng S; McCollough CH
J Med Imaging (Bellingham); 2018 Jul; 5(3):033502. PubMed ID: 30065949
[TBL] [Abstract][Full Text] [Related]
28. Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising.
Koons EK; Thorne JE; Huber NR; Chang S; Rajendran K; McCollough CH; Leng S
Med Phys; 2023 Jul; 50(7):4173-4181. PubMed ID: 37069830
[TBL] [Abstract][Full Text] [Related]
29. Accuracy of Nodule Volume and Airway Wall Thickness Measurement Using Low-Dose Chest CT on a Photon-Counting Detector CT Scanner.
Dunning CAS; Marsh JF; Winfree T; Rajendran K; Leng S; Levin DL; Johnson TF; Fletcher JG; McCollough CH; Yu L
Invest Radiol; 2023 Apr; 58(4):283-292. PubMed ID: 36525385
[TBL] [Abstract][Full Text] [Related]
30. First Clinical Photon-counting Detector CT System: Technical Evaluation.
Rajendran K; Petersilka M; Henning A; Shanblatt ER; Schmidt B; Flohr TG; Ferrero A; Baffour F; Diehn FE; Yu L; Rajiah P; Fletcher JG; Leng S; McCollough CH
Radiology; 2022 Apr; 303(1):130-138. PubMed ID: 34904876
[TBL] [Abstract][Full Text] [Related]
31. A unified material decomposition framework for quantitative dual- and triple-energy CT imaging.
Zhao W; Vernekohl D; Han F; Han B; Peng H; Yang Y; Xing L; Min JK
Med Phys; 2018 Jul; 45(7):2964-2977. PubMed ID: 29679500
[TBL] [Abstract][Full Text] [Related]
32. Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience.
Rajendran K; Petersilka M; Henning A; Shanblatt E; Marsh J; Thorne J; Schmidt B; Flohr T; Fletcher J; McCollough C; Leng S
Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34271558
[TBL] [Abstract][Full Text] [Related]
33. Characterization of Urinary Stone Composition by Use of Whole-body, Photon-counting Detector CT.
Ferrero A; Gutjahr R; Halaweish AF; Leng S; McCollough CH
Acad Radiol; 2018 Oct; 25(10):1270-1276. PubMed ID: 29454545
[TBL] [Abstract][Full Text] [Related]
34. Three-Material Decomposition in Multi-energy CT: Impact of Prior Information on Noise and Bias.
Ren L; McCollough CH; Yu L
Proc SPIE Int Soc Opt Eng; 2018 Mar; 10573():. PubMed ID: 29674804
[TBL] [Abstract][Full Text] [Related]
35. Photon-Counting CT: High-Resolution Imaging of Coronary Stents.
Mannil M; Hickethier T; von Spiczak J; Baer M; Henning A; Hertel M; Schmidt B; Flohr T; Maintz D; Alkadhi H
Invest Radiol; 2018 Mar; 53(3):143-149. PubMed ID: 28945655
[TBL] [Abstract][Full Text] [Related]
36. Optimizing dual-energy CT technique for iodine-based contrast-to-noise ratio, a theoretical study.
Terzioglu F; Sidky EY; Phillips JP; Reiser IS; Bal G; Pan X
Med Phys; 2024 Apr; 51(4):2871-2881. PubMed ID: 38436473
[TBL] [Abstract][Full Text] [Related]
37. Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies.
Zhan X; Zhang R; Niu X; Hein I; Budden B; Wu S; Markov N; Clarke C; Qiang Y; Taguchi H; Nomura K; Muramatsu Y; Yu Z; Kobayashi T; Thompson R; Miyazaki H; Nakai H
Phys Med Biol; 2023 Aug; 68(17):. PubMed ID: 37506710
[No Abstract] [Full Text] [Related]
38. Liver Iodine Quantification With Photon-Counting Detector CT: Accuracy in an Abdominal Phantom and Feasibility in Patients.
Sartoretti T; Mergen V; Jungblut L; Alkadhi H; Euler A
Acad Radiol; 2023 Mar; 30(3):461-469. PubMed ID: 35644755
[TBL] [Abstract][Full Text] [Related]
39. Quantification of liver fat in the presence of iron and iodine: an ex-vivo dual-energy CT study.
Fischer MA; Gnannt R; Raptis D; Reiner CS; Clavien PA; Schmidt B; Leschka S; Alkadhi H; Goetti R
Invest Radiol; 2011 Jun; 46(6):351-8. PubMed ID: 21263329
[TBL] [Abstract][Full Text] [Related]
40. A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study.
Zhou W; Michalak GJ; Weaver JM; Gong H; Yu L; McCollough CH; Leng S
Invest Radiol; 2020 Apr; 55(4):226-232. PubMed ID: 32049691
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]