41. Effects of Plasma Treated Alumina Nanoparticles on Breakdown Strength, Partial Discharge Resistance, and Thermophysical Properties of Mineral Oil-Based Nanofluids. Saman NM; Zakaria IH; Ahmad MH; Abdul-Malek Z Materials (Basel); 2021 Jun; 14(13):. PubMed ID: 34203364 [TBL] [Abstract][Full Text] [Related]
42. A Study on the Motion Behavior of Metallic Contaminant Particles in Transformer Insulation Oil under Multiphysical Fields. Wei B; Wang Z; Qi R; Wang X; Zhao T Sensors (Basel); 2024 Aug; 24(17):. PubMed ID: 39275394 [TBL] [Abstract][Full Text] [Related]
43. Localization for Dual Partial Discharge Sources in Transformer Oil Using Pressure-Balanced Fiber-Optic Ultrasonic Sensor Array. Liu F; Shi Y; Zhang S; Wang W Sensors (Basel); 2024 Jul; 24(14):. PubMed ID: 39065847 [TBL] [Abstract][Full Text] [Related]
44. Towards Online Ageing Detection in Transformer Oil: A Review. Elele U; Nekahi A; Arshad A; Fofana I Sensors (Basel); 2022 Oct; 22(20):. PubMed ID: 36298273 [TBL] [Abstract][Full Text] [Related]
45. Mechanism Analysis of Ethanol Production from Cellulosic Insulating Paper Based on Reaction Molecular Dynamics. Fan Y; Li Y; Zhang Y; Shi K Polymers (Basel); 2022 Nov; 14(22):. PubMed ID: 36433045 [TBL] [Abstract][Full Text] [Related]
46. Development of a spectrofluorimetry-based device for determining the acetylene content in the oils of power transformers. Quintella CM; Meira M; Silva WL; Filho RG; Araújo AL; Júnior ET; Sales LJ Talanta; 2013 Dec; 117():263-7. PubMed ID: 24209339 [TBL] [Abstract][Full Text] [Related]
47. Condition Assessment of Natural Ester-Mineral Oil Mixture Due to Transformer Retrofilling via Sensing Dielectric Properties. Karaman HS; Mansour DA; Lehtonen M; Darwish MMF Sensors (Basel); 2023 Jul; 23(14):. PubMed ID: 37514734 [TBL] [Abstract][Full Text] [Related]
48. Mica/Epoxy-Composites in the Electrical Industry: Applications, Composites for Insulation, and Investigations on Failure Mechanisms for Prospective Optimizations. Andraschek N; Wanner AJ; Ebner C; Riess G Polymers (Basel); 2016 May; 8(5):. PubMed ID: 30979297 [TBL] [Abstract][Full Text] [Related]
49. Solvent cleaning of pole transformers containing PCB contaminated insulating oil. Kanbe H; Shibuya M Waste Manag; 2001; 21(4):371-80. PubMed ID: 11300537 [TBL] [Abstract][Full Text] [Related]
50. A Comparative Analysis Applied to the Partial Discharges Identification in Dry-Type Transformers by Hall and Acoustic Emission Sensors. de Castro BA; Dos Santos VV; Lucas GB; Ardila-Rey JA; Riehl RR; Andreoli AL Sensors (Basel); 2022 Feb; 22(5):. PubMed ID: 35270863 [TBL] [Abstract][Full Text] [Related]
51. Quantitative Evaluation of Thermal Ageing State of Cross-Linked Polyethylene Insulation Based on Polarization and Depolarization Current. Huang P; Yu W; Lu C; He X; Zhang Y; Liu Y; Zhou J; Liang Y Polymers (Basel); 2023 Mar; 15(5):. PubMed ID: 36904512 [TBL] [Abstract][Full Text] [Related]
52. Robust and sensitive analysis of methanol and ethanol from cellulose degradation in mineral oils. Jalbert J; Duchesne S; Rodriguez-Celis E; Tétreault P; Collin P J Chromatogr A; 2012 Sep; 1256():240-5. PubMed ID: 22885053 [TBL] [Abstract][Full Text] [Related]
53. A developed DQ control method for shunt active power filter to improve power quality in transformers. Al-Gahtani SF; Elbarbary ZMS; Irshad SM PLoS One; 2024; 19(7):e0299635. PubMed ID: 39024392 [TBL] [Abstract][Full Text] [Related]
54. Development of Acoustic Emission Sensor Optimized for Partial Discharge Monitoring in Power Transformers. Sikorski W Sensors (Basel); 2019 Apr; 19(8):. PubMed ID: 31003527 [TBL] [Abstract][Full Text] [Related]
55. Improvement of the Space Charge Suppression and Hydrophobicity Property of Cellulose Insulation Pressboard by Surface Sputtering a ZnO/PTFE Functional Film. Li Y; Hao J; Zhang J; Hou W; Liu C; Liao R Polymers (Basel); 2019 Oct; 11(10):. PubMed ID: 31623371 [TBL] [Abstract][Full Text] [Related]
56. Appropriate analysis on properties of various compositions on fluids with and without additives for liquid insulation in power system transformer applications. Karthik M; Nuvvula RSS; Dhanamjayulu C; Khan B Sci Rep; 2024 Aug; 14(1):17814. PubMed ID: 39090155 [TBL] [Abstract][Full Text] [Related]
57. Integrated On-Chip Transformers: Recent Progress in the Design, Layout, Modeling and Fabrication. Bajwa R; Yapici MK Sensors (Basel); 2019 Aug; 19(16):. PubMed ID: 31412582 [TBL] [Abstract][Full Text] [Related]
58. Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings. Srikanta Murthy A; Azis N; Jasni J; Othman ML; Mohd Yousof MF; Talib MA PLoS One; 2020; 15(10):e0240368. PubMed ID: 33035254 [TBL] [Abstract][Full Text] [Related]
59. Sustainable, Renewable and Environmental-Friendly Insulation Systems for High Voltages Applications. Rafiq M; Shafique M; Azam A; Ateeq M; Khan IA; Hussain A Molecules; 2020 Aug; 25(17):. PubMed ID: 32867078 [TBL] [Abstract][Full Text] [Related]
60. Mineral and Ester Nanofluids as Dielectric Cooling Liquid for Power Transformers. Olmo C; Méndez C; Quintanilla PJ; Ortiz F; Renedo CJ; Ortiz A Nanomaterials (Basel); 2022 Aug; 12(15):. PubMed ID: 35957155 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]